Cargando…

A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement

BACKGROUND: Coronal shear fracture type IV of the distal part of humerus is a very rare injury with articular complexity potentially leading to posttraumatic osteoarthritis. One option for surgical treatment of advanced unicompartmental radiocapitellar osteoarthritis is resurfacing radiocapitellar j...

Descripción completa

Detalles Bibliográficos
Autor principal: Schmidt, Ingo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5420185/
https://www.ncbi.nlm.nih.gov/pubmed/28567152
http://dx.doi.org/10.2174/1874325001711010248
_version_ 1783234365938991104
author Schmidt, Ingo
author_facet Schmidt, Ingo
author_sort Schmidt, Ingo
collection PubMed
description BACKGROUND: Coronal shear fracture type IV of the distal part of humerus is a very rare injury with articular complexity potentially leading to posttraumatic osteoarthritis. One option for surgical treatment of advanced unicompartmental radiocapitellar osteoarthritis is resurfacing radiocapitellar joint replacement. METHOD: A 62-year- old female sustained a coronal shear fracture type IV of the distal part of left humerus that was primarily treated with open reduction and internal fixation using headless compression screws. Three years postoperatively, there was a migration of one screw into radiocapitellar joint that led to circular deep cartilage defect of radial head. Four years after ORIF, a distinctive radiocapitellar osteoarthritis has evolved leading to a resurfacing radiocapitellar joint replacement using the Lateral Resurfacing Elbow(TM) (LRE) system. RESULT: At the 2-year follow-up after that procedure, there was an excellent subjective and functional outcome. Radiographically, no loosening or subsidence of implant without any signs of overstuffing could be found. The patient reported that she would have the same procedure again. CONCLUSION: The goal of unicompartmental radiocapitellar replacement is to obtain stability in elbow joint by avoiding cubitus valgus with subsequent instability of the distal radioulnar joint, and it does not alter the unaffected ulnohumeral joint. Additionally, the feature of the LRE(TM) system is that the radial head is not excised, and so will receive the anatomical length of the overall radius articulating with the capitellum by preserving the annular ligament. In the literature only three publications could be found in which short-term results with the use of the LRE(TM) system have been described. Hence, further studies are needed to validate this concept.
format Online
Article
Text
id pubmed-5420185
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-54201852017-05-31 A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement Schmidt, Ingo Open Orthop J Article BACKGROUND: Coronal shear fracture type IV of the distal part of humerus is a very rare injury with articular complexity potentially leading to posttraumatic osteoarthritis. One option for surgical treatment of advanced unicompartmental radiocapitellar osteoarthritis is resurfacing radiocapitellar joint replacement. METHOD: A 62-year- old female sustained a coronal shear fracture type IV of the distal part of left humerus that was primarily treated with open reduction and internal fixation using headless compression screws. Three years postoperatively, there was a migration of one screw into radiocapitellar joint that led to circular deep cartilage defect of radial head. Four years after ORIF, a distinctive radiocapitellar osteoarthritis has evolved leading to a resurfacing radiocapitellar joint replacement using the Lateral Resurfacing Elbow(TM) (LRE) system. RESULT: At the 2-year follow-up after that procedure, there was an excellent subjective and functional outcome. Radiographically, no loosening or subsidence of implant without any signs of overstuffing could be found. The patient reported that she would have the same procedure again. CONCLUSION: The goal of unicompartmental radiocapitellar replacement is to obtain stability in elbow joint by avoiding cubitus valgus with subsequent instability of the distal radioulnar joint, and it does not alter the unaffected ulnohumeral joint. Additionally, the feature of the LRE(TM) system is that the radial head is not excised, and so will receive the anatomical length of the overall radius articulating with the capitellum by preserving the annular ligament. In the literature only three publications could be found in which short-term results with the use of the LRE(TM) system have been described. Hence, further studies are needed to validate this concept. Bentham Open 2017-03-31 /pmc/articles/PMC5420185/ /pubmed/28567152 http://dx.doi.org/10.2174/1874325001711010248 Text en © 2017 Ingo Schmidt. https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Article
Schmidt, Ingo
A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title_full A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title_fullStr A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title_full_unstemmed A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title_short A Complicated Course of a Coronal Shear Fracture Type IV of the Distal Part of Humerus Resulting in Resurfacing Radiocapitellar Joint Replacement
title_sort complicated course of a coronal shear fracture type iv of the distal part of humerus resulting in resurfacing radiocapitellar joint replacement
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5420185/
https://www.ncbi.nlm.nih.gov/pubmed/28567152
http://dx.doi.org/10.2174/1874325001711010248
work_keys_str_mv AT schmidtingo acomplicatedcourseofacoronalshearfracturetypeivofthedistalpartofhumerusresultinginresurfacingradiocapitellarjointreplacement
AT schmidtingo complicatedcourseofacoronalshearfracturetypeivofthedistalpartofhumerusresultinginresurfacingradiocapitellarjointreplacement