Cargando…

Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial

BACKGROUND AND AIMS: The Airtraq™ optical laryngoscope is the only marketed videolaryngoscope for paediatric patients besides the fibre-optic bronchoscope. We hypothesized that intubation would be easier with Airtraq™ compared to Miller blade. Hence, we compared Airtraq™ with the Miller laryngoscope...

Descripción completa

Detalles Bibliográficos
Autores principales: Das, Bikramjit, Samanta, Arijit, Mitra, Subhro, Jamil, Shahin Nikhat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5416723/
https://www.ncbi.nlm.nih.gov/pubmed/28515521
http://dx.doi.org/10.4103/ija.IJA_541_15
_version_ 1783233807699148800
author Das, Bikramjit
Samanta, Arijit
Mitra, Subhro
Jamil, Shahin Nikhat
author_facet Das, Bikramjit
Samanta, Arijit
Mitra, Subhro
Jamil, Shahin Nikhat
author_sort Das, Bikramjit
collection PubMed
description BACKGROUND AND AIMS: The Airtraq™ optical laryngoscope is the only marketed videolaryngoscope for paediatric patients besides the fibre-optic bronchoscope. We hypothesized that intubation would be easier with Airtraq™ compared to Miller blade. Hence, we compared Airtraq™ with the Miller laryngoscope as intubation devices in paediatric patients. METHODS: This prospective, randomized study was conducted in a tertiary care teaching hospital. Sixty children belonging to American Society of Anesthesiologists' Grade I–II, aged 2–10 years, posted for routine surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Miller (n = 30) or Airtraq™ (n = 30) laryngoscope. The primary outcome measure was time of intubation. We also measured ease of intubation, number of attempts, percentage of glottic opening score (POGO), haemodynamic changes and airway trauma. Student t test was used to analyse parametric data. RESULTS: Intubation time was comparable between Miller's laryngoscope (15.13 ± 1.33s) compared to Airtraq™ (11.53 ± 0.49 s) (P = 0.29) The number of first and second attempts at intubation were 25 and 5 for the Miller laryngoscope and 29 and 1 for the Airtraq™. Median visual analogue score (VAS) for ease of intubation was 5 in Miller group compared to 3 in Airtraq™ group. The median POGO score was 75 in the Miller group and 100 in the Airtraq™ group (P = 0.01). Haemodynamic changes were maximum and most significant immediately and 1 min after intubation. Airway trauma occurred in three patients (9.09%) in Miller group and one patient (3.33%) in Airtraq™ group. CONCLUSION: The Airtraq™ reduced the difficulty of tracheal intubation and degree of haemodynamic stimulation compared to the Miller laryngoscope in paediatric patients.
format Online
Article
Text
id pubmed-5416723
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54167232017-05-17 Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial Das, Bikramjit Samanta, Arijit Mitra, Subhro Jamil, Shahin Nikhat Indian J Anaesth Original Article BACKGROUND AND AIMS: The Airtraq™ optical laryngoscope is the only marketed videolaryngoscope for paediatric patients besides the fibre-optic bronchoscope. We hypothesized that intubation would be easier with Airtraq™ compared to Miller blade. Hence, we compared Airtraq™ with the Miller laryngoscope as intubation devices in paediatric patients. METHODS: This prospective, randomized study was conducted in a tertiary care teaching hospital. Sixty children belonging to American Society of Anesthesiologists' Grade I–II, aged 2–10 years, posted for routine surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Miller (n = 30) or Airtraq™ (n = 30) laryngoscope. The primary outcome measure was time of intubation. We also measured ease of intubation, number of attempts, percentage of glottic opening score (POGO), haemodynamic changes and airway trauma. Student t test was used to analyse parametric data. RESULTS: Intubation time was comparable between Miller's laryngoscope (15.13 ± 1.33s) compared to Airtraq™ (11.53 ± 0.49 s) (P = 0.29) The number of first and second attempts at intubation were 25 and 5 for the Miller laryngoscope and 29 and 1 for the Airtraq™. Median visual analogue score (VAS) for ease of intubation was 5 in Miller group compared to 3 in Airtraq™ group. The median POGO score was 75 in the Miller group and 100 in the Airtraq™ group (P = 0.01). Haemodynamic changes were maximum and most significant immediately and 1 min after intubation. Airway trauma occurred in three patients (9.09%) in Miller group and one patient (3.33%) in Airtraq™ group. CONCLUSION: The Airtraq™ reduced the difficulty of tracheal intubation and degree of haemodynamic stimulation compared to the Miller laryngoscope in paediatric patients. Medknow Publications & Media Pvt Ltd 2017-04 /pmc/articles/PMC5416723/ /pubmed/28515521 http://dx.doi.org/10.4103/ija.IJA_541_15 Text en Copyright: © 2017 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Das, Bikramjit
Samanta, Arijit
Mitra, Subhro
Jamil, Shahin Nikhat
Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title_full Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title_fullStr Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title_full_unstemmed Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title_short Comparative evaluation of Airtraq™ optical Laryngoscope and Miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: A randomized, controlled trial
title_sort comparative evaluation of airtraq™ optical laryngoscope and miller's blade in paediatric patients undergoing elective surgery requiring tracheal intubation: a randomized, controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5416723/
https://www.ncbi.nlm.nih.gov/pubmed/28515521
http://dx.doi.org/10.4103/ija.IJA_541_15
work_keys_str_mv AT dasbikramjit comparativeevaluationofairtraqopticallaryngoscopeandmillersbladeinpaediatricpatientsundergoingelectivesurgeryrequiringtrachealintubationarandomizedcontrolledtrial
AT samantaarijit comparativeevaluationofairtraqopticallaryngoscopeandmillersbladeinpaediatricpatientsundergoingelectivesurgeryrequiringtrachealintubationarandomizedcontrolledtrial
AT mitrasubhro comparativeevaluationofairtraqopticallaryngoscopeandmillersbladeinpaediatricpatientsundergoingelectivesurgeryrequiringtrachealintubationarandomizedcontrolledtrial
AT jamilshahinnikhat comparativeevaluationofairtraqopticallaryngoscopeandmillersbladeinpaediatricpatientsundergoingelectivesurgeryrequiringtrachealintubationarandomizedcontrolledtrial