Cargando…
Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years
BACKGROUND AND PURPOSE: Maximal total point motion (MTPM) measured by radiostereometry (RSA) is widely used as a predictor of total knee arthroplasty (TKA) loosening. We compared the ability of different RSA measurements at different time points to predict loosening of tibial TKA components in the l...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434596/ https://www.ncbi.nlm.nih.gov/pubmed/28266241 http://dx.doi.org/10.1080/17453674.2017.1297001 |
_version_ | 1783237079262560256 |
---|---|
author | Gudnason, Asgeir Adalberth, Gunnar Nilsson, Kjell-Gunnar Hailer, Nils P |
author_facet | Gudnason, Asgeir Adalberth, Gunnar Nilsson, Kjell-Gunnar Hailer, Nils P |
author_sort | Gudnason, Asgeir |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Maximal total point motion (MTPM) measured by radiostereometry (RSA) is widely used as a predictor of total knee arthroplasty (TKA) loosening. We compared the ability of different RSA measurements at different time points to predict loosening of tibial TKA components in the long term. PATIENTS AND METHODS: 116 TKAs in 116 patients were included in our analysis. 16 (14.8–17.4) years after surgery, 5 tibial components had been revised due to aseptic loosening. Receiver operating characteristic curves were calculated in order to investigate the specificity and sensitivity of different RSA parameters at different thresholds. RESULTS: Rotation around the transverse (x-) axis measured 2 years postoperatively had the best predictive value of all parameters, with an area under the curve (AUC) of 80%. Using a threshold of 0.8 degrees, a specificity of 85% and a sensitivity of 50% were reached. The AUC for tibial component distal translation was 79% and it was 77% for proximal translation, whereas it was only 68% for MTPM. INTERPRETATION: Rotation of the cemented tibial component around the transverse axis, proximal translation, and distal translation are slightly better at predicting aseptic loosening than MTPM, and tibial component migration measured after 2 years gives a good prediction of aseptic loosening up to 15 years. |
format | Online Article Text |
id | pubmed-5434596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-54345962017-06-01 Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years Gudnason, Asgeir Adalberth, Gunnar Nilsson, Kjell-Gunnar Hailer, Nils P Acta Orthop Knee BACKGROUND AND PURPOSE: Maximal total point motion (MTPM) measured by radiostereometry (RSA) is widely used as a predictor of total knee arthroplasty (TKA) loosening. We compared the ability of different RSA measurements at different time points to predict loosening of tibial TKA components in the long term. PATIENTS AND METHODS: 116 TKAs in 116 patients were included in our analysis. 16 (14.8–17.4) years after surgery, 5 tibial components had been revised due to aseptic loosening. Receiver operating characteristic curves were calculated in order to investigate the specificity and sensitivity of different RSA parameters at different thresholds. RESULTS: Rotation around the transverse (x-) axis measured 2 years postoperatively had the best predictive value of all parameters, with an area under the curve (AUC) of 80%. Using a threshold of 0.8 degrees, a specificity of 85% and a sensitivity of 50% were reached. The AUC for tibial component distal translation was 79% and it was 77% for proximal translation, whereas it was only 68% for MTPM. INTERPRETATION: Rotation of the cemented tibial component around the transverse axis, proximal translation, and distal translation are slightly better at predicting aseptic loosening than MTPM, and tibial component migration measured after 2 years gives a good prediction of aseptic loosening up to 15 years. Taylor & Francis 2017-06 2017-03-07 /pmc/articles/PMC5434596/ /pubmed/28266241 http://dx.doi.org/10.1080/17453674.2017.1297001 Text en © 2017 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0) |
spellingShingle | Knee Gudnason, Asgeir Adalberth, Gunnar Nilsson, Kjell-Gunnar Hailer, Nils P Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title | Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title_full | Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title_fullStr | Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title_full_unstemmed | Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title_short | Tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: A follow-up of 116 total knee arthroplasties after at least 15 years |
title_sort | tibial component rotation around the transverse axis measured by radiostereometry predicts aseptic loosening better than maximal total point motion: a follow-up of 116 total knee arthroplasties after at least 15 years |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434596/ https://www.ncbi.nlm.nih.gov/pubmed/28266241 http://dx.doi.org/10.1080/17453674.2017.1297001 |
work_keys_str_mv | AT gudnasonasgeir tibialcomponentrotationaroundthetransverseaxismeasuredbyradiostereometrypredictsasepticlooseningbetterthanmaximaltotalpointmotionafollowupof116totalkneearthroplastiesafteratleast15years AT adalberthgunnar tibialcomponentrotationaroundthetransverseaxismeasuredbyradiostereometrypredictsasepticlooseningbetterthanmaximaltotalpointmotionafollowupof116totalkneearthroplastiesafteratleast15years AT nilssonkjellgunnar tibialcomponentrotationaroundthetransverseaxismeasuredbyradiostereometrypredictsasepticlooseningbetterthanmaximaltotalpointmotionafollowupof116totalkneearthroplastiesafteratleast15years AT hailernilsp tibialcomponentrotationaroundthetransverseaxismeasuredbyradiostereometrypredictsasepticlooseningbetterthanmaximaltotalpointmotionafollowupof116totalkneearthroplastiesafteratleast15years |