Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy

Development and comparison of spine-shaped phantoms generated by two different 3D-printing technologies, digital light processing (DLP) and Polyjet has been purposed to utilize in patient-specific quality assurance (QA) of stereotactic body radiation treatment. The developed 3D-printed spine QA phan...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Min-Joo, Lee, Seu-Ran, Lee, Min-Young, Sohn, Jason W., Yun, Hyong Geon, Choi, Joon Yong, Jeon, Sang Won, Suh, Tae Suk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5417437/
https://www.ncbi.nlm.nih.gov/pubmed/28472175
http://dx.doi.org/10.1371/journal.pone.0176227
_version_ 1783233890694987776
author Kim, Min-Joo
Lee, Seu-Ran
Lee, Min-Young
Sohn, Jason W.
Yun, Hyong Geon
Choi, Joon Yong
Jeon, Sang Won
Suh, Tae Suk
author_facet Kim, Min-Joo
Lee, Seu-Ran
Lee, Min-Young
Sohn, Jason W.
Yun, Hyong Geon
Choi, Joon Yong
Jeon, Sang Won
Suh, Tae Suk
author_sort Kim, Min-Joo
collection PubMed
description Development and comparison of spine-shaped phantoms generated by two different 3D-printing technologies, digital light processing (DLP) and Polyjet has been purposed to utilize in patient-specific quality assurance (QA) of stereotactic body radiation treatment. The developed 3D-printed spine QA phantom consisted of an acrylic body phantom and a 3D-printed spine shaped object. DLP and Polyjet 3D printers using a high-density acrylic polymer were employed to produce spine-shaped phantoms based on CT images. Image fusion was performed to evaluate the reproducibility of our phantom, and the Hounsfield units (HUs) were measured based on each CT image. Two different intensity-modulated radiotherapy plans based on both CT phantom image sets from the two printed spine-shaped phantoms with acrylic body phantoms were designed to deliver 16 Gy dose to the planning target volume (PTV) and were compared for target coverage and normal organ-sparing. Image fusion demonstrated good reproducibility of the developed phantom. The HU values of the DLP- and Polyjet-printed spine vertebrae differed by 54.3 on average. The PTV D(max) dose for the DLP-generated phantom was about 1.488 Gy higher than that for the Polyjet-generated phantom. The organs at risk received a lower dose for the 3D printed spine-shaped phantom image using the DLP technique than for the phantom image using the Polyjet technique. Despite using the same material for printing the spine-shaped phantom, these phantoms generated by different 3D printing techniques, DLP and Polyjet, showed different HU values and these differently appearing HU values according to the printing technique could be an extra consideration for developing the 3D printed spine-shaped phantom depending on the patient’s age and the density of the spinal bone. Therefore, the 3D printing technique and materials should be carefully chosen by taking into account the condition of the patient in order to accurately produce 3D printed patient-specific QA phantom.
format Online
Article
Text
id pubmed-5417437
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54174372017-05-14 Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy Kim, Min-Joo Lee, Seu-Ran Lee, Min-Young Sohn, Jason W. Yun, Hyong Geon Choi, Joon Yong Jeon, Sang Won Suh, Tae Suk PLoS One Research Article Development and comparison of spine-shaped phantoms generated by two different 3D-printing technologies, digital light processing (DLP) and Polyjet has been purposed to utilize in patient-specific quality assurance (QA) of stereotactic body radiation treatment. The developed 3D-printed spine QA phantom consisted of an acrylic body phantom and a 3D-printed spine shaped object. DLP and Polyjet 3D printers using a high-density acrylic polymer were employed to produce spine-shaped phantoms based on CT images. Image fusion was performed to evaluate the reproducibility of our phantom, and the Hounsfield units (HUs) were measured based on each CT image. Two different intensity-modulated radiotherapy plans based on both CT phantom image sets from the two printed spine-shaped phantoms with acrylic body phantoms were designed to deliver 16 Gy dose to the planning target volume (PTV) and were compared for target coverage and normal organ-sparing. Image fusion demonstrated good reproducibility of the developed phantom. The HU values of the DLP- and Polyjet-printed spine vertebrae differed by 54.3 on average. The PTV D(max) dose for the DLP-generated phantom was about 1.488 Gy higher than that for the Polyjet-generated phantom. The organs at risk received a lower dose for the 3D printed spine-shaped phantom image using the DLP technique than for the phantom image using the Polyjet technique. Despite using the same material for printing the spine-shaped phantom, these phantoms generated by different 3D printing techniques, DLP and Polyjet, showed different HU values and these differently appearing HU values according to the printing technique could be an extra consideration for developing the 3D printed spine-shaped phantom depending on the patient’s age and the density of the spinal bone. Therefore, the 3D printing technique and materials should be carefully chosen by taking into account the condition of the patient in order to accurately produce 3D printed patient-specific QA phantom. Public Library of Science 2017-05-04 /pmc/articles/PMC5417437/ /pubmed/28472175 http://dx.doi.org/10.1371/journal.pone.0176227 Text en © 2017 Kim et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Kim, Min-Joo
Lee, Seu-Ran
Lee, Min-Young
Sohn, Jason W.
Yun, Hyong Geon
Choi, Joon Yong
Jeon, Sang Won
Suh, Tae Suk
Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title_full Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title_fullStr Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title_full_unstemmed Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title_short Characterization of 3D printing techniques: Toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
title_sort characterization of 3d printing techniques: toward patient specific quality assurance spine-shaped phantom for stereotactic body radiation therapy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5417437/
https://www.ncbi.nlm.nih.gov/pubmed/28472175
http://dx.doi.org/10.1371/journal.pone.0176227
work_keys_str_mv AT kimminjoo characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT leeseuran characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT leeminyoung characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT sohnjasonw characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT yunhyonggeon characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT choijoonyong characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT jeonsangwon characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy
AT suhtaesuk characterizationof3dprintingtechniquestowardpatientspecificqualityassurancespineshapedphantomforstereotacticbodyradiationtherapy