Cargando…

Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation

This work presents an evaluation study using a force feedback evaluation framework for a novel direct needle force volume rendering concept in the context of liver puncture simulation. PTC/PTCD puncture interventions targeting the bile ducts have been selected to illustrate this concept. The haptic...

Descripción completa

Detalles Bibliográficos
Autores principales: Mastmeyer, Andre, Fortmeier, Dirk, Handels, Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429645/
https://www.ncbi.nlm.nih.gov/pubmed/28386067
http://dx.doi.org/10.1038/s41598-017-00746-z
_version_ 1783236066750234624
author Mastmeyer, Andre
Fortmeier, Dirk
Handels, Heinz
author_facet Mastmeyer, Andre
Fortmeier, Dirk
Handels, Heinz
author_sort Mastmeyer, Andre
collection PubMed
description This work presents an evaluation study using a force feedback evaluation framework for a novel direct needle force volume rendering concept in the context of liver puncture simulation. PTC/PTCD puncture interventions targeting the bile ducts have been selected to illustrate this concept. The haptic algorithms of the simulator system are based on (1) partially segmented patient image data and (2) a non-linear spring model effective at organ borders. The primary aim is to quantitatively evaluate force errors caused by our patient modeling approach, in comparison to haptic force output obtained from using gold-standard, completely manually-segmented data. The evaluation of the force algorithms compared to a force output from fully manually segmented gold-standard patient models, yields a low mean of 0.12 N root mean squared force error and up to 1.6 N for systematic maximum absolute errors. Force errors were evaluated on 31,222 preplanned test paths from 10 patients. Only twelve percent of the emitted forces along these paths were affected by errors. This is the first study evaluating haptic algorithms with deformable virtual patients in silico. We prove haptic rendering plausibility on a very high number of test paths. Important errors are below just noticeable differences for the hand-arm system.
format Online
Article
Text
id pubmed-5429645
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-54296452017-05-15 Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation Mastmeyer, Andre Fortmeier, Dirk Handels, Heinz Sci Rep Article This work presents an evaluation study using a force feedback evaluation framework for a novel direct needle force volume rendering concept in the context of liver puncture simulation. PTC/PTCD puncture interventions targeting the bile ducts have been selected to illustrate this concept. The haptic algorithms of the simulator system are based on (1) partially segmented patient image data and (2) a non-linear spring model effective at organ borders. The primary aim is to quantitatively evaluate force errors caused by our patient modeling approach, in comparison to haptic force output obtained from using gold-standard, completely manually-segmented data. The evaluation of the force algorithms compared to a force output from fully manually segmented gold-standard patient models, yields a low mean of 0.12 N root mean squared force error and up to 1.6 N for systematic maximum absolute errors. Force errors were evaluated on 31,222 preplanned test paths from 10 patients. Only twelve percent of the emitted forces along these paths were affected by errors. This is the first study evaluating haptic algorithms with deformable virtual patients in silico. We prove haptic rendering plausibility on a very high number of test paths. Important errors are below just noticeable differences for the hand-arm system. Nature Publishing Group UK 2017-04-06 /pmc/articles/PMC5429645/ /pubmed/28386067 http://dx.doi.org/10.1038/s41598-017-00746-z Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Mastmeyer, Andre
Fortmeier, Dirk
Handels, Heinz
Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title_full Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title_fullStr Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title_full_unstemmed Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title_short Evaluation of Direct Haptic 4D Volume Rendering of Partially Segmented Data for Liver Puncture Simulation
title_sort evaluation of direct haptic 4d volume rendering of partially segmented data for liver puncture simulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429645/
https://www.ncbi.nlm.nih.gov/pubmed/28386067
http://dx.doi.org/10.1038/s41598-017-00746-z
work_keys_str_mv AT mastmeyerandre evaluationofdirecthaptic4dvolumerenderingofpartiallysegmenteddataforliverpuncturesimulation
AT fortmeierdirk evaluationofdirecthaptic4dvolumerenderingofpartiallysegmenteddataforliverpuncturesimulation
AT handelsheinz evaluationofdirecthaptic4dvolumerenderingofpartiallysegmenteddataforliverpuncturesimulation