Cargando…
Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial
The combined use of a drug-eluting balloon (DEB) and a bare metal stent (BMS) for the treatment of de novo non-small vessel coronary artery diseases (CAD) remains to be evaluated. We investigated the efficacy of a sequential treatment using a DEB together with a BMS implantation in comparison to a z...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Academy of Medical Sciences
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426232/ https://www.ncbi.nlm.nih.gov/pubmed/28480650 http://dx.doi.org/10.3346/jkms.2017.32.6.933 |
_version_ | 1783235431288012800 |
---|---|
author | Chae, In-Ho Yoon, Chang-Hwan Park, Jin Joo Oh, Il-Young Suh, Jung-Won Cho, Young-Seok Youn, Tae-Jin Choi, Dong-Ju |
author_facet | Chae, In-Ho Yoon, Chang-Hwan Park, Jin Joo Oh, Il-Young Suh, Jung-Won Cho, Young-Seok Youn, Tae-Jin Choi, Dong-Ju |
author_sort | Chae, In-Ho |
collection | PubMed |
description | The combined use of a drug-eluting balloon (DEB) and a bare metal stent (BMS) for the treatment of de novo non-small vessel coronary artery diseases (CAD) remains to be evaluated. We investigated the efficacy of a sequential treatment using a DEB together with a BMS implantation in comparison to a zotarolimus-eluting stent (ZES). This study was a prospective, randomized, open-label study. We designed it to demonstrate the non-inferiority of a sequential treatment using a DEB first followed by a BMS (DEB + BMS) compared with the use of a ZES. The primary endpoint was in-segment late loss (LL) at 9 months measured by quantitative coronary angiography (QCA). A total of 180 patients were enrolled in the study. The 9-month follow-up angiography was performed in 72 patients with DEB + BMS and 74 patients with ZES. When comparing the DEB + BMS results with the ZES ones, LL was 0.50 ± 0.46 mm in DEB + BMS patients vs. 0.21 ± 0.44 mm in ZES patients (P < 0.001). The mean difference of the LL was 0.31 mm, which was larger than the prespecified non-inferiority margin of 0.19 mm, and the 2-sided 95% confidence interval was 0.15–0.48. The clinical outcomes were not significantly different. In conclusion, the DEB + BMS strategy is inferior to the ZES one in terms of the LL result at 9 months. The DEB strategy for de novo coronary artery lesions needs to be improved for it to become an alternative treatment option. This was a clinical trial study and was registered at www.ClinicalTrials.gov (Identifier: NCT01539603; http://www.clinicaltrials.gov/ct2/show/NCT01539603). |
format | Online Article Text |
id | pubmed-5426232 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Academy of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-54262322017-06-01 Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial Chae, In-Ho Yoon, Chang-Hwan Park, Jin Joo Oh, Il-Young Suh, Jung-Won Cho, Young-Seok Youn, Tae-Jin Choi, Dong-Ju J Korean Med Sci Original Article The combined use of a drug-eluting balloon (DEB) and a bare metal stent (BMS) for the treatment of de novo non-small vessel coronary artery diseases (CAD) remains to be evaluated. We investigated the efficacy of a sequential treatment using a DEB together with a BMS implantation in comparison to a zotarolimus-eluting stent (ZES). This study was a prospective, randomized, open-label study. We designed it to demonstrate the non-inferiority of a sequential treatment using a DEB first followed by a BMS (DEB + BMS) compared with the use of a ZES. The primary endpoint was in-segment late loss (LL) at 9 months measured by quantitative coronary angiography (QCA). A total of 180 patients were enrolled in the study. The 9-month follow-up angiography was performed in 72 patients with DEB + BMS and 74 patients with ZES. When comparing the DEB + BMS results with the ZES ones, LL was 0.50 ± 0.46 mm in DEB + BMS patients vs. 0.21 ± 0.44 mm in ZES patients (P < 0.001). The mean difference of the LL was 0.31 mm, which was larger than the prespecified non-inferiority margin of 0.19 mm, and the 2-sided 95% confidence interval was 0.15–0.48. The clinical outcomes were not significantly different. In conclusion, the DEB + BMS strategy is inferior to the ZES one in terms of the LL result at 9 months. The DEB strategy for de novo coronary artery lesions needs to be improved for it to become an alternative treatment option. This was a clinical trial study and was registered at www.ClinicalTrials.gov (Identifier: NCT01539603; http://www.clinicaltrials.gov/ct2/show/NCT01539603). The Korean Academy of Medical Sciences 2017-06 2017-04-14 /pmc/articles/PMC5426232/ /pubmed/28480650 http://dx.doi.org/10.3346/jkms.2017.32.6.933 Text en © 2017 The Korean Academy of Medical Sciences. https://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Chae, In-Ho Yoon, Chang-Hwan Park, Jin Joo Oh, Il-Young Suh, Jung-Won Cho, Young-Seok Youn, Tae-Jin Choi, Dong-Ju Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title | Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title_full | Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title_fullStr | Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title_full_unstemmed | Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title_short | Comparison of Drug-Eluting Balloon Followed by Bare Metal Stent with Drug-Eluting Stent for Treatment of de Novo Lesions: Randomized, Controlled, Single-Center Clinical Trial |
title_sort | comparison of drug-eluting balloon followed by bare metal stent with drug-eluting stent for treatment of de novo lesions: randomized, controlled, single-center clinical trial |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426232/ https://www.ncbi.nlm.nih.gov/pubmed/28480650 http://dx.doi.org/10.3346/jkms.2017.32.6.933 |
work_keys_str_mv | AT chaeinho comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT yoonchanghwan comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT parkjinjoo comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT ohilyoung comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT suhjungwon comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT choyoungseok comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT yountaejin comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial AT choidongju comparisonofdrugelutingballoonfollowedbybaremetalstentwithdrugelutingstentfortreatmentofdenovolesionsrandomizedcontrolledsinglecenterclinicaltrial |