Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array

The importance of Non-Destructive Testing (NDT) to check the integrity of materials in different fields of industry has increased significantly in recent years. Actually, industry demands NDT methods that allow fast (preferably non-contact) detection and localization of early-stage defects with easy...

Descripción completa

Detalles Bibliográficos
Autores principales: Delrue, Steven, Aleshin, Vladislav, Sørensen, Mikael, De Lathauwer, Lieven
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426926/
https://www.ncbi.nlm.nih.gov/pubmed/28441738
http://dx.doi.org/10.3390/s17040930
_version_ 1783235581806903296
author Delrue, Steven
Aleshin, Vladislav
Sørensen, Mikael
De Lathauwer, Lieven
author_facet Delrue, Steven
Aleshin, Vladislav
Sørensen, Mikael
De Lathauwer, Lieven
author_sort Delrue, Steven
collection PubMed
description The importance of Non-Destructive Testing (NDT) to check the integrity of materials in different fields of industry has increased significantly in recent years. Actually, industry demands NDT methods that allow fast (preferably non-contact) detection and localization of early-stage defects with easy-to-interpret results, so that even a non-expert field worker can carry out the testing. The main challenge is to combine as many of these requirements into one single technique. The concept of acoustic cameras, developed for low frequency NDT, meets most of the above-mentioned requirements. These cameras make use of an array of microphones to visualize noise sources by estimating the Direction Of Arrival (DOA) of the impinging sound waves. Until now, however, because of limitations in the frequency range and the lack of integrated nonlinear post-processing, acoustic camera systems have never been used for the localization of incipient damage. The goal of the current paper is to numerically investigate the capabilities of locating incipient damage by measuring the nonlinear airborne emission of the defect using a non-contact ultrasonic sensor array. We will consider a simple case of a sample with a single near-surface crack and prove that after efficient excitation of the defect sample, the nonlinear defect responses can be detected by a uniform linear sensor array. These responses are then used to determine the location of the defect by means of three different DOA algorithms. The results obtained in this study can be considered as a first step towards the development of a nonlinear ultrasonic camera system, comprising the ultrasonic sensor array as the hardware and nonlinear post-processing and source localization software.
format Online
Article
Text
id pubmed-5426926
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54269262017-05-12 Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array Delrue, Steven Aleshin, Vladislav Sørensen, Mikael De Lathauwer, Lieven Sensors (Basel) Article The importance of Non-Destructive Testing (NDT) to check the integrity of materials in different fields of industry has increased significantly in recent years. Actually, industry demands NDT methods that allow fast (preferably non-contact) detection and localization of early-stage defects with easy-to-interpret results, so that even a non-expert field worker can carry out the testing. The main challenge is to combine as many of these requirements into one single technique. The concept of acoustic cameras, developed for low frequency NDT, meets most of the above-mentioned requirements. These cameras make use of an array of microphones to visualize noise sources by estimating the Direction Of Arrival (DOA) of the impinging sound waves. Until now, however, because of limitations in the frequency range and the lack of integrated nonlinear post-processing, acoustic camera systems have never been used for the localization of incipient damage. The goal of the current paper is to numerically investigate the capabilities of locating incipient damage by measuring the nonlinear airborne emission of the defect using a non-contact ultrasonic sensor array. We will consider a simple case of a sample with a single near-surface crack and prove that after efficient excitation of the defect sample, the nonlinear defect responses can be detected by a uniform linear sensor array. These responses are then used to determine the location of the defect by means of three different DOA algorithms. The results obtained in this study can be considered as a first step towards the development of a nonlinear ultrasonic camera system, comprising the ultrasonic sensor array as the hardware and nonlinear post-processing and source localization software. MDPI 2017-04-22 /pmc/articles/PMC5426926/ /pubmed/28441738 http://dx.doi.org/10.3390/s17040930 Text en © 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Delrue, Steven
Aleshin, Vladislav
Sørensen, Mikael
De Lathauwer, Lieven
Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title_full Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title_fullStr Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title_full_unstemmed Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title_short Simulation Study of the Localization of a Near-Surface Crack Using an Air-Coupled Ultrasonic Sensor Array
title_sort simulation study of the localization of a near-surface crack using an air-coupled ultrasonic sensor array
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5426926/
https://www.ncbi.nlm.nih.gov/pubmed/28441738
http://dx.doi.org/10.3390/s17040930
work_keys_str_mv AT delruesteven simulationstudyofthelocalizationofanearsurfacecrackusinganaircoupledultrasonicsensorarray
AT aleshinvladislav simulationstudyofthelocalizationofanearsurfacecrackusinganaircoupledultrasonicsensorarray
AT sørensenmikael simulationstudyofthelocalizationofanearsurfacecrackusinganaircoupledultrasonicsensorarray
AT delathauwerlieven simulationstudyofthelocalizationofanearsurfacecrackusinganaircoupledultrasonicsensorarray