High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern

BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reac...

Descripción completa

Detalles Bibliográficos
Autores principales: Laitinen, Minna, Nieminen, Jyrki, Reito, Aleksi, Pakarinen, Toni-Karri, Suomalainen, Piia, Pamilo, Konsta, Parkkinen, Jyrki, Lont, Tonis, Eskelinen, Antti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434594/
https://www.ncbi.nlm.nih.gov/pubmed/28122467
http://dx.doi.org/10.1080/17453674.2017.1283846
_version_ 1783237078760292352
author Laitinen, Minna
Nieminen, Jyrki
Reito, Aleksi
Pakarinen, Toni-Karri
Suomalainen, Piia
Pamilo, Konsta
Parkkinen, Jyrki
Lont, Tonis
Eskelinen, Antti
author_facet Laitinen, Minna
Nieminen, Jyrki
Reito, Aleksi
Pakarinen, Toni-Karri
Suomalainen, Piia
Pamilo, Konsta
Parkkinen, Jyrki
Lont, Tonis
Eskelinen, Antti
author_sort Laitinen, Minna
collection PubMed
description BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). PATIENTS AND METHODS: 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. RESULTS: The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. INTERPRETATION: Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA.
format Online
Article
Text
id pubmed-5434594
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-54345942017-06-01 High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern Laitinen, Minna Nieminen, Jyrki Reito, Aleksi Pakarinen, Toni-Karri Suomalainen, Piia Pamilo, Konsta Parkkinen, Jyrki Lont, Tonis Eskelinen, Antti Acta Orthop Knee BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). PATIENTS AND METHODS: 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. RESULTS: The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. INTERPRETATION: Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA. Taylor & Francis 2017-06 2017-01-26 /pmc/articles/PMC5434594/ /pubmed/28122467 http://dx.doi.org/10.1080/17453674.2017.1283846 Text en © 2017 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0)
spellingShingle Knee
Laitinen, Minna
Nieminen, Jyrki
Reito, Aleksi
Pakarinen, Toni-Karri
Suomalainen, Piia
Pamilo, Konsta
Parkkinen, Jyrki
Lont, Tonis
Eskelinen, Antti
High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title_full High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title_fullStr High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title_full_unstemmed High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title_short High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
title_sort high blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: a cause for concern
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434594/
https://www.ncbi.nlm.nih.gov/pubmed/28122467
http://dx.doi.org/10.1080/17453674.2017.1283846
work_keys_str_mv AT laitinenminna highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT nieminenjyrki highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT reitoaleksi highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT pakarinentonikarri highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT suomalainenpiia highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT pamilokonsta highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT parkkinenjyrki highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT lonttonis highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern
AT eskelinenantti highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern