Cargando…

Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture

BACKGROUND: Limb length discrepancy is one of the most common complications after hip arthroplasty. We developed a device - intraoperative limb-length measurement and osteotomy device (ILMOD), and applied it to patients who were treated with hemiarthroplasty for femoral neck fracture to improve limb...

Descripción completa

Detalles Bibliográficos
Autores principales: Zheng, Zhanle, Yang, Lei, Su, Yanling, Yu, Xian, Hou, Zhiyong, Zhang, Yingze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433027/
https://www.ncbi.nlm.nih.gov/pubmed/28506314
http://dx.doi.org/10.1186/s12893-017-0256-4
_version_ 1783236762494042112
author Zheng, Zhanle
Yang, Lei
Su, Yanling
Yu, Xian
Hou, Zhiyong
Zhang, Yingze
author_facet Zheng, Zhanle
Yang, Lei
Su, Yanling
Yu, Xian
Hou, Zhiyong
Zhang, Yingze
author_sort Zheng, Zhanle
collection PubMed
description BACKGROUND: Limb length discrepancy is one of the most common complications after hip arthroplasty. We developed a device - intraoperative limb-length measurement and osteotomy device (ILMOD), and applied it to patients who were treated with hemiarthroplasty for femoral neck fracture to improve limb length discrepancy by providing an accurate osteotomy during hemi-arthroplasty. METHODS: Between April 2012 and October 2013, 65 patients were treated with hip hemiarthroplasty for femoral neck fracture at our trauma center. 31 patients met the inclusion criteria and were randomly enrolled into two groups ILMOD group and control group. Hemiarthroplasty in this study was performed with cement fixation. Treatment-related measurements such as the operation time, attempts of osteotomy, and the volume of intra-operative blood loss were collected. In both groups, postoperative (1 month) radiologic analysis on anteroposterior weight-bearing pelvic view was performed to evaluate limb length discrepancy. RESULTS: The results showed significant improvement in limb length discrepancy in ILMOD group, and analysis of postoperative radiographs found the mean length difference is 2.1 ± 1.9 mm in ILMOD group compared to 8.8 ± 5.1 mm in control group (P < 0.0001). No complications associated with the use of the device were reported, and none of the patients complained of the discomfort related to limb-length discrepancy after surgery. The average intra-operative time was significantly longer in ILMOD group (84.9 ± 9.2 min) compared to that in control group (70.9 ± 10.2 min) (P = 0.0004). CONCLUSIONS: The ILMOD is an effective device that can be used easily for intraoperative limb length measurement and osteotomy during hemiarthroplasty. This method is applicable with Kocher-Langenbeck approach, and the technique could also be used in total hip arthroplasty. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-OOC-15005904. Registered 30 Junuary 2015.
format Online
Article
Text
id pubmed-5433027
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54330272017-05-17 Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture Zheng, Zhanle Yang, Lei Su, Yanling Yu, Xian Hou, Zhiyong Zhang, Yingze BMC Surg Technical Advance BACKGROUND: Limb length discrepancy is one of the most common complications after hip arthroplasty. We developed a device - intraoperative limb-length measurement and osteotomy device (ILMOD), and applied it to patients who were treated with hemiarthroplasty for femoral neck fracture to improve limb length discrepancy by providing an accurate osteotomy during hemi-arthroplasty. METHODS: Between April 2012 and October 2013, 65 patients were treated with hip hemiarthroplasty for femoral neck fracture at our trauma center. 31 patients met the inclusion criteria and were randomly enrolled into two groups ILMOD group and control group. Hemiarthroplasty in this study was performed with cement fixation. Treatment-related measurements such as the operation time, attempts of osteotomy, and the volume of intra-operative blood loss were collected. In both groups, postoperative (1 month) radiologic analysis on anteroposterior weight-bearing pelvic view was performed to evaluate limb length discrepancy. RESULTS: The results showed significant improvement in limb length discrepancy in ILMOD group, and analysis of postoperative radiographs found the mean length difference is 2.1 ± 1.9 mm in ILMOD group compared to 8.8 ± 5.1 mm in control group (P < 0.0001). No complications associated with the use of the device were reported, and none of the patients complained of the discomfort related to limb-length discrepancy after surgery. The average intra-operative time was significantly longer in ILMOD group (84.9 ± 9.2 min) compared to that in control group (70.9 ± 10.2 min) (P = 0.0004). CONCLUSIONS: The ILMOD is an effective device that can be used easily for intraoperative limb length measurement and osteotomy during hemiarthroplasty. This method is applicable with Kocher-Langenbeck approach, and the technique could also be used in total hip arthroplasty. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-OOC-15005904. Registered 30 Junuary 2015. BioMed Central 2017-05-15 /pmc/articles/PMC5433027/ /pubmed/28506314 http://dx.doi.org/10.1186/s12893-017-0256-4 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Technical Advance
Zheng, Zhanle
Yang, Lei
Su, Yanling
Yu, Xian
Hou, Zhiyong
Zhang, Yingze
Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title_full Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title_fullStr Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title_full_unstemmed Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title_short Application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
title_sort application of intraoperative limb-length measurement by a new osteotomy device in hemiarthroplasty for treating femoral neck fracture
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433027/
https://www.ncbi.nlm.nih.gov/pubmed/28506314
http://dx.doi.org/10.1186/s12893-017-0256-4
work_keys_str_mv AT zhengzhanle applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture
AT yanglei applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture
AT suyanling applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture
AT yuxian applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture
AT houzhiyong applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture
AT zhangyingze applicationofintraoperativelimblengthmeasurementbyanewosteotomydeviceinhemiarthroplastyfortreatingfemoralneckfracture