A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems

This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor inter...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Kyeonghwan, Kim, Seung Mok, Eom, Won-Jin, Kim, Jae Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5421719/
https://www.ncbi.nlm.nih.gov/pubmed/28368355
http://dx.doi.org/10.3390/s17040759
_version_ 1783234631413268480
author Park, Kyeonghwan
Kim, Seung Mok
Eom, Won-Jin
Kim, Jae Joon
author_facet Park, Kyeonghwan
Kim, Seung Mok
Eom, Won-Jin
Kim, Jae Joon
author_sort Park, Kyeonghwan
collection PubMed
description This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR) of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 μm complementary metal oxide semiconductor (CMOS) process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors.
format Online
Article
Text
id pubmed-5421719
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54217192017-05-12 A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems Park, Kyeonghwan Kim, Seung Mok Eom, Won-Jin Kim, Jae Joon Sensors (Basel) Article This paper presents a reconfigurable multi-sensor interface and its readout integrated circuit (ROIC) for display-based multi-sensor systems, which builds up multi-sensor functions by utilizing touch screen panels. In addition to inherent touch detection, physiological and environmental sensor interfaces are incorporated. The reconfigurable feature is effectively implemented by proposing two basis readout topologies of amplifier-based and oscillator-based circuits. For noise-immune design against various noises from inherent human-touch operations, an alternate-sampling error-correction scheme is proposed and integrated inside the ROIC, achieving a 12-bit resolution of successive approximation register (SAR) of analog-to-digital conversion without additional calibrations. A ROIC prototype that includes the whole proposed functions and data converters was fabricated in a 0.18 μm complementary metal oxide semiconductor (CMOS) process, and its feasibility was experimentally verified to support multiple heterogeneous sensing functions of touch, electrocardiogram, body impedance, and environmental sensors. MDPI 2017-04-03 /pmc/articles/PMC5421719/ /pubmed/28368355 http://dx.doi.org/10.3390/s17040759 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Park, Kyeonghwan
Kim, Seung Mok
Eom, Won-Jin
Kim, Jae Joon
A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title_full A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title_fullStr A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title_full_unstemmed A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title_short A Reconfigurable Readout Integrated Circuit for Heterogeneous Display-Based Multi-Sensor Systems
title_sort reconfigurable readout integrated circuit for heterogeneous display-based multi-sensor systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5421719/
https://www.ncbi.nlm.nih.gov/pubmed/28368355
http://dx.doi.org/10.3390/s17040759
work_keys_str_mv AT parkkyeonghwan areconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT kimseungmok areconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT eomwonjin areconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT kimjaejoon areconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT parkkyeonghwan reconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT kimseungmok reconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT eomwonjin reconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems
AT kimjaejoon reconfigurablereadoutintegratedcircuitforheterogeneousdisplaybasedmultisensorsystems