Cargando…

A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses

BACKGROUND: Load cells are often used in rehabilitation robotics to monitor human–robot interaction. While load cells are accurate and suitable for the stationary end-point robots used in rehabilitation hospitals, their cost and inability to conform to the shape of the body hinder their application...

Descripción completa

Detalles Bibliográficos
Autores principales: Alavi, N., Zampierin, S., Komeili, M., Cocuzza, S., Debei, S., Menon, C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422883/
https://www.ncbi.nlm.nih.gov/pubmed/28482892
http://dx.doi.org/10.1186/s12938-017-0345-8
_version_ 1783234849964818432
author Alavi, N.
Zampierin, S.
Komeili, M.
Cocuzza, S.
Debei, S.
Menon, C.
author_facet Alavi, N.
Zampierin, S.
Komeili, M.
Cocuzza, S.
Debei, S.
Menon, C.
author_sort Alavi, N.
collection PubMed
description BACKGROUND: Load cells are often used in rehabilitation robotics to monitor human–robot interaction. While load cells are accurate and suitable for the stationary end-point robots used in rehabilitation hospitals, their cost and inability to conform to the shape of the body hinder their application in developing affordable and wearable robotic orthoses for assisting individuals in the activities of daily living. This exploratory work investigates the possibility of using an alternative technology, namely compliant polymeric air cushions, to measure interaction forces between the user and a wearable rigid structure. METHODS: A polymeric air cushion was designed, analyzed using a finite element model (FEM), and tested using a bench-top characterization system. The cushions underwent repeatability testing, and signal delay testing from a step response while increasing the length of the cushion’s tubes. Subsequently, a 3D printed wrist brace prototype was integrated with six polymeric air cushions and tested in static conditions where a volunteer exerted isometric pronation/supination torque and forces in vertical and horizontal directions. The load measured by integrating data recorded by the six sensors was compared with force data measured by a high quality load cell and torque sensor. RESULTS: The FEM and experimental data comparison was within the error bounds of the external differential pressure sensor used to monitor the pressure inside the cushion. The ratio obtained experimentally between the pressure inside the pressure cushion and the 8 N applied load deviated by only 1.28% from the FEM. A drift smaller than 1% was observed over 10 cycles. The rise times of the cushion under an 8 N step response for a 0.46, 1.03, and 2.02 m length tube was 0.45, 0.39, and 0.37 s. Tests with the wrist brace showed a moderate root mean square error (RMSE) between the force estimated by the pressure cushions and the external load cells. Specifically, the RMSE was 13 mNm, 500 mN, and 1.24 N for forearm pronation/supination torque, vertical force, and horizontal force, respectively. CONCLUSIONS: The use of compliant pressure cushions was shown to be promising for monitoring interaction forces between the forearm and a rigid brace. This work lays the foundation for the future design of an array of pressure cushions for robotic orthoses. Future research should also investigate the compatibility of these polymeric cushions for data acquisition during functional magnetic resonance imaging in shielded rooms.
format Online
Article
Text
id pubmed-5422883
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54228832017-05-12 A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses Alavi, N. Zampierin, S. Komeili, M. Cocuzza, S. Debei, S. Menon, C. Biomed Eng Online Research BACKGROUND: Load cells are often used in rehabilitation robotics to monitor human–robot interaction. While load cells are accurate and suitable for the stationary end-point robots used in rehabilitation hospitals, their cost and inability to conform to the shape of the body hinder their application in developing affordable and wearable robotic orthoses for assisting individuals in the activities of daily living. This exploratory work investigates the possibility of using an alternative technology, namely compliant polymeric air cushions, to measure interaction forces between the user and a wearable rigid structure. METHODS: A polymeric air cushion was designed, analyzed using a finite element model (FEM), and tested using a bench-top characterization system. The cushions underwent repeatability testing, and signal delay testing from a step response while increasing the length of the cushion’s tubes. Subsequently, a 3D printed wrist brace prototype was integrated with six polymeric air cushions and tested in static conditions where a volunteer exerted isometric pronation/supination torque and forces in vertical and horizontal directions. The load measured by integrating data recorded by the six sensors was compared with force data measured by a high quality load cell and torque sensor. RESULTS: The FEM and experimental data comparison was within the error bounds of the external differential pressure sensor used to monitor the pressure inside the cushion. The ratio obtained experimentally between the pressure inside the pressure cushion and the 8 N applied load deviated by only 1.28% from the FEM. A drift smaller than 1% was observed over 10 cycles. The rise times of the cushion under an 8 N step response for a 0.46, 1.03, and 2.02 m length tube was 0.45, 0.39, and 0.37 s. Tests with the wrist brace showed a moderate root mean square error (RMSE) between the force estimated by the pressure cushions and the external load cells. Specifically, the RMSE was 13 mNm, 500 mN, and 1.24 N for forearm pronation/supination torque, vertical force, and horizontal force, respectively. CONCLUSIONS: The use of compliant pressure cushions was shown to be promising for monitoring interaction forces between the forearm and a rigid brace. This work lays the foundation for the future design of an array of pressure cushions for robotic orthoses. Future research should also investigate the compatibility of these polymeric cushions for data acquisition during functional magnetic resonance imaging in shielded rooms. BioMed Central 2017-05-08 /pmc/articles/PMC5422883/ /pubmed/28482892 http://dx.doi.org/10.1186/s12938-017-0345-8 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Alavi, N.
Zampierin, S.
Komeili, M.
Cocuzza, S.
Debei, S.
Menon, C.
A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title_full A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title_fullStr A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title_full_unstemmed A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title_short A preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
title_sort preliminary investigation into the design of pressure cushions and their potential applications for forearm robotic orthoses
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5422883/
https://www.ncbi.nlm.nih.gov/pubmed/28482892
http://dx.doi.org/10.1186/s12938-017-0345-8
work_keys_str_mv AT alavin apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT zampierins apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT komeilim apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT cocuzzas apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT debeis apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT menonc apreliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT alavin preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT zampierins preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT komeilim preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT cocuzzas preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT debeis preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses
AT menonc preliminaryinvestigationintothedesignofpressurecushionsandtheirpotentialapplicationsforforearmroboticorthoses