Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale
Power input is an important engineering and scale‐up/down criterion in stirred bioreactors. However, reliably measuring power input in laboratory‐scale systems is still challenging. Even though torque measurements have proven to be suitable in pilot scale systems, sensor accuracy, resolution, and er...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434943/ https://www.ncbi.nlm.nih.gov/pubmed/28579937 http://dx.doi.org/10.1002/elsc.201600096 |
_version_ | 1783237147090747392 |
---|---|
author | Kaiser, Stephan C. Werner, Sören Jossen, Valentin Kraume, Matthias Eibl, Dieter |
author_facet | Kaiser, Stephan C. Werner, Sören Jossen, Valentin Kraume, Matthias Eibl, Dieter |
author_sort | Kaiser, Stephan C. |
collection | PubMed |
description | Power input is an important engineering and scale‐up/down criterion in stirred bioreactors. However, reliably measuring power input in laboratory‐scale systems is still challenging. Even though torque measurements have proven to be suitable in pilot scale systems, sensor accuracy, resolution, and errors from relatively high levels of friction inside bearings can become limiting factors at smaller scales. An experimental setup for power input measurements was developed in this study by focusing on stainless steel and single‐use bioreactors in the single‐digit volume range. The friction losses inside the air bearings were effectively reduced to less than 0.5% of the measurement range of the torque meter. A comparison of dimensionless power numbers determined for a reference Rushton turbine stirrer (N (P) = 4.17 ± 0.14 for fully turbulent conditions) revealed good agreement with literature data. Hence, the power numbers of several reusable and single‐use bioreactors could be determined over a wide range of Reynolds numbers between 100 and >10(4). Power numbers of between 0.3 and 4.5 (for Re = 10(4)) were determined for the different systems. The rigid plastic vessels showed similar power characteristics to their reusable counterparts. Thus, it was demonstrated that the torque‐based technique can be used to reliably measure power input in stirred reusable and single‐use bioreactors at the laboratory scale. |
format | Online Article Text |
id | pubmed-5434943 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-54349432017-06-01 Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale Kaiser, Stephan C. Werner, Sören Jossen, Valentin Kraume, Matthias Eibl, Dieter Eng Life Sci Research Articles Power input is an important engineering and scale‐up/down criterion in stirred bioreactors. However, reliably measuring power input in laboratory‐scale systems is still challenging. Even though torque measurements have proven to be suitable in pilot scale systems, sensor accuracy, resolution, and errors from relatively high levels of friction inside bearings can become limiting factors at smaller scales. An experimental setup for power input measurements was developed in this study by focusing on stainless steel and single‐use bioreactors in the single‐digit volume range. The friction losses inside the air bearings were effectively reduced to less than 0.5% of the measurement range of the torque meter. A comparison of dimensionless power numbers determined for a reference Rushton turbine stirrer (N (P) = 4.17 ± 0.14 for fully turbulent conditions) revealed good agreement with literature data. Hence, the power numbers of several reusable and single‐use bioreactors could be determined over a wide range of Reynolds numbers between 100 and >10(4). Power numbers of between 0.3 and 4.5 (for Re = 10(4)) were determined for the different systems. The rigid plastic vessels showed similar power characteristics to their reusable counterparts. Thus, it was demonstrated that the torque‐based technique can be used to reliably measure power input in stirred reusable and single‐use bioreactors at the laboratory scale. John Wiley and Sons Inc. 2016-11-25 /pmc/articles/PMC5434943/ /pubmed/28579937 http://dx.doi.org/10.1002/elsc.201600096 Text en © 2016 The Authors. Engineering in Life Sciences Published by Wiley‐VCH Verlag GmbH & Co. KGaA, Weinheim This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Research Articles Kaiser, Stephan C. Werner, Sören Jossen, Valentin Kraume, Matthias Eibl, Dieter Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title | Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title_full | Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title_fullStr | Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title_full_unstemmed | Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title_short | Development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
title_sort | development of a method for reliable power input measurements in conventional and single‐use stirred bioreactors at laboratory scale |
topic | Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5434943/ https://www.ncbi.nlm.nih.gov/pubmed/28579937 http://dx.doi.org/10.1002/elsc.201600096 |
work_keys_str_mv | AT kaiserstephanc developmentofamethodforreliablepowerinputmeasurementsinconventionalandsingleusestirredbioreactorsatlaboratoryscale AT wernersoren developmentofamethodforreliablepowerinputmeasurementsinconventionalandsingleusestirredbioreactorsatlaboratoryscale AT jossenvalentin developmentofamethodforreliablepowerinputmeasurementsinconventionalandsingleusestirredbioreactorsatlaboratoryscale AT kraumematthias developmentofamethodforreliablepowerinputmeasurementsinconventionalandsingleusestirredbioreactorsatlaboratoryscale AT eibldieter developmentofamethodforreliablepowerinputmeasurementsinconventionalandsingleusestirredbioreactorsatlaboratoryscale |