Cargando…

Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation

To improve the phase-shifting accuracy, this paper presents a novel integrated framework for design, control and experimental validation of the piezoelectric actuated phase shifter with a trade-off between accuracy and cost. The piezoelectric actuators with built-in sensors are adopted to drive the...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Peng-Zhi, Wang, Xiao-Dong, Sui, Yong-Xin, Zhang, De-Fu, Wang, Dong-Fang, Dong, Li-Jian, Ni, Ming-Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422199/
https://www.ncbi.nlm.nih.gov/pubmed/28398244
http://dx.doi.org/10.3390/s17040838
_version_ 1783234725852217344
author Li, Peng-Zhi
Wang, Xiao-Dong
Sui, Yong-Xin
Zhang, De-Fu
Wang, Dong-Fang
Dong, Li-Jian
Ni, Ming-Yang
author_facet Li, Peng-Zhi
Wang, Xiao-Dong
Sui, Yong-Xin
Zhang, De-Fu
Wang, Dong-Fang
Dong, Li-Jian
Ni, Ming-Yang
author_sort Li, Peng-Zhi
collection PubMed
description To improve the phase-shifting accuracy, this paper presents a novel integrated framework for design, control and experimental validation of the piezoelectric actuated phase shifter with a trade-off between accuracy and cost. The piezoelectric actuators with built-in sensors are adopted to drive the double parallel four-bar linkage flexure hinge-based mechanisms. Three mechanisms form the tripod structure of the assembled phase shifter. Then, a semi-closed loop controller with inner feedback and outer feedforward loops via the external laser interferometer is developed for accurate positioning of the phase shifter. Finally, experiments related with travel range, step response, linearity and repeatability are carried out. The linearity error is 0.21% and the repeatability error of 10 [Formula: see text] m displacement is 3 nm. The results clearly demonstrate the good performance of the developed phase shifter and the feasibility of the proposed integrated framework.
format Online
Article
Text
id pubmed-5422199
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54221992017-05-12 Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation Li, Peng-Zhi Wang, Xiao-Dong Sui, Yong-Xin Zhang, De-Fu Wang, Dong-Fang Dong, Li-Jian Ni, Ming-Yang Sensors (Basel) Article To improve the phase-shifting accuracy, this paper presents a novel integrated framework for design, control and experimental validation of the piezoelectric actuated phase shifter with a trade-off between accuracy and cost. The piezoelectric actuators with built-in sensors are adopted to drive the double parallel four-bar linkage flexure hinge-based mechanisms. Three mechanisms form the tripod structure of the assembled phase shifter. Then, a semi-closed loop controller with inner feedback and outer feedforward loops via the external laser interferometer is developed for accurate positioning of the phase shifter. Finally, experiments related with travel range, step response, linearity and repeatability are carried out. The linearity error is 0.21% and the repeatability error of 10 [Formula: see text] m displacement is 3 nm. The results clearly demonstrate the good performance of the developed phase shifter and the feasibility of the proposed integrated framework. MDPI 2017-04-11 /pmc/articles/PMC5422199/ /pubmed/28398244 http://dx.doi.org/10.3390/s17040838 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Peng-Zhi
Wang, Xiao-Dong
Sui, Yong-Xin
Zhang, De-Fu
Wang, Dong-Fang
Dong, Li-Jian
Ni, Ming-Yang
Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title_full Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title_fullStr Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title_full_unstemmed Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title_short Piezoelectric Actuated Phase Shifter Based on External Laser Interferometer: Design, Control and Experimental Validation
title_sort piezoelectric actuated phase shifter based on external laser interferometer: design, control and experimental validation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422199/
https://www.ncbi.nlm.nih.gov/pubmed/28398244
http://dx.doi.org/10.3390/s17040838
work_keys_str_mv AT lipengzhi piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT wangxiaodong piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT suiyongxin piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT zhangdefu piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT wangdongfang piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT donglijian piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation
AT nimingyang piezoelectricactuatedphaseshifterbasedonexternallaserinterferometerdesigncontrolandexperimentalvalidation