Low concentration DNA extraction and recovery using a silica solid phase

DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input...

Descripción completa

Detalles Bibliográficos
Autores principales: Katevatis, Constantinos, Fan, Andy, Klapperich, Catherine M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5419563/
https://www.ncbi.nlm.nih.gov/pubmed/28475611
http://dx.doi.org/10.1371/journal.pone.0176848
_version_ 1783234237690806272
author Katevatis, Constantinos
Fan, Andy
Klapperich, Catherine M.
author_facet Katevatis, Constantinos
Fan, Andy
Klapperich, Catherine M.
author_sort Katevatis, Constantinos
collection PubMed
description DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input DNA. Thus, when the input clinical sample contains less than 1 μg of total DNA, the target-specific DNA recovery from most of these protocols is low without supplementing the sample with exogenous carrier DNA. In fact, many clinical samples used in the development of POC diagnostics often exhibit target DNA concentrations as low as 3 ng/mL. With the broader goal of improving the yield and efficiency of nucleic acid-based POC devices for dilute samples, we investigated both DNA adsorption and recovery from silica particles by using 1 pg– 1 μg of DNA with a set of adsorption and elution buffers ranging in pH and chaotropic presence. In terms of adsorption, we found that low pH and the presence of chaotropic guanidinium thiocyanate (GuSCN) enhanced DNA-silica adsorption. When eluting with a standard low-salt, high-pH buffer, > 70% of DNA was unrecoverable, except when DNA was initially adsorbed with 5 M GuSCN at pH 5.2. Unrecovered DNA was either not initially adsorbed or irreversibly bound on the silica surface. Recovery was improved when eluting with 95°C formamide and 1 M NaOH, which suggested that DNA-silica-chaotrope interactions are dominated by hydrophobic interactions and hydrogen bonding. While heated formamide and NaOH are non-ideal elution buffers for practical POC devices, the salient results are important for engineering a set of optimized reagents that could maximize nucleic acid recovery from a microfluidic DNA-silica-chaotrope system.
format Online
Article
Text
id pubmed-5419563
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54195632017-05-14 Low concentration DNA extraction and recovery using a silica solid phase Katevatis, Constantinos Fan, Andy Klapperich, Catherine M. PLoS One Research Article DNA extraction from clinical samples is commonly achieved with a silica solid phase extraction column in the presence of a chaotrope. Versions of these protocols have been adapted for point of care (POC) diagnostic devices in miniaturized platforms, but commercial kits require a high amount of input DNA. Thus, when the input clinical sample contains less than 1 μg of total DNA, the target-specific DNA recovery from most of these protocols is low without supplementing the sample with exogenous carrier DNA. In fact, many clinical samples used in the development of POC diagnostics often exhibit target DNA concentrations as low as 3 ng/mL. With the broader goal of improving the yield and efficiency of nucleic acid-based POC devices for dilute samples, we investigated both DNA adsorption and recovery from silica particles by using 1 pg– 1 μg of DNA with a set of adsorption and elution buffers ranging in pH and chaotropic presence. In terms of adsorption, we found that low pH and the presence of chaotropic guanidinium thiocyanate (GuSCN) enhanced DNA-silica adsorption. When eluting with a standard low-salt, high-pH buffer, > 70% of DNA was unrecoverable, except when DNA was initially adsorbed with 5 M GuSCN at pH 5.2. Unrecovered DNA was either not initially adsorbed or irreversibly bound on the silica surface. Recovery was improved when eluting with 95°C formamide and 1 M NaOH, which suggested that DNA-silica-chaotrope interactions are dominated by hydrophobic interactions and hydrogen bonding. While heated formamide and NaOH are non-ideal elution buffers for practical POC devices, the salient results are important for engineering a set of optimized reagents that could maximize nucleic acid recovery from a microfluidic DNA-silica-chaotrope system. Public Library of Science 2017-05-05 /pmc/articles/PMC5419563/ /pubmed/28475611 http://dx.doi.org/10.1371/journal.pone.0176848 Text en © 2017 Katevatis et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Katevatis, Constantinos
Fan, Andy
Klapperich, Catherine M.
Low concentration DNA extraction and recovery using a silica solid phase
title Low concentration DNA extraction and recovery using a silica solid phase
title_full Low concentration DNA extraction and recovery using a silica solid phase
title_fullStr Low concentration DNA extraction and recovery using a silica solid phase
title_full_unstemmed Low concentration DNA extraction and recovery using a silica solid phase
title_short Low concentration DNA extraction and recovery using a silica solid phase
title_sort low concentration dna extraction and recovery using a silica solid phase
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5419563/
https://www.ncbi.nlm.nih.gov/pubmed/28475611
http://dx.doi.org/10.1371/journal.pone.0176848
work_keys_str_mv AT katevatisconstantinos lowconcentrationdnaextractionandrecoveryusingasilicasolidphase
AT fanandy lowconcentrationdnaextractionandrecoveryusingasilicasolidphase
AT klapperichcatherinem lowconcentrationdnaextractionandrecoveryusingasilicasolidphase