Cargando…

Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation

During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs) have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fibe...

Descripción completa

Detalles Bibliográficos
Autores principales: Massaroni, Carlo, Caponero, Michele A., D’Amato, Rosaria, Lo Presti, Daniela, Schena, Emiliano
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5421709/
https://www.ncbi.nlm.nih.gov/pubmed/28368339
http://dx.doi.org/10.3390/s17040749
_version_ 1783234628900880384
author Massaroni, Carlo
Caponero, Michele A.
D’Amato, Rosaria
Lo Presti, Daniela
Schena, Emiliano
author_facet Massaroni, Carlo
Caponero, Michele A.
D’Amato, Rosaria
Lo Presti, Daniela
Schena, Emiliano
author_sort Massaroni, Carlo
collection PubMed
description During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs) have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fiber Bragg grating (FBG) for the simultaneous monitoring of gas relative humidity (RH) and temperature, intended to be used for providing feedback to the HWHs’ control. This solution can be implemented using an array of two FBGs having a different center wavelength. Regarding RH monitoring, three sensors have been fabricated by coating an FBG with two different moisture-sensitive and biocompatible materials: the first two sensors were fabricated by coating the grating with a 3 mm × 3 mm layer of agar and agarose; to investigate the influence of the coating thickness to the sensor response, a third sensor was developed with a 5 mm × 5 mm layer of agar. The sensors have been assessed in a wide range of RH (up to 95%) during both an ascending and a subsequent descending phase. Only the response of the 3 mm × 3 mm-coated sensors were fast enough to follow the RH changes, showing a mean sensitivity of about 0.14 nm/% (agar-coated) and 0.12 nm/% (agarose-coated). The hysteresis error was about <10% in the two sensors. The contribution of temperature changes on these RH sensors was negligible. The temperature measurement was performed by a commercial FBG insensitive to RH changes. The small size of these FBG-based sensors, the use of biocompatible polymers, and the possibility to measure both temperature and RH by using the same fiber optic embedding an array of two FBGs make intriguing the use of this solution for application in the control of HWHs.
format Online
Article
Text
id pubmed-5421709
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54217092017-05-12 Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation Massaroni, Carlo Caponero, Michele A. D’Amato, Rosaria Lo Presti, Daniela Schena, Emiliano Sensors (Basel) Article During mechanical ventilation, the humidification of the dry air delivered by the mechanical ventilator is recommended. Among several solutions, heated wire humidifiers (HWHs) have gained large acceptance to be used in this field. The aim of this work is to fabricate a measuring system based on fiber Bragg grating (FBG) for the simultaneous monitoring of gas relative humidity (RH) and temperature, intended to be used for providing feedback to the HWHs’ control. This solution can be implemented using an array of two FBGs having a different center wavelength. Regarding RH monitoring, three sensors have been fabricated by coating an FBG with two different moisture-sensitive and biocompatible materials: the first two sensors were fabricated by coating the grating with a 3 mm × 3 mm layer of agar and agarose; to investigate the influence of the coating thickness to the sensor response, a third sensor was developed with a 5 mm × 5 mm layer of agar. The sensors have been assessed in a wide range of RH (up to 95%) during both an ascending and a subsequent descending phase. Only the response of the 3 mm × 3 mm-coated sensors were fast enough to follow the RH changes, showing a mean sensitivity of about 0.14 nm/% (agar-coated) and 0.12 nm/% (agarose-coated). The hysteresis error was about <10% in the two sensors. The contribution of temperature changes on these RH sensors was negligible. The temperature measurement was performed by a commercial FBG insensitive to RH changes. The small size of these FBG-based sensors, the use of biocompatible polymers, and the possibility to measure both temperature and RH by using the same fiber optic embedding an array of two FBGs make intriguing the use of this solution for application in the control of HWHs. MDPI 2017-04-02 /pmc/articles/PMC5421709/ /pubmed/28368339 http://dx.doi.org/10.3390/s17040749 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Massaroni, Carlo
Caponero, Michele A.
D’Amato, Rosaria
Lo Presti, Daniela
Schena, Emiliano
Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title_full Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title_fullStr Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title_full_unstemmed Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title_short Fiber Bragg Grating Measuring System for Simultaneous Monitoring of Temperature and Humidity in Mechanical Ventilation
title_sort fiber bragg grating measuring system for simultaneous monitoring of temperature and humidity in mechanical ventilation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5421709/
https://www.ncbi.nlm.nih.gov/pubmed/28368339
http://dx.doi.org/10.3390/s17040749
work_keys_str_mv AT massaronicarlo fiberbragggratingmeasuringsystemforsimultaneousmonitoringoftemperatureandhumidityinmechanicalventilation
AT caponeromichelea fiberbragggratingmeasuringsystemforsimultaneousmonitoringoftemperatureandhumidityinmechanicalventilation
AT damatorosaria fiberbragggratingmeasuringsystemforsimultaneousmonitoringoftemperatureandhumidityinmechanicalventilation
AT loprestidaniela fiberbragggratingmeasuringsystemforsimultaneousmonitoringoftemperatureandhumidityinmechanicalventilation
AT schenaemiliano fiberbragggratingmeasuringsystemforsimultaneousmonitoringoftemperatureandhumidityinmechanicalventilation