Cargando…

A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems

Due to the non-line-of-sight (NLOS) and multipath fading channel (MPF) of the wireless networks, the non-existence of the intersection point often occurs in the range-based localization methods, e.g., the centroid-based trilateration method. To alleviate the problem, a confidence-based intersection...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Jiahong, Yue, Xianghu, Chen, Jie, Deng, Fang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422068/
https://www.ncbi.nlm.nih.gov/pubmed/28387731
http://dx.doi.org/10.3390/s17040795
_version_ 1783234712515379200
author Li, Jiahong
Yue, Xianghu
Chen, Jie
Deng, Fang
author_facet Li, Jiahong
Yue, Xianghu
Chen, Jie
Deng, Fang
author_sort Li, Jiahong
collection PubMed
description Due to the non-line-of-sight (NLOS) and multipath fading channel (MPF) of the wireless networks, the non-existence of the intersection point often occurs in the range-based localization methods, e.g., the centroid-based trilateration method. To alleviate the problem, a confidence-based intersection method which expands the range of the circle within a certain confidence interval is proposed. In the method, the confidence interval is estimated based on the Cramér–Rao lower bound of the time of flight (TOF) measurement. Furthermore, an intersection determination method is proposed to select the intersection point with higher confidence level. The simulation and experimental results show the superiority of the proposed method in localization accuracy and robustness to noise compared to the conventional trilateration method, e.g., the centroid-based and least squares based trilateration methods.
format Online
Article
Text
id pubmed-5422068
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54220682017-05-12 A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems Li, Jiahong Yue, Xianghu Chen, Jie Deng, Fang Sensors (Basel) Article Due to the non-line-of-sight (NLOS) and multipath fading channel (MPF) of the wireless networks, the non-existence of the intersection point often occurs in the range-based localization methods, e.g., the centroid-based trilateration method. To alleviate the problem, a confidence-based intersection method which expands the range of the circle within a certain confidence interval is proposed. In the method, the confidence interval is estimated based on the Cramér–Rao lower bound of the time of flight (TOF) measurement. Furthermore, an intersection determination method is proposed to select the intersection point with higher confidence level. The simulation and experimental results show the superiority of the proposed method in localization accuracy and robustness to noise compared to the conventional trilateration method, e.g., the centroid-based and least squares based trilateration methods. MDPI 2017-04-07 /pmc/articles/PMC5422068/ /pubmed/28387731 http://dx.doi.org/10.3390/s17040795 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Jiahong
Yue, Xianghu
Chen, Jie
Deng, Fang
A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title_full A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title_fullStr A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title_full_unstemmed A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title_short A Novel Robust Trilateration Method Applied to Ultra-Wide Bandwidth Location Systems
title_sort novel robust trilateration method applied to ultra-wide bandwidth location systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422068/
https://www.ncbi.nlm.nih.gov/pubmed/28387731
http://dx.doi.org/10.3390/s17040795
work_keys_str_mv AT lijiahong anovelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT yuexianghu anovelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT chenjie anovelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT dengfang anovelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT lijiahong novelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT yuexianghu novelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT chenjie novelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems
AT dengfang novelrobusttrilaterationmethodappliedtoultrawidebandwidthlocationsystems