Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings

PURPOSE: The reliability of surface electromyography (sEMG) is typically modest even with rigorous methods, and therefore further improvements in sEMG reliability are desirable. This study compared the between-session reliability (both within participant absolute reliability and between-participant...

Descripción completa

Detalles Bibliográficos
Autores principales: Balshaw, T. G., Fry, A., Maden-Wilkinson, T. M., Kong, P. W., Folland, J. P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5427161/
https://www.ncbi.nlm.nih.gov/pubmed/28391392
http://dx.doi.org/10.1007/s00421-017-3595-z
Descripción
Sumario:PURPOSE: The reliability of surface electromyography (sEMG) is typically modest even with rigorous methods, and therefore further improvements in sEMG reliability are desirable. This study compared the between-session reliability (both within participant absolute reliability and between-participant relative reliability) of sEMG amplitude from single vs. average of two distinct recording sites, for individual muscle (IM) and whole quadriceps (WQ) measures during voluntary and evoked contractions. METHODS: Healthy males (n = 20) performed unilateral isometric knee extension contractions: voluntary maximum and submaximum (60%), as well as evoked twitch contractions on two separate days. sEMG was recorded from two distinct sites on each superficial quadriceps muscle. RESULTS: Averaging two recording sites vs. using single site measures improved reliability for IM and WQ measurements during voluntary (16–26% reduction in within-participant coefficient of variation, CV(W)) and evoked contractions (40–56% reduction in CV(W)). CONCLUSIONS: For sEMG measurements from large muscles, averaging the recording of two distinct sites is recommended as it improves within-participant reliability. This improved sensitivity has application to clinical and research measurement of sEMG amplitude.