Cargando…
Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second
Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for cl...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5431181/ https://www.ncbi.nlm.nih.gov/pubmed/28469205 http://dx.doi.org/10.1038/s41598-017-01649-9 |
_version_ | 1783236383482052608 |
---|---|
author | Hui, Jie Cao, Yingchun Zhang, Yi Kole, Ayeeshik Wang, Pu Yu, Guangli Eakins, Gregory Sturek, Michael Chen, Weibiao Cheng, Ji-Xin |
author_facet | Hui, Jie Cao, Yingchun Zhang, Yi Kole, Ayeeshik Wang, Pu Yu, Guangli Eakins, Gregory Sturek, Michael Chen, Weibiao Cheng, Ji-Xin |
author_sort | Hui, Jie |
collection | PubMed |
description | Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications. |
format | Online Article Text |
id | pubmed-5431181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-54311812017-05-16 Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second Hui, Jie Cao, Yingchun Zhang, Yi Kole, Ayeeshik Wang, Pu Yu, Guangli Eakins, Gregory Sturek, Michael Chen, Weibiao Cheng, Ji-Xin Sci Rep Article Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications. Nature Publishing Group UK 2017-05-03 /pmc/articles/PMC5431181/ /pubmed/28469205 http://dx.doi.org/10.1038/s41598-017-01649-9 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Hui, Jie Cao, Yingchun Zhang, Yi Kole, Ayeeshik Wang, Pu Yu, Guangli Eakins, Gregory Sturek, Michael Chen, Weibiao Cheng, Ji-Xin Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title | Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_full | Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_fullStr | Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_full_unstemmed | Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_short | Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
title_sort | real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5431181/ https://www.ncbi.nlm.nih.gov/pubmed/28469205 http://dx.doi.org/10.1038/s41598-017-01649-9 |
work_keys_str_mv | AT huijie realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT caoyingchun realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT zhangyi realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT koleayeeshik realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT wangpu realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT yuguangli realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT eakinsgregory realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT sturekmichael realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT chenweibiao realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond AT chengjixin realtimeintravascularphotoacousticultrasoundimagingoflipidladenplaqueinhumancoronaryarteryat16framespersecond |