Cargando…
Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study
OBJECTIVE: To investigate the feasibility of a knee proprioception evaluation using a dynamometer as a tool for evaluating proprioception of the lower extremities in patients with incomplete spinal cord injury (SCI), and to explore its usefulness in predicting the ambulatory outcome. METHODS: A tota...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426262/ https://www.ncbi.nlm.nih.gov/pubmed/28503454 http://dx.doi.org/10.5535/arm.2017.41.2.218 |
_version_ | 1783235438959394816 |
---|---|
author | Chang, Won Kee Jung, Yun Suk Oh, Mi-Kyoung Kim, Keewon |
author_facet | Chang, Won Kee Jung, Yun Suk Oh, Mi-Kyoung Kim, Keewon |
author_sort | Chang, Won Kee |
collection | PubMed |
description | OBJECTIVE: To investigate the feasibility of a knee proprioception evaluation using a dynamometer as a tool for evaluating proprioception of the lower extremities in patients with incomplete spinal cord injury (SCI), and to explore its usefulness in predicting the ambulatory outcome. METHODS: A total of 14 SCI patients (10 tetraplegic, 4 paraplegic; all AIS D) were included in this study. The passive repositioning error (PRE) and active repositioning error (ARE) were measured with a dynamometer, along with tibial somatosensory evoked potential (SSEP) and abductor hallucis motor-evoked potential (MEP). Ambulatory capacity was assessed with the Walking Index for Spinal Cord Injury II (WISCI-II), both at the time of the proprioception test (WISCI_i) and at least 6 months after the test (WISCI_6mo). RESULTS: The PRE showed a negative correlation with WISCI_i (r=-0.440, p=0.034) and WISCI_6mo (r=-0.568, p=0.010). Linear multiple regression showed the type of injury, lower extremities motor score, MEP, and PRE accounted for 75.4% of the WISCI_6mo variance (p=0.080). CONCLUSION: Proprioception of the knee can be measured quantitatively with a dynamometer in patients with incomplete SCI, and PRE was related to the outcome of the ambulatory capacity. Along with the neurological and electrophysiological examinations, a proprioception test using a dynamometer may have supplementary value in predicting the ambulatory capacity in patients with incomplete SCI. |
format | Online Article Text |
id | pubmed-5426262 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Academy of Rehabilitation Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-54262622017-05-12 Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study Chang, Won Kee Jung, Yun Suk Oh, Mi-Kyoung Kim, Keewon Ann Rehabil Med Original Article OBJECTIVE: To investigate the feasibility of a knee proprioception evaluation using a dynamometer as a tool for evaluating proprioception of the lower extremities in patients with incomplete spinal cord injury (SCI), and to explore its usefulness in predicting the ambulatory outcome. METHODS: A total of 14 SCI patients (10 tetraplegic, 4 paraplegic; all AIS D) were included in this study. The passive repositioning error (PRE) and active repositioning error (ARE) were measured with a dynamometer, along with tibial somatosensory evoked potential (SSEP) and abductor hallucis motor-evoked potential (MEP). Ambulatory capacity was assessed with the Walking Index for Spinal Cord Injury II (WISCI-II), both at the time of the proprioception test (WISCI_i) and at least 6 months after the test (WISCI_6mo). RESULTS: The PRE showed a negative correlation with WISCI_i (r=-0.440, p=0.034) and WISCI_6mo (r=-0.568, p=0.010). Linear multiple regression showed the type of injury, lower extremities motor score, MEP, and PRE accounted for 75.4% of the WISCI_6mo variance (p=0.080). CONCLUSION: Proprioception of the knee can be measured quantitatively with a dynamometer in patients with incomplete SCI, and PRE was related to the outcome of the ambulatory capacity. Along with the neurological and electrophysiological examinations, a proprioception test using a dynamometer may have supplementary value in predicting the ambulatory capacity in patients with incomplete SCI. Korean Academy of Rehabilitation Medicine 2017-04 2017-04-27 /pmc/articles/PMC5426262/ /pubmed/28503454 http://dx.doi.org/10.5535/arm.2017.41.2.218 Text en Copyright © 2017 by Korean Academy of Rehabilitation Medicine http://creativecommons.org/licenses/by-nc/4.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Chang, Won Kee Jung, Yun Suk Oh, Mi-Kyoung Kim, Keewon Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title | Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title_full | Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title_fullStr | Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title_full_unstemmed | Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title_short | Quantitative Assessment of Proprioception Using Dynamometer in Incomplete Spinal Cord Injury Patients: A Preliminary Study |
title_sort | quantitative assessment of proprioception using dynamometer in incomplete spinal cord injury patients: a preliminary study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426262/ https://www.ncbi.nlm.nih.gov/pubmed/28503454 http://dx.doi.org/10.5535/arm.2017.41.2.218 |
work_keys_str_mv | AT changwonkee quantitativeassessmentofproprioceptionusingdynamometerinincompletespinalcordinjurypatientsapreliminarystudy AT jungyunsuk quantitativeassessmentofproprioceptionusingdynamometerinincompletespinalcordinjurypatientsapreliminarystudy AT ohmikyoung quantitativeassessmentofproprioceptionusingdynamometerinincompletespinalcordinjurypatientsapreliminarystudy AT kimkeewon quantitativeassessmentofproprioceptionusingdynamometerinincompletespinalcordinjurypatientsapreliminarystudy |