Cargando…
Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea
PURPOSE: To assess intra-observer reproducibility and repeatability of corneal pachymetry measurements with RTVue XR-100 anterior segment optical coherence tomography (AS-OCT) in normal cornea. METHODS: Eighty-four eyes of 84 healthy volunteers were enrolled for this study. A single examiner perform...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5436386/ https://www.ncbi.nlm.nih.gov/pubmed/28559715 http://dx.doi.org/10.1016/j.sjopt.2017.04.003 |
_version_ | 1783237393064656896 |
---|---|
author | Mansoori, Tarannum Balakrishna, Nagalla |
author_facet | Mansoori, Tarannum Balakrishna, Nagalla |
author_sort | Mansoori, Tarannum |
collection | PubMed |
description | PURPOSE: To assess intra-observer reproducibility and repeatability of corneal pachymetry measurements with RTVue XR-100 anterior segment optical coherence tomography (AS-OCT) in normal cornea. METHODS: Eighty-four eyes of 84 healthy volunteers were enrolled for this study. A single examiner performed 3 successive corneal pachymetry mappings with RTVue XR-100 AS -OCT in a single session. One eye was randomly selected for the analysis. Intrasession intraexaminer reproducibility and repeatability were calculated for the minimum corneal thickness (MCT), central corneal thickness (CCT, central 0–2 mm), pericentral (2–5 mm) and peripheral (5–6 mm) annular zones of cornea, in the pachymetry mapping protocol by intraclass correlation coefficient (ICC), coefficient of variation and test retest variability. RESULTS: The mean CCT was 497.08 ± 32.83 µm and MCT was 490.28 ± 32.87 µm. ICC was 0.994 for CCT and 0.983 for MCT in central 2 mm zone. ICC in the pericentral 2–5 mm zones and 5–6 mm zone was lower than that in central 2 mm zone, but were still over 0.961 in 2–5 mm zone and had ICC of 0.85 in 5–6 mm zone. CONCLUSION: In normal cornea, corneal thickness measurements produced highly repeatable pachymetry measurements at the central and paracentral zones (up to 6-mm diameter) which could be because of the high resolution and faster image acquisition with RTVue XR-100 OCT. |
format | Online Article Text |
id | pubmed-5436386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-54363862017-05-30 Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea Mansoori, Tarannum Balakrishna, Nagalla Saudi J Ophthalmol Original Article PURPOSE: To assess intra-observer reproducibility and repeatability of corneal pachymetry measurements with RTVue XR-100 anterior segment optical coherence tomography (AS-OCT) in normal cornea. METHODS: Eighty-four eyes of 84 healthy volunteers were enrolled for this study. A single examiner performed 3 successive corneal pachymetry mappings with RTVue XR-100 AS -OCT in a single session. One eye was randomly selected for the analysis. Intrasession intraexaminer reproducibility and repeatability were calculated for the minimum corneal thickness (MCT), central corneal thickness (CCT, central 0–2 mm), pericentral (2–5 mm) and peripheral (5–6 mm) annular zones of cornea, in the pachymetry mapping protocol by intraclass correlation coefficient (ICC), coefficient of variation and test retest variability. RESULTS: The mean CCT was 497.08 ± 32.83 µm and MCT was 490.28 ± 32.87 µm. ICC was 0.994 for CCT and 0.983 for MCT in central 2 mm zone. ICC in the pericentral 2–5 mm zones and 5–6 mm zone was lower than that in central 2 mm zone, but were still over 0.961 in 2–5 mm zone and had ICC of 0.85 in 5–6 mm zone. CONCLUSION: In normal cornea, corneal thickness measurements produced highly repeatable pachymetry measurements at the central and paracentral zones (up to 6-mm diameter) which could be because of the high resolution and faster image acquisition with RTVue XR-100 OCT. Elsevier 2017 2017-04-09 /pmc/articles/PMC5436386/ /pubmed/28559715 http://dx.doi.org/10.1016/j.sjopt.2017.04.003 Text en © 2017 The Authors. Production and hosting by Elsevier B.V. on behalf of Saudi Ophthalmological Society, King Saud University. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Mansoori, Tarannum Balakrishna, Nagalla Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title | Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title_full | Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title_fullStr | Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title_full_unstemmed | Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title_short | Intrasession repeatability of pachymetry measurements with RTVue XR 100 optical coherence tomography in normal cornea |
title_sort | intrasession repeatability of pachymetry measurements with rtvue xr 100 optical coherence tomography in normal cornea |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5436386/ https://www.ncbi.nlm.nih.gov/pubmed/28559715 http://dx.doi.org/10.1016/j.sjopt.2017.04.003 |
work_keys_str_mv | AT mansooritarannum intrasessionrepeatabilityofpachymetrymeasurementswithrtvuexr100opticalcoherencetomographyinnormalcornea AT balakrishnanagalla intrasessionrepeatabilityofpachymetrymeasurementswithrtvuexr100opticalcoherencetomographyinnormalcornea |