Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry
BACKGROUND: Femoral component malrotation is a common cause of patient dissatisfaction after total knee arthroplasty. The sulcus line (SL) is more accurate than Whiteside’s line as it corrects for variation in the coronal orientation of the groove. The hypothesis is that averaging the SL and posteri...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429545/ https://www.ncbi.nlm.nih.gov/pubmed/28499396 http://dx.doi.org/10.1186/s13018-017-0575-2 |
_version_ | 1783236043597676544 |
---|---|
author | Chao, Tat Woon Geraghty, Liam Dimitriou, Pandelis Talbot, Simon |
author_facet | Chao, Tat Woon Geraghty, Liam Dimitriou, Pandelis Talbot, Simon |
author_sort | Chao, Tat Woon |
collection | PubMed |
description | BACKGROUND: Femoral component malrotation is a common cause of patient dissatisfaction after total knee arthroplasty. The sulcus line (SL) is more accurate than Whiteside’s line as it corrects for variation in the coronal orientation of the groove. The hypothesis is that averaging the SL and posterior condylar axis (PCA) will reduce femoral malrotation. METHODS: The component was inserted at a position between the SL and PCA in 91 patients. An intraoperative photograph was taken showing the landmarks. These were compared to the component position achieved relative to the surgical epicondylar axis (SEA) on a postoperative CT scan. The component position was compared to the position achieved using the individual landmarks. RESULTS: Relative to the SEA, the final component position was 0.6° (SD 1.4°, range −3.8° to +4.0°), the coronally corrected SL position was −0.7° (SD 2.3°, −5.5° to +4.6°), the PCA position was 0.9° (SD 1.9°, −6.1° to +5.0°). Averaging the landmarks significantly decreased the variance of the component position compared to using the SL and PCA individually. The number of outliers (>3° from SEA) was also significantly less (p < 0.05) for the average position (2/84) when each was compared to the SL (16/84) and PCA (14/84) individually. In 21/84 (25%) of cases, there was more than 4° of divergence between the SL and PCA. CONCLUSIONS: Averaging the SL and the PCA decreases femoral component malrotation. Femora are frequently asymmetrical in the axial plane. Referencing posterior condyles alone to set rotation is likely to cause high rates of patellofemoral malalignment. |
format | Online Article Text |
id | pubmed-5429545 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54295452017-05-15 Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry Chao, Tat Woon Geraghty, Liam Dimitriou, Pandelis Talbot, Simon J Orthop Surg Res Research Article BACKGROUND: Femoral component malrotation is a common cause of patient dissatisfaction after total knee arthroplasty. The sulcus line (SL) is more accurate than Whiteside’s line as it corrects for variation in the coronal orientation of the groove. The hypothesis is that averaging the SL and posterior condylar axis (PCA) will reduce femoral malrotation. METHODS: The component was inserted at a position between the SL and PCA in 91 patients. An intraoperative photograph was taken showing the landmarks. These were compared to the component position achieved relative to the surgical epicondylar axis (SEA) on a postoperative CT scan. The component position was compared to the position achieved using the individual landmarks. RESULTS: Relative to the SEA, the final component position was 0.6° (SD 1.4°, range −3.8° to +4.0°), the coronally corrected SL position was −0.7° (SD 2.3°, −5.5° to +4.6°), the PCA position was 0.9° (SD 1.9°, −6.1° to +5.0°). Averaging the landmarks significantly decreased the variance of the component position compared to using the SL and PCA individually. The number of outliers (>3° from SEA) was also significantly less (p < 0.05) for the average position (2/84) when each was compared to the SL (16/84) and PCA (14/84) individually. In 21/84 (25%) of cases, there was more than 4° of divergence between the SL and PCA. CONCLUSIONS: Averaging the SL and the PCA decreases femoral component malrotation. Femora are frequently asymmetrical in the axial plane. Referencing posterior condyles alone to set rotation is likely to cause high rates of patellofemoral malalignment. BioMed Central 2017-05-12 /pmc/articles/PMC5429545/ /pubmed/28499396 http://dx.doi.org/10.1186/s13018-017-0575-2 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Chao, Tat Woon Geraghty, Liam Dimitriou, Pandelis Talbot, Simon Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title | Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title_full | Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title_fullStr | Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title_full_unstemmed | Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title_short | Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
title_sort | averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429545/ https://www.ncbi.nlm.nih.gov/pubmed/28499396 http://dx.doi.org/10.1186/s13018-017-0575-2 |
work_keys_str_mv | AT chaotatwoon averagingrotationallandmarksduringtotalkneearthroplastyreducescomponentmalrotationcausedbyfemoralasymmetry AT geraghtyliam averagingrotationallandmarksduringtotalkneearthroplastyreducescomponentmalrotationcausedbyfemoralasymmetry AT dimitrioupandelis averagingrotationallandmarksduringtotalkneearthroplastyreducescomponentmalrotationcausedbyfemoralasymmetry AT talbotsimon averagingrotationallandmarksduringtotalkneearthroplastyreducescomponentmalrotationcausedbyfemoralasymmetry |