Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles
Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429396/ https://www.ncbi.nlm.nih.gov/pubmed/28285060 http://dx.doi.org/10.1016/j.jmbbm.2017.03.006 |
_version_ | 1783236006958333952 |
---|---|
author | Peters, Abby E. Comerford, Eithne J. Macaulay, Sophie Bates, Karl T. Akhtar, Riaz |
author_facet | Peters, Abby E. Comerford, Eithne J. Macaulay, Sophie Bates, Karl T. Akhtar, Riaz |
author_sort | Peters, Abby E. |
collection | PubMed |
description | Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which the material properties of articular cartilage are altered by repetitive freezing have not been explored. Therefore, the aim of this study is to quantify how articular cartilage mechanical properties, measured by nanoindentation, are affected by multiple freeze-thaw cycles. Canine cartilage plugs (n = 11) from medial and lateral femoral condyles were submerged in phosphate buffered saline, stored at 3–5 °C and tested using nanoindentation within 12 h. Samples were then frozen at −20 °C and later thawed at 3–5 °C for 3 h before material properties were re-tested and samples re-frozen under the same conditions. This process was repeated for all 11 samples over three freeze-thaw cycles. Overall mean and standard deviation of shear storage modulus decreased from 1.76 ± 0.78 to 1.21 ± 0.77 MPa (p = 0.91), shear loss modulus from 0.42 ± 0.19 to 0.39 ± 0.17 MPa (p=0.70) and elastic modulus from 5.13 ± 2.28 to 3.52 ± 2.24 MPa (p = 0.20) between fresh and three freeze-thaw cycles respectively. The loss factor increased from 0.31 ± 0.38 to 0.71 ± 1.40 (p = 0.18) between fresh and three freeze-thaw cycles. Inter-sample variability spanned as much as 10.47 MPa across freezing cycles and this high-level of biological variability across samples likely explains why overall mean “whole-joint” trends do not reach statistical significance across the storage conditions tested. As a result multiple freeze-thaw cycles cannot be explicitly or statistically linked to mechanical changes within the cartilage. However, the changes in material properties observed herein may be sufficient in magnitude to impact on a variety of clinical and scientific studies of cartilage, and should be considered when planning experimental protocols. |
format | Online Article Text |
id | pubmed-5429396 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-54293962017-07-01 Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles Peters, Abby E. Comerford, Eithne J. Macaulay, Sophie Bates, Karl T. Akhtar, Riaz J Mech Behav Biomed Mater Article Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which the material properties of articular cartilage are altered by repetitive freezing have not been explored. Therefore, the aim of this study is to quantify how articular cartilage mechanical properties, measured by nanoindentation, are affected by multiple freeze-thaw cycles. Canine cartilage plugs (n = 11) from medial and lateral femoral condyles were submerged in phosphate buffered saline, stored at 3–5 °C and tested using nanoindentation within 12 h. Samples were then frozen at −20 °C and later thawed at 3–5 °C for 3 h before material properties were re-tested and samples re-frozen under the same conditions. This process was repeated for all 11 samples over three freeze-thaw cycles. Overall mean and standard deviation of shear storage modulus decreased from 1.76 ± 0.78 to 1.21 ± 0.77 MPa (p = 0.91), shear loss modulus from 0.42 ± 0.19 to 0.39 ± 0.17 MPa (p=0.70) and elastic modulus from 5.13 ± 2.28 to 3.52 ± 2.24 MPa (p = 0.20) between fresh and three freeze-thaw cycles respectively. The loss factor increased from 0.31 ± 0.38 to 0.71 ± 1.40 (p = 0.18) between fresh and three freeze-thaw cycles. Inter-sample variability spanned as much as 10.47 MPa across freezing cycles and this high-level of biological variability across samples likely explains why overall mean “whole-joint” trends do not reach statistical significance across the storage conditions tested. As a result multiple freeze-thaw cycles cannot be explicitly or statistically linked to mechanical changes within the cartilage. However, the changes in material properties observed herein may be sufficient in magnitude to impact on a variety of clinical and scientific studies of cartilage, and should be considered when planning experimental protocols. Elsevier 2017-07 /pmc/articles/PMC5429396/ /pubmed/28285060 http://dx.doi.org/10.1016/j.jmbbm.2017.03.006 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Peters, Abby E. Comerford, Eithne J. Macaulay, Sophie Bates, Karl T. Akhtar, Riaz Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title | Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title_full | Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title_fullStr | Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title_full_unstemmed | Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title_short | Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
title_sort | micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429396/ https://www.ncbi.nlm.nih.gov/pubmed/28285060 http://dx.doi.org/10.1016/j.jmbbm.2017.03.006 |
work_keys_str_mv | AT petersabbye micromechanicalpropertiesofcaninefemoralarticularcartilagefollowingmultiplefreezethawcycles AT comerfordeithnej micromechanicalpropertiesofcaninefemoralarticularcartilagefollowingmultiplefreezethawcycles AT macaulaysophie micromechanicalpropertiesofcaninefemoralarticularcartilagefollowingmultiplefreezethawcycles AT bateskarlt micromechanicalpropertiesofcaninefemoralarticularcartilagefollowingmultiplefreezethawcycles AT akhtarriaz micromechanicalpropertiesofcaninefemoralarticularcartilagefollowingmultiplefreezethawcycles |