Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force
BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, th...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414318/ https://www.ncbi.nlm.nih.gov/pubmed/28464800 http://dx.doi.org/10.1186/s12883-017-0862-x |
_version_ | 1783233349943296000 |
---|---|
author | Bochkezanian, Vanesa Newton, Robert U. Trajano, Gabriel S. Vieira, Amilton Pulverenti, Timothy S. Blazevich, Anthony J. |
author_facet | Bochkezanian, Vanesa Newton, Robert U. Trajano, Gabriel S. Vieira, Amilton Pulverenti, Timothy S. Blazevich, Anthony J. |
author_sort | Bochkezanian, Vanesa |
collection | PubMed |
description | BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before “muscle fatigue”, and the post-exercise recovery of muscle function. METHODS: Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. RESULTS: TTI increased (145.0 ± 127.7%) in STIM only for “positive responders” to the tendon vibration (8/16 subjects), but decreased in “negative responders” (−43.5 ± 25.7%). MVIC (−8.7%) and rectus femoris electromyography (RF EMG) (−16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. CONCLUSIONS: Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone. |
format | Online Article Text |
id | pubmed-5414318 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54143182017-05-03 Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force Bochkezanian, Vanesa Newton, Robert U. Trajano, Gabriel S. Vieira, Amilton Pulverenti, Timothy S. Blazevich, Anthony J. BMC Neurol Research Article BACKGROUND: Neuromuscular electrical stimulation (NMES) is commonly used to activate skeletal muscles and reverse muscle atrophy in clinical populations. Clinical recommendations for NMES suggest the use of short pulse widths (100–200 μs) and low-to-moderate pulse frequencies (30–50 Hz). However, this type of NMES causes rapid muscle fatigue due to the (non-physiological) high stimulation intensities and non-orderly recruitment of motor units. The use of both wide pulse widths (1000 μs) and tendon vibration might optimize motor unit activation through spinal reflex pathways and thus delay the onset of muscle fatigue, increasing muscle force and mass. Thus, the objective of this study was to examine the acute effects of patellar tendon vibration superimposed onto wide-pulse width (1000 μs) knee extensor electrical stimulation (NMES, 30 Hz) on peak muscle force, total impulse before “muscle fatigue”, and the post-exercise recovery of muscle function. METHODS: Tendon vibration (Vib), NMES (STIM) or NMES superimposed onto vibration (STIM + Vib) were applied in separate sessions to 16 healthy adults. Total torque-time integral (TTI), maximal voluntary contraction torque (MVIC) and indirect measures of muscle damage were tested before, immediately after, 1 h and 48 h after each stimulus. RESULTS: TTI increased (145.0 ± 127.7%) in STIM only for “positive responders” to the tendon vibration (8/16 subjects), but decreased in “negative responders” (−43.5 ± 25.7%). MVIC (−8.7%) and rectus femoris electromyography (RF EMG) (−16.7%) decreased after STIM (group effect) for at least 1 h, but not after STIM + Vib. No changes were detected in indirect markers of muscle damage in any condition. CONCLUSIONS: Tendon vibration superimposed onto wide-pulse width NMES increased TTI only in 8 of 16 subjects, but reduced voluntary force loss (fatigue) ubiquitously. Negative responders to tendon vibration may derive greater benefit from wide-pulse width NMES alone. BioMed Central 2017-05-02 /pmc/articles/PMC5414318/ /pubmed/28464800 http://dx.doi.org/10.1186/s12883-017-0862-x Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Bochkezanian, Vanesa Newton, Robert U. Trajano, Gabriel S. Vieira, Amilton Pulverenti, Timothy S. Blazevich, Anthony J. Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title | Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title_full | Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title_fullStr | Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title_full_unstemmed | Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title_short | Effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (NMES) on the decline and recovery of muscle force |
title_sort | effect of tendon vibration during wide-pulse neuromuscular electrical stimulation (nmes) on the decline and recovery of muscle force |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5414318/ https://www.ncbi.nlm.nih.gov/pubmed/28464800 http://dx.doi.org/10.1186/s12883-017-0862-x |
work_keys_str_mv | AT bochkezanianvanesa effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce AT newtonrobertu effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce AT trajanogabriels effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce AT vieiraamilton effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce AT pulverentitimothys effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce AT blazevichanthonyj effectoftendonvibrationduringwidepulseneuromuscularelectricalstimulationnmesonthedeclineandrecoveryofmuscleforce |