Cargando…

Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force

BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, th...

Descripción completa

Detalles Bibliográficos
Autores principales: Bochkezanian, Vanesa, Newton, Robert U., Trajano, Gabriel S., Vieira, Amilton, Pulverenti, Timothy S., Blazevich, Anthony J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414318/
https://www.ncbi.nlm.nih.gov/pubmed/28464800
http://dx.doi.org/10.1186/s12883-017-0862-x
_version_ 1783233349943296000
author Bochkezanian, Vanesa
Newton, Robert U.
Trajano, Gabriel S.
Vieira, Amilton
Pulverenti, Timothy S.
Blazevich, Anthony J.
author_facet Bochkezanian, Vanesa
Newton, Robert U.
Trajano, Gabriel S.
Vieira, Amilton
Pulverenti, Timothy S.
Blazevich, Anthony J.
author_sort Bochkezanian, Vanesa
collection PubMed
description BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before “muscle fatigue”, and the post-exercise recovery of muscle function. METHODS: Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. RESULTS: TTI increased (145.0 ± 127.7%) in STIM only for “positive responders” to the tendon vibration (8/16 subjects), but decreased in “negative responders” (−43.5 ± 25.7%). MVIC (−8.7%) and rectus femoris electromyography (RF EMG) (−16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. CONCLUSIONS: Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone.
format Online
Article
Text
id pubmed-5414318
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54143182017-05-03 Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force Bochkezanian, Vanesa Newton, Robert U. Trajano, Gabriel S. Vieira, Amilton Pulverenti, Timothy S. Blazevich, Anthony J. BMC Neurol Research Article BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before “muscle fatigue”, and the post-exercise recovery of muscle function. METHODS: Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. RESULTS: TTI increased (145.0 ± 127.7%) in STIM only for “positive responders” to the tendon vibration (8/16 subjects), but decreased in “negative responders” (−43.5 ± 25.7%). MVIC (−8.7%) and rectus femoris electromyography (RF EMG) (−16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. CONCLUSIONS: Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone. BioMed Central 2017-05-02 /pmc/articles/PMC5414318/ /pubmed/28464800 http://dx.doi.org/10.1186/s12883-017-0862-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Bochkezanian, Vanesa
Newton, Robert U.
Trajano, Gabriel S.
Vieira, Amilton
Pulverenti, Timothy S.
Blazevich, Anthony J.
Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title_full Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title_fullStr Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title_full_unstemmed Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title_short Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
title_sort effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (nmes) on the decline and recovery of muscle force
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414318/
https://www.ncbi.nlm.nih.gov/pubmed/28464800
http://dx.doi.org/10.1186/s12883-017-0862-x
work_keys_str_mv AT bochkezanianvanesa effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce
AT newtonrobertu effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce
AT trajanogabriels effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce
AT vieiraamilton effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce
AT pulverentitimothys effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce
AT blazevichanthonyj effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce