A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)

AIMS AND OBJECTIVES: The use of patient-specific instruments (PSI) in total knee arthroplasty (TKA) has seen growing interest over the past years. A potential disadvantage of PSI is that functional implant alignment is not applicable in this technique. This study therefore aimed to develop a surgica...

Descripción completa

Detalles Bibliográficos
Autor principal: Hommel, Hagen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5415038/
http://dx.doi.org/10.1177/2325967117S00134
_version_ 1783233455659679744
author Hommel, Hagen
author_facet Hommel, Hagen
author_sort Hommel, Hagen
collection PubMed
description AIMS AND OBJECTIVES: The use of patient-specific instruments (PSI) in total knee arthroplasty (TKA) has seen growing interest over the past years. A potential disadvantage of PSI is that functional implant alignment is not applicable in this technique. This study therefore aimed to develop a surgical technique for ligament-balanced implant alignment based on PSI, and to present the results obtained using this technique. MATERIALS AND METHODS: 25 patients were included in this prospective study. PSI was used for the resection of the extension gap. Ligament tension was measured after removal of all accessible osteophytes. In the event of asymmetry, the distal femur resection was adjusted up to 2.5° using an adjustable cutting block. The aim was to achieve a symmetrical extension gap without release, not a neutral leg axis. Femoral rotation was aligned on the basis of ligament tension. Patients were followed up 3 months postoperatively. RESULTS: The postoperative whole-leg axis was 2.8°±1.6° varus. Patients achieved a flexion of 118.9°±9°, a Knee Score of 91.5±3.2 and a Function Score of 86.8±8.3 points. CONCLUSION: For the first time, the new surgical technique described here permits a functional, ligament-balanced implant alignment based on PSI. It was shown to be safe, with encouraging clinical and radiological results.
format Online
Article
Text
id pubmed-5415038
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-54150382017-05-15 A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI) Hommel, Hagen Orthop J Sports Med Article AIMS AND OBJECTIVES: The use of patient-specific instruments (PSI) in total knee arthroplasty (TKA) has seen growing interest over the past years. A potential disadvantage of PSI is that functional implant alignment is not applicable in this technique. This study therefore aimed to develop a surgical technique for ligament-balanced implant alignment based on PSI, and to present the results obtained using this technique. MATERIALS AND METHODS: 25 patients were included in this prospective study. PSI was used for the resection of the extension gap. Ligament tension was measured after removal of all accessible osteophytes. In the event of asymmetry, the distal femur resection was adjusted up to 2.5° using an adjustable cutting block. The aim was to achieve a symmetrical extension gap without release, not a neutral leg axis. Femoral rotation was aligned on the basis of ligament tension. Patients were followed up 3 months postoperatively. RESULTS: The postoperative whole-leg axis was 2.8°±1.6° varus. Patients achieved a flexion of 118.9°±9°, a Knee Score of 91.5±3.2 and a Function Score of 86.8±8.3 points. CONCLUSION: For the first time, the new surgical technique described here permits a functional, ligament-balanced implant alignment based on PSI. It was shown to be safe, with encouraging clinical and radiological results. SAGE Publications 2017-05-01 /pmc/articles/PMC5415038/ http://dx.doi.org/10.1177/2325967117S00134 Text en © The Author(s) 2017 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Hommel, Hagen
A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title_full A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title_fullStr A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title_full_unstemmed A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title_short A new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (PSI)
title_sort new surgical technique for functional implant alignment in varus osteoarthritis using patient-specific instrumentation (psi)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5415038/
http://dx.doi.org/10.1177/2325967117S00134
work_keys_str_mv AT hommelhagen anewsurgicaltechniqueforfunctionalimplantalignmentinvarusosteoarthritisusingpatientspecificinstrumentationpsi
AT hommelhagen newsurgicaltechniqueforfunctionalimplantalignmentinvarusosteoarthritisusingpatientspecificinstrumentationpsi