Cargando…

In vitro analysis of the segmental flexibility of the thoracic spine

Basic knowledge about the thoracic spinal flexibility is limited and to the authors’ knowledge, no in vitro studies have examined the flexibility of every thoracic spinal segment under standardized experimental conditions using pure moments. In our in vitro study, 68 human thoracic functional spinal...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilke, Hans-Joachim, Herkommer, Andrea, Werner, Karin, Liebsch, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433776/
https://www.ncbi.nlm.nih.gov/pubmed/28520819
http://dx.doi.org/10.1371/journal.pone.0177823
_version_ 1783236920466210816
author Wilke, Hans-Joachim
Herkommer, Andrea
Werner, Karin
Liebsch, Christian
author_facet Wilke, Hans-Joachim
Herkommer, Andrea
Werner, Karin
Liebsch, Christian
author_sort Wilke, Hans-Joachim
collection PubMed
description Basic knowledge about the thoracic spinal flexibility is limited and to the authors’ knowledge, no in vitro studies have examined the flexibility of every thoracic spinal segment under standardized experimental conditions using pure moments. In our in vitro study, 68 human thoracic functional spinal units including the costovertebral joints (at least n = 6 functional spinal units per segment from T1-T2 to T11-T12) were loaded with pure moments of ±7.5 Nm in flexion/extension, lateral bending, and axial rotation in a custom-built spine tester to analyze range of motion (ROM) and neutral zone (NZ). ROM and NZ showed symmetric motion behavior in all loading planes. In each loading direction, the segment T1-T2 exhibited the highest ROM. In flexion/extension, the whole thoracic region, with exception of T1-T2 (14°), had an average ROM between 6° and 8°. In lateral bending, the upper thoracic region (T1-T7) was, with an average ROM between 10° and 12°, more flexible than the lower thoracic region (T7-T12) with an average ROM between 8° and 9°. In axial rotation, the thoracic region offered the highest overall flexibility with an average ROM between 10° and 12° in the upper and middle thoracic spine (T1-T10) and between 7° and 8° in the lower thoracic spine (T10-T12), while a trend of continuous decrease of ROM could be observed in the lower thoracic region (T7-T12). Comparing these ROM values with those in literature, they agree that ROM is lowest in flexion/extension and highest in axial rotation, as well as decreasing in the lower segments in axial rotation. Differences were found in flexion/extension and lateral bending in the lower segments, where, in contrast to the literature, no increase of the ROM from superior to inferior segments was found. The data of this in vitro study could be used for the validation of numerical models and the design of further in vitro studies of the thoracic spine without the rib cage, the verification of animal models, as well as the interpretation of already published human in vitro data.
format Online
Article
Text
id pubmed-5433776
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54337762017-05-26 In vitro analysis of the segmental flexibility of the thoracic spine Wilke, Hans-Joachim Herkommer, Andrea Werner, Karin Liebsch, Christian PLoS One Research Article Basic knowledge about the thoracic spinal flexibility is limited and to the authors’ knowledge, no in vitro studies have examined the flexibility of every thoracic spinal segment under standardized experimental conditions using pure moments. In our in vitro study, 68 human thoracic functional spinal units including the costovertebral joints (at least n = 6 functional spinal units per segment from T1-T2 to T11-T12) were loaded with pure moments of ±7.5 Nm in flexion/extension, lateral bending, and axial rotation in a custom-built spine tester to analyze range of motion (ROM) and neutral zone (NZ). ROM and NZ showed symmetric motion behavior in all loading planes. In each loading direction, the segment T1-T2 exhibited the highest ROM. In flexion/extension, the whole thoracic region, with exception of T1-T2 (14°), had an average ROM between 6° and 8°. In lateral bending, the upper thoracic region (T1-T7) was, with an average ROM between 10° and 12°, more flexible than the lower thoracic region (T7-T12) with an average ROM between 8° and 9°. In axial rotation, the thoracic region offered the highest overall flexibility with an average ROM between 10° and 12° in the upper and middle thoracic spine (T1-T10) and between 7° and 8° in the lower thoracic spine (T10-T12), while a trend of continuous decrease of ROM could be observed in the lower thoracic region (T7-T12). Comparing these ROM values with those in literature, they agree that ROM is lowest in flexion/extension and highest in axial rotation, as well as decreasing in the lower segments in axial rotation. Differences were found in flexion/extension and lateral bending in the lower segments, where, in contrast to the literature, no increase of the ROM from superior to inferior segments was found. The data of this in vitro study could be used for the validation of numerical models and the design of further in vitro studies of the thoracic spine without the rib cage, the verification of animal models, as well as the interpretation of already published human in vitro data. Public Library of Science 2017-05-16 /pmc/articles/PMC5433776/ /pubmed/28520819 http://dx.doi.org/10.1371/journal.pone.0177823 Text en © 2017 Wilke et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Wilke, Hans-Joachim
Herkommer, Andrea
Werner, Karin
Liebsch, Christian
In vitro analysis of the segmental flexibility of the thoracic spine
title In vitro analysis of the segmental flexibility of the thoracic spine
title_full In vitro analysis of the segmental flexibility of the thoracic spine
title_fullStr In vitro analysis of the segmental flexibility of the thoracic spine
title_full_unstemmed In vitro analysis of the segmental flexibility of the thoracic spine
title_short In vitro analysis of the segmental flexibility of the thoracic spine
title_sort in vitro analysis of the segmental flexibility of the thoracic spine
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5433776/
https://www.ncbi.nlm.nih.gov/pubmed/28520819
http://dx.doi.org/10.1371/journal.pone.0177823
work_keys_str_mv AT wilkehansjoachim invitroanalysisofthesegmentalflexibilityofthethoracicspine
AT herkommerandrea invitroanalysisofthesegmentalflexibilityofthethoracicspine
AT wernerkarin invitroanalysisofthesegmentalflexibilityofthethoracicspine
AT liebschchristian invitroanalysisofthesegmentalflexibilityofthethoracicspine