Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection

We are presenting a case report of failed valve-in-valve treatment of severe aortic stenosis. A control ultrasonography after TAVI implantation revealed a severe aortic regurgitation of the graft which was subsequently unresolved with postimplantation dilatation. Second TAVI was implanted with crani...

Descripción completa

Detalles Bibliográficos
Autores principales: Novotný, Róbert, Hlubocký, Jaroslav, Kovárník, Tomáš, Mitáš, Petr, Hlubocka, Zuzana, Rulíšek, Jan, Gulmez, Sevim Ismihan, Ghotra, Shubjiwan Kaur, Lindner, Jaroslav
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429917/
https://www.ncbi.nlm.nih.gov/pubmed/28540089
http://dx.doi.org/10.1155/2017/5086586
_version_ 1783236126833639424
author Novotný, Róbert
Hlubocký, Jaroslav
Kovárník, Tomáš
Mitáš, Petr
Hlubocka, Zuzana
Rulíšek, Jan
Gulmez, Sevim Ismihan
Ghotra, Shubjiwan Kaur
Lindner, Jaroslav
author_facet Novotný, Róbert
Hlubocký, Jaroslav
Kovárník, Tomáš
Mitáš, Petr
Hlubocka, Zuzana
Rulíšek, Jan
Gulmez, Sevim Ismihan
Ghotra, Shubjiwan Kaur
Lindner, Jaroslav
author_sort Novotný, Róbert
collection PubMed
description We are presenting a case report of failed valve-in-valve treatment of severe aortic stenosis. A control ultrasonography after TAVI implantation revealed a severe aortic regurgitation of the graft which was subsequently unresolved with postimplantation dilatation. Second TAVI was implanted with cranial dislocation to the aortic root. Patient underwent a CT examination to clarify the TAVI in TAVI position. Patient underwent a surgical resection of TAVI with implantation of biological aortic valve prosthesis. In situations where TAVI treatment fails or is complicated beyond the possibility of endovascular repair, surgical intervention despite its higher risks is the preferred choice.
format Online
Article
Text
id pubmed-5429917
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54299172017-05-24 Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection Novotný, Róbert Hlubocký, Jaroslav Kovárník, Tomáš Mitáš, Petr Hlubocka, Zuzana Rulíšek, Jan Gulmez, Sevim Ismihan Ghotra, Shubjiwan Kaur Lindner, Jaroslav Case Rep Cardiol Case Report We are presenting a case report of failed valve-in-valve treatment of severe aortic stenosis. A control ultrasonography after TAVI implantation revealed a severe aortic regurgitation of the graft which was subsequently unresolved with postimplantation dilatation. Second TAVI was implanted with cranial dislocation to the aortic root. Patient underwent a CT examination to clarify the TAVI in TAVI position. Patient underwent a surgical resection of TAVI with implantation of biological aortic valve prosthesis. In situations where TAVI treatment fails or is complicated beyond the possibility of endovascular repair, surgical intervention despite its higher risks is the preferred choice. Hindawi 2017 2017-04-30 /pmc/articles/PMC5429917/ /pubmed/28540089 http://dx.doi.org/10.1155/2017/5086586 Text en Copyright © 2017 Róbert Novotný et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Novotný, Róbert
Hlubocký, Jaroslav
Kovárník, Tomáš
Mitáš, Petr
Hlubocka, Zuzana
Rulíšek, Jan
Gulmez, Sevim Ismihan
Ghotra, Shubjiwan Kaur
Lindner, Jaroslav
Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title_full Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title_fullStr Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title_full_unstemmed Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title_short Failed TAVI in TAVI Implantation: TAVI Dislocation Followed by Ensuing Surgical Graft Resection
title_sort failed tavi in tavi implantation: tavi dislocation followed by ensuing surgical graft resection
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5429917/
https://www.ncbi.nlm.nih.gov/pubmed/28540089
http://dx.doi.org/10.1155/2017/5086586
work_keys_str_mv AT novotnyrobert failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT hlubockyjaroslav failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT kovarniktomas failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT mitaspetr failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT hlubockazuzana failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT rulisekjan failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT gulmezsevimismihan failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT ghotrashubjiwankaur failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection
AT lindnerjaroslav failedtaviintaviimplantationtavidislocationfollowedbyensuingsurgicalgraftresection