Cargando…
Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye
AIMS: Cryoballoon pulmonary vein (PV) isolation in patients with atrial fibrillation has proven to be effective in short-term and long-term follow-up. To visualise the PV anatomy, pre-ablation contrast pulmonary venography is commonly performed. Three-dimensional (3D) computed tomography (CT) overla...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bohn Stafleu van Loghum
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5435618/ https://www.ncbi.nlm.nih.gov/pubmed/28205119 http://dx.doi.org/10.1007/s12471-017-0962-7 |
_version_ | 1783237243036499968 |
---|---|
author | Oude Velthuis, B. Molenaar, M. Reinhart Dorman, H. G. Stevenhagen, J. Y. Scholten, M. F. van der Palen, J. van Opstal, J. M. |
author_facet | Oude Velthuis, B. Molenaar, M. Reinhart Dorman, H. G. Stevenhagen, J. Y. Scholten, M. F. van der Palen, J. van Opstal, J. M. |
author_sort | Oude Velthuis, B. |
collection | PubMed |
description | AIMS: Cryoballoon pulmonary vein (PV) isolation in patients with atrial fibrillation has proven to be effective in short-term and long-term follow-up. To visualise the PV anatomy, pre-ablation contrast pulmonary venography is commonly performed. Three-dimensional (3D) computed tomography (CT) overlay is a new technique creating a live 3D image of the left atrium by integrating a previously obtained CT scan during fluoroscopy. To evaluate the benefits of 3D CT overlay during cryoballoon ablation, we studied the use of 3D CT overlay versus contrast pulmonary venography in a randomised fashion in patients with paroxysmal atrial fibrillation undergoing cryoballoon PV isolation. METHODS AND RESULTS: Between October 2012 and June 2013, 30 patients accepted for PV isolation were randomised to cryoballoon PV isolation using either 3D CT overlay or contrast pulmonary venography. All patients underwent a pre-procedural cardiac CT for evaluation of the anatomy of the left atrium (LA) and the PVs. In the 3D CT overlay group, a 3D reconstruction of the LA and PVs was made. An overlay of the CT reconstruction was then projected over live fluoroscopy. Patients in the contrast pulmonary venography group received significantly more contrast agent (77.1 ± 21.2 cc vs 40.1 ± 17.6 cc, p < 0.001) and radiation (43.0 ± 21.9 Gy.cm2 vs 28.41 ± 11.7 Gy.cm2, p = 0.04) than subjects in the 3D CT overlay group. There was no difference in total procedure time, fluoroscopy time and the amount of cryoapplications between the two groups. CONCLUSION: The use of 3D CT overlay decreases radiation and contrast dye exposure and can assist in guiding cryoballoon-based PV isolation. |
format | Online Article Text |
id | pubmed-5435618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Bohn Stafleu van Loghum |
record_format | MEDLINE/PubMed |
spelling | pubmed-54356182017-05-31 Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye Oude Velthuis, B. Molenaar, M. Reinhart Dorman, H. G. Stevenhagen, J. Y. Scholten, M. F. van der Palen, J. van Opstal, J. M. Neth Heart J Original Article AIMS: Cryoballoon pulmonary vein (PV) isolation in patients with atrial fibrillation has proven to be effective in short-term and long-term follow-up. To visualise the PV anatomy, pre-ablation contrast pulmonary venography is commonly performed. Three-dimensional (3D) computed tomography (CT) overlay is a new technique creating a live 3D image of the left atrium by integrating a previously obtained CT scan during fluoroscopy. To evaluate the benefits of 3D CT overlay during cryoballoon ablation, we studied the use of 3D CT overlay versus contrast pulmonary venography in a randomised fashion in patients with paroxysmal atrial fibrillation undergoing cryoballoon PV isolation. METHODS AND RESULTS: Between October 2012 and June 2013, 30 patients accepted for PV isolation were randomised to cryoballoon PV isolation using either 3D CT overlay or contrast pulmonary venography. All patients underwent a pre-procedural cardiac CT for evaluation of the anatomy of the left atrium (LA) and the PVs. In the 3D CT overlay group, a 3D reconstruction of the LA and PVs was made. An overlay of the CT reconstruction was then projected over live fluoroscopy. Patients in the contrast pulmonary venography group received significantly more contrast agent (77.1 ± 21.2 cc vs 40.1 ± 17.6 cc, p < 0.001) and radiation (43.0 ± 21.9 Gy.cm2 vs 28.41 ± 11.7 Gy.cm2, p = 0.04) than subjects in the 3D CT overlay group. There was no difference in total procedure time, fluoroscopy time and the amount of cryoapplications between the two groups. CONCLUSION: The use of 3D CT overlay decreases radiation and contrast dye exposure and can assist in guiding cryoballoon-based PV isolation. Bohn Stafleu van Loghum 2017-02-15 2017-06 /pmc/articles/PMC5435618/ /pubmed/28205119 http://dx.doi.org/10.1007/s12471-017-0962-7 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Article Oude Velthuis, B. Molenaar, M. Reinhart Dorman, H. G. Stevenhagen, J. Y. Scholten, M. F. van der Palen, J. van Opstal, J. M. Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title | Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title_full | Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title_fullStr | Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title_full_unstemmed | Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title_short | Use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
title_sort | use of three-dimensional computed tomography overlay for real-time cryoballoon ablation in atrial fibrillation reduces radiation dose and contrast dye |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5435618/ https://www.ncbi.nlm.nih.gov/pubmed/28205119 http://dx.doi.org/10.1007/s12471-017-0962-7 |
work_keys_str_mv | AT oudevelthuisb useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT molenaarm useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT reinhartdormanhg useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT stevenhagenjy useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT scholtenmf useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT vanderpalenj useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye AT vanopstaljm useofthreedimensionalcomputedtomographyoverlayforrealtimecryoballoonablationinatrialfibrillationreducesradiationdoseandcontrastdye |