Cargando…

Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood

The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we re...

Descripción completa

Detalles Bibliográficos
Autores principales: Eissa, Shimaa, Zourob, Mohammed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5430690/
https://www.ncbi.nlm.nih.gov/pubmed/28432344
http://dx.doi.org/10.1038/s41598-017-01226-0
_version_ 1783236271737405440
author Eissa, Shimaa
Zourob, Mohammed
author_facet Eissa, Shimaa
Zourob, Mohammed
author_sort Eissa, Shimaa
collection PubMed
description The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we report the selection, identification and characterization of specific DNA aptamers against HbA1c- and total hemoglobin (tHb) and their integration into an electrochemical array sensing platform. High affinity and specificity aptamers were selected in vitro showing dissociation constants of 2.8 and 2.7 nM for HbA1c and tHb, respectively. Thiol-modified forms of the aptamers were then immobilised on gold nanoparticles (AuNPs)-modified array electrodes and used for the label-free detection of HbA1c and tHb using square wave voltammetry. The voltammetric aptasensors showed high sensitivity with detection limits of 0.2 and 0.34 ng/ml for HbA1c and tHb, respectively. This array platform is superior to the currently available immunoassays in terms of simplicity, stability, ease of use, reduction of sample volume and low cost. Moreover, this method enabled the detection of HbA1c % in human whole blood without any pre-treatment, suggesting great promise of this platform for the diagnosis of diabetes.
format Online
Article
Text
id pubmed-5430690
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-54306902017-05-16 Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood Eissa, Shimaa Zourob, Mohammed Sci Rep Article The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we report the selection, identification and characterization of specific DNA aptamers against HbA1c- and total hemoglobin (tHb) and their integration into an electrochemical array sensing platform. High affinity and specificity aptamers were selected in vitro showing dissociation constants of 2.8 and 2.7 nM for HbA1c and tHb, respectively. Thiol-modified forms of the aptamers were then immobilised on gold nanoparticles (AuNPs)-modified array electrodes and used for the label-free detection of HbA1c and tHb using square wave voltammetry. The voltammetric aptasensors showed high sensitivity with detection limits of 0.2 and 0.34 ng/ml for HbA1c and tHb, respectively. This array platform is superior to the currently available immunoassays in terms of simplicity, stability, ease of use, reduction of sample volume and low cost. Moreover, this method enabled the detection of HbA1c % in human whole blood without any pre-treatment, suggesting great promise of this platform for the diagnosis of diabetes. Nature Publishing Group UK 2017-04-21 /pmc/articles/PMC5430690/ /pubmed/28432344 http://dx.doi.org/10.1038/s41598-017-01226-0 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Eissa, Shimaa
Zourob, Mohammed
Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title_full Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title_fullStr Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title_full_unstemmed Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title_short Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
title_sort aptamer- based label-free electrochemical biosensor array for the detection of total and glycated hemoglobin in human whole blood
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5430690/
https://www.ncbi.nlm.nih.gov/pubmed/28432344
http://dx.doi.org/10.1038/s41598-017-01226-0
work_keys_str_mv AT eissashimaa aptamerbasedlabelfreeelectrochemicalbiosensorarrayforthedetectionoftotalandglycatedhemoglobininhumanwholeblood
AT zourobmohammed aptamerbasedlabelfreeelectrochemicalbiosensorarrayforthedetectionoftotalandglycatedhemoglobininhumanwholeblood