Cargando…

The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies

BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation...

Descripción completa

Detalles Bibliográficos
Autores principales: Ten Brinke, Bart, Beumer, Annechien, Koenraadt, Koen L M, Eygendaal, Denise, Kraan, Gerald A, Mathijssen, Nina M C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434603/
https://www.ncbi.nlm.nih.gov/pubmed/28464752
http://dx.doi.org/10.1080/17453674.2017.1291872
_version_ 1783237080970690560
author Ten Brinke, Bart
Beumer, Annechien
Koenraadt, Koen L M
Eygendaal, Denise
Kraan, Gerald A
Mathijssen, Nina M C
author_facet Ten Brinke, Bart
Beumer, Annechien
Koenraadt, Koen L M
Eygendaal, Denise
Kraan, Gerald A
Mathijssen, Nina M C
author_sort Ten Brinke, Bart
collection PubMed
description BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. PATIENTS AND METHODS: PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA RESULTS: 23 studies were included. Precision values were in the 0.06–0.88 mm and 0.05–10.7° range for the shoulder, the 0.05–0.34 mm and 0.16–0.76° range for the elbow, and the 0.16–1.83 mm and 11–124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. INTERPRETATION: RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.
format Online
Article
Text
id pubmed-5434603
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-54346032017-06-01 The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies Ten Brinke, Bart Beumer, Annechien Koenraadt, Koen L M Eygendaal, Denise Kraan, Gerald A Mathijssen, Nina M C Acta Orthop Upper Limb BACKGROUND AND PURPOSE: Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. PATIENTS AND METHODS: PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA RESULTS: 23 studies were included. Precision values were in the 0.06–0.88 mm and 0.05–10.7° range for the shoulder, the 0.05–0.34 mm and 0.16–0.76° range for the elbow, and the 0.16–1.83 mm and 11–124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. INTERPRETATION: RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies. Taylor & Francis 2017-06 2017-03-02 /pmc/articles/PMC5434603/ /pubmed/28464752 http://dx.doi.org/10.1080/17453674.2017.1291872 Text en © 2017 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0)
spellingShingle Upper Limb
Ten Brinke, Bart
Beumer, Annechien
Koenraadt, Koen L M
Eygendaal, Denise
Kraan, Gerald A
Mathijssen, Nina M C
The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title_full The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title_fullStr The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title_full_unstemmed The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title_short The accuracy and precision of radiostereometric analysis in upper limb arthroplasty: A systematic review of 23 RSA studies
title_sort accuracy and precision of radiostereometric analysis in upper limb arthroplasty: a systematic review of 23 rsa studies
topic Upper Limb
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434603/
https://www.ncbi.nlm.nih.gov/pubmed/28464752
http://dx.doi.org/10.1080/17453674.2017.1291872
work_keys_str_mv AT tenbrinkebart theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT beumerannechien theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT koenraadtkoenlm theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT eygendaaldenise theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT kraangeralda theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT mathijssenninamc theaccuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT tenbrinkebart accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT beumerannechien accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT koenraadtkoenlm accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT eygendaaldenise accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT kraangeralda accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies
AT mathijssenninamc accuracyandprecisionofradiostereometricanalysisinupperlimbarthroplastyasystematicreviewof23rsastudies