Cargando…
Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood
The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we re...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5430690/ https://www.ncbi.nlm.nih.gov/pubmed/28432344 http://dx.doi.org/10.1038/s41598-017-01226-0 |
_version_ | 1783236271737405440 |
---|---|
author | Eissa, Shimaa Zourob, Mohammed |
author_facet | Eissa, Shimaa Zourob, Mohammed |
author_sort | Eissa, Shimaa |
collection | PubMed |
description | The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we report the selection, identification and characterization of specific DNA aptamers against HbA1c- and total hemoglobin (tHb) and their integration into an electrochemical array sensing platform. High affinity and specificity aptamers were selected in vitro showing dissociation constants of 2.8 and 2.7 nM for HbA1c and tHb, respectively. Thiol-modified forms of the aptamers were then immobilised on gold nanoparticles (AuNPs)-modified array electrodes and used for the label-free detection of HbA1c and tHb using square wave voltammetry. The voltammetric aptasensors showed high sensitivity with detection limits of 0.2 and 0.34 ng/ml for HbA1c and tHb, respectively. This array platform is superior to the currently available immunoassays in terms of simplicity, stability, ease of use, reduction of sample volume and low cost. Moreover, this method enabled the detection of HbA1c % in human whole blood without any pre-treatment, suggesting great promise of this platform for the diagnosis of diabetes. |
format | Online Article Text |
id | pubmed-5430690 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-54306902017-05-16 Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood Eissa, Shimaa Zourob, Mohammed Sci Rep Article The increase of the level of glucose in blood leads to an increase in the fraction of glycated hemoglobin (HbA1c). Therefore, the percentage of HbA1c in the blood can serve as a marker for the average glucose level over the past three months and thus, it can be used to diagnose diabetes. Here, we report the selection, identification and characterization of specific DNA aptamers against HbA1c- and total hemoglobin (tHb) and their integration into an electrochemical array sensing platform. High affinity and specificity aptamers were selected in vitro showing dissociation constants of 2.8 and 2.7 nM for HbA1c and tHb, respectively. Thiol-modified forms of the aptamers were then immobilised on gold nanoparticles (AuNPs)-modified array electrodes and used for the label-free detection of HbA1c and tHb using square wave voltammetry. The voltammetric aptasensors showed high sensitivity with detection limits of 0.2 and 0.34 ng/ml for HbA1c and tHb, respectively. This array platform is superior to the currently available immunoassays in terms of simplicity, stability, ease of use, reduction of sample volume and low cost. Moreover, this method enabled the detection of HbA1c % in human whole blood without any pre-treatment, suggesting great promise of this platform for the diagnosis of diabetes. Nature Publishing Group UK 2017-04-21 /pmc/articles/PMC5430690/ /pubmed/28432344 http://dx.doi.org/10.1038/s41598-017-01226-0 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Eissa, Shimaa Zourob, Mohammed Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title | Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title_full | Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title_fullStr | Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title_full_unstemmed | Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title_short | Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood |
title_sort | aptamer- based label-free electrochemical biosensor array for the detection of total and glycated hemoglobin in human whole blood |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5430690/ https://www.ncbi.nlm.nih.gov/pubmed/28432344 http://dx.doi.org/10.1038/s41598-017-01226-0 |
work_keys_str_mv | AT eissashimaa aptamerbasedlabelfreeelectrochemicalbiosensorarrayforthedetectionoftotalandglycatedhemoglobininhumanwholeblood AT zourobmohammed aptamerbasedlabelfreeelectrochemicalbiosensorarrayforthedetectionoftotalandglycatedhemoglobininhumanwholeblood |