Cargando…

Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising

BACKGROUND: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of ind...

Descripción completa

Detalles Bibliográficos
Autores principales: Agostinelli, Angela, Sbrollini, Agnese, Burattini, Luca, Fioretti, Sandro, Di Nardo, Francesco, Burattini, Laura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5418918/
https://www.ncbi.nlm.nih.gov/pubmed/28567129
http://dx.doi.org/10.2174/1874120701711010025
Descripción
Sumario:BACKGROUND: Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. OBJECTIVE: Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. METHOD: Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. RESULTS: Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10(-4)), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10(-2)) and significantly in indirect recording (P=1.90·10(-3)). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10(-3)), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10(-4)). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10(-208)), indicating that the two electrocardiograms were morphologically equivalent. CONCLUSION: Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice.