High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern
BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reac...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434594/ https://www.ncbi.nlm.nih.gov/pubmed/28122467 http://dx.doi.org/10.1080/17453674.2017.1283846 |
_version_ | 1783237078760292352 |
---|---|
author | Laitinen, Minna Nieminen, Jyrki Reito, Aleksi Pakarinen, Toni-Karri Suomalainen, Piia Pamilo, Konsta Parkkinen, Jyrki Lont, Tonis Eskelinen, Antti |
author_facet | Laitinen, Minna Nieminen, Jyrki Reito, Aleksi Pakarinen, Toni-Karri Suomalainen, Piia Pamilo, Konsta Parkkinen, Jyrki Lont, Tonis Eskelinen, Antti |
author_sort | Laitinen, Minna |
collection | PubMed |
description | BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). PATIENTS AND METHODS: 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. RESULTS: The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. INTERPRETATION: Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA. |
format | Online Article Text |
id | pubmed-5434594 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-54345942017-06-01 High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern Laitinen, Minna Nieminen, Jyrki Reito, Aleksi Pakarinen, Toni-Karri Suomalainen, Piia Pamilo, Konsta Parkkinen, Jyrki Lont, Tonis Eskelinen, Antti Acta Orthop Knee BACKGROUND AND PURPOSE: There has been increasing alarm regarding metal-on-metal (MoM) joint replacements leading to elevated levels of metal ions and adverse reactions to metal debris (ARMDs). There is little information available concerning the prevalence of and risk factors for these adverse reactions, except with MoM hip joint replacements. We determined the levels of metal ions in blood and the rate of revision due to ARMDs in patients treated with MoM hinge total knee arthroplasty (TKA). PATIENTS AND METHODS: 22 patients with TKAs and MoM hinge connecting mechanisms were studied for whole-blood chromium and cobalt levels at 6 months, 1 year, and/or ≥2 years after surgery. Possible ARMDs were investigated by MRI. 12 patients with TKAs and metal-on-polyethylene (MoP) connecting mechanisms served as controls. RESULTS: The cobalt levels were over 5 ppb in 19 of the 22 patients in the MoM group and in 1 of the 12 patients in the MoP group. The chromium levels were over 5 ppb in 11 of the 22 patients in the MoM group and in none of the 12 patients in the MoP group. Pseudotumors were operated in 4 of the 22 patients in the MoM group and in none of the patients in the MoP group. INTERPRETATION: Our results clearly show that the MoM hinge TKA carries a high risk of increased levels of systemic metal ions and also local ARMD, leading to complicated knee revisions. We therefore discourage the use of MoM hinge TKA. Taylor & Francis 2017-06 2017-01-26 /pmc/articles/PMC5434594/ /pubmed/28122467 http://dx.doi.org/10.1080/17453674.2017.1283846 Text en © 2017 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) |
spellingShingle | Knee Laitinen, Minna Nieminen, Jyrki Reito, Aleksi Pakarinen, Toni-Karri Suomalainen, Piia Pamilo, Konsta Parkkinen, Jyrki Lont, Tonis Eskelinen, Antti High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title | High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title_full | High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title_fullStr | High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title_full_unstemmed | High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title_short | High blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: A cause for concern |
title_sort | high blood metal ion levels in 19 of 22 patients with metal-on-metal hinge knee replacements: a cause for concern |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434594/ https://www.ncbi.nlm.nih.gov/pubmed/28122467 http://dx.doi.org/10.1080/17453674.2017.1283846 |
work_keys_str_mv | AT laitinenminna highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT nieminenjyrki highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT reitoaleksi highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT pakarinentonikarri highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT suomalainenpiia highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT pamilokonsta highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT parkkinenjyrki highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT lonttonis highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern AT eskelinenantti highbloodmetalionlevelsin19of22patientswithmetalonmetalhingekneereplacementsacauseforconcern |