Plate osteosynthesis after patellar fracture: 1-year results of a prospective study

AIMS AND OBJECTIVES: Tension band wiring after patellar fractures is associated to a high number of implant related complications (22-53%). Revision surgery is necessary in 10-55% of the patients with mostly unsatisfactory results. The patella plate is an alternative treatment with the advantages of...