Cargando…
Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method
BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality worldwide. A combination of indacaterol maleate with glycopyrronium bromide has recently been approved as a once-daily maintenance therapy in patients with COPD. The very low dose (μg level/capsule)...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5418180/ https://www.ncbi.nlm.nih.gov/pubmed/29086816 http://dx.doi.org/10.1186/s13065-017-0264-6 |
_version_ | 1783234019486334976 |
---|---|
author | Zayed, Sahar Belal, Fathalla |
author_facet | Zayed, Sahar Belal, Fathalla |
author_sort | Zayed, Sahar |
collection | PubMed |
description | BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality worldwide. A combination of indacaterol maleate with glycopyrronium bromide has recently been approved as a once-daily maintenance therapy in patients with COPD. The very low dose (μg level/capsule) renders the analysis of such products challenges. This study reports for the first time about HPLC method for the quality control of such combination and it is a stability indicating at the same time. RESULTS: A rapid, simple, precise and reproducible HPLC method was developed and validated for simultaneous determination of indacaterol maleate and glycopyrronium bromide using tenoxicam as an internal standard. The chromatographic separation was achieved on an onyx monolithic C18 column (100 × 4.6 mm) using a mobile phase consisting of acetonitrile and 30 mM phosphate buffer (pH 3.5) (30:70, v/v), run at a flow rate of 2 mL/min with UV detection at 210 nm. The total analysis time was less than 3 min. The HPLC method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 1–44 µg/mL for indacaterol maleate and 0.5–20 µg/mL for glycopyrronium bromide. Stability tests were done through exposure of the analyte solution for different stress conditions and the results indicate no interference of degradants with HPLC method. CONCLUSIONS: The method was successfully applied for the quantitative analysis of indacaterol maleate and glycopyrronium bromide both individually and in a combined pharmaceutical inhaler capsules to support the quality control and to assure the therapeutic efficacy of the two drugs. The simple procedure involved in sample preparation and the short run-time added the important property of high throughput to the method. [Figure: see text] |
format | Online Article Text |
id | pubmed-5418180 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-54181802017-05-19 Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method Zayed, Sahar Belal, Fathalla Chem Cent J Research Article BACKGROUND: Chronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality worldwide. A combination of indacaterol maleate with glycopyrronium bromide has recently been approved as a once-daily maintenance therapy in patients with COPD. The very low dose (μg level/capsule) renders the analysis of such products challenges. This study reports for the first time about HPLC method for the quality control of such combination and it is a stability indicating at the same time. RESULTS: A rapid, simple, precise and reproducible HPLC method was developed and validated for simultaneous determination of indacaterol maleate and glycopyrronium bromide using tenoxicam as an internal standard. The chromatographic separation was achieved on an onyx monolithic C18 column (100 × 4.6 mm) using a mobile phase consisting of acetonitrile and 30 mM phosphate buffer (pH 3.5) (30:70, v/v), run at a flow rate of 2 mL/min with UV detection at 210 nm. The total analysis time was less than 3 min. The HPLC method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 1–44 µg/mL for indacaterol maleate and 0.5–20 µg/mL for glycopyrronium bromide. Stability tests were done through exposure of the analyte solution for different stress conditions and the results indicate no interference of degradants with HPLC method. CONCLUSIONS: The method was successfully applied for the quantitative analysis of indacaterol maleate and glycopyrronium bromide both individually and in a combined pharmaceutical inhaler capsules to support the quality control and to assure the therapeutic efficacy of the two drugs. The simple procedure involved in sample preparation and the short run-time added the important property of high throughput to the method. [Figure: see text] Springer International Publishing 2017-05-04 /pmc/articles/PMC5418180/ /pubmed/29086816 http://dx.doi.org/10.1186/s13065-017-0264-6 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Zayed, Sahar Belal, Fathalla Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title | Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title_full | Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title_fullStr | Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title_full_unstemmed | Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title_short | Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method |
title_sort | rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic lc method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5418180/ https://www.ncbi.nlm.nih.gov/pubmed/29086816 http://dx.doi.org/10.1186/s13065-017-0264-6 |
work_keys_str_mv | AT zayedsahar rapidsimultaneousdeterminationofindacaterolmaleateandglycopyrroniumbromideininhalercapsulesusingavalidatedstabilityindicatingmonolithiclcmethod AT belalfathalla rapidsimultaneousdeterminationofindacaterolmaleateandglycopyrroniumbromideininhalercapsulesusingavalidatedstabilityindicatingmonolithiclcmethod |