Cargando…
Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves
BACKGROUND: Detection of plant diseases in a fast and simple way is crucial for timely disease control. Conventionally, plant diseases are accurately identified by DNA, RNA or serology based methods which are time consuming, complex and expensive. Mid-infrared spectroscopy is a promising technique t...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5436460/ https://www.ncbi.nlm.nih.gov/pubmed/28529536 http://dx.doi.org/10.1186/s13007-017-0190-6 |
_version_ | 1783237410712190976 |
---|---|
author | Zhang, Chu Feng, Xuping Wang, Jian Liu, Fei He, Yong Zhou, Weijun |
author_facet | Zhang, Chu Feng, Xuping Wang, Jian Liu, Fei He, Yong Zhou, Weijun |
author_sort | Zhang, Chu |
collection | PubMed |
description | BACKGROUND: Detection of plant diseases in a fast and simple way is crucial for timely disease control. Conventionally, plant diseases are accurately identified by DNA, RNA or serology based methods which are time consuming, complex and expensive. Mid-infrared spectroscopy is a promising technique that simplifies the detection procedure for the disease. Mid-infrared spectroscopy was used to identify the spectral differences between healthy and infected oilseed rape leaves. Two different sample sets from two experiments were used to explore and validate the feasibility of using mid-infrared spectroscopy in detecting Sclerotinia stem rot (SSR) on oilseed rape leaves. RESULTS: The average mid-infrared spectra showed differences between healthy and infected leaves, and the differences varied among different sample sets. Optimal wavenumbers for the 2 sample sets selected by the second derivative spectra were similar, indicating the efficacy of selecting optimal wavenumbers. Chemometric methods were further used to quantitatively detect the oilseed rape leaves infected by SSR, including the partial least squares-discriminant analysis, support vector machine and extreme learning machine. The discriminant models using the full spectra and the optimal wavenumbers of the 2 sample sets were effective for classification accuracies over 80%. The discriminant results for the 2 sample sets varied due to variations in the samples. CONCLUSION: The use of two sample sets proved and validated the feasibility of using mid-infrared spectroscopy and chemometric methods for detecting SSR on oilseed rape leaves. The similarities among the selected optimal wavenumbers in different sample sets made it feasible to simplify the models and build practical models. Mid-infrared spectroscopy is a reliable and promising technique for SSR control. This study helps in developing practical application of using mid-infrared spectroscopy combined with chemometrics to detect plant disease. |
format | Online Article Text |
id | pubmed-5436460 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54364602017-05-19 Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves Zhang, Chu Feng, Xuping Wang, Jian Liu, Fei He, Yong Zhou, Weijun Plant Methods Methodology BACKGROUND: Detection of plant diseases in a fast and simple way is crucial for timely disease control. Conventionally, plant diseases are accurately identified by DNA, RNA or serology based methods which are time consuming, complex and expensive. Mid-infrared spectroscopy is a promising technique that simplifies the detection procedure for the disease. Mid-infrared spectroscopy was used to identify the spectral differences between healthy and infected oilseed rape leaves. Two different sample sets from two experiments were used to explore and validate the feasibility of using mid-infrared spectroscopy in detecting Sclerotinia stem rot (SSR) on oilseed rape leaves. RESULTS: The average mid-infrared spectra showed differences between healthy and infected leaves, and the differences varied among different sample sets. Optimal wavenumbers for the 2 sample sets selected by the second derivative spectra were similar, indicating the efficacy of selecting optimal wavenumbers. Chemometric methods were further used to quantitatively detect the oilseed rape leaves infected by SSR, including the partial least squares-discriminant analysis, support vector machine and extreme learning machine. The discriminant models using the full spectra and the optimal wavenumbers of the 2 sample sets were effective for classification accuracies over 80%. The discriminant results for the 2 sample sets varied due to variations in the samples. CONCLUSION: The use of two sample sets proved and validated the feasibility of using mid-infrared spectroscopy and chemometric methods for detecting SSR on oilseed rape leaves. The similarities among the selected optimal wavenumbers in different sample sets made it feasible to simplify the models and build practical models. Mid-infrared spectroscopy is a reliable and promising technique for SSR control. This study helps in developing practical application of using mid-infrared spectroscopy combined with chemometrics to detect plant disease. BioMed Central 2017-05-17 /pmc/articles/PMC5436460/ /pubmed/28529536 http://dx.doi.org/10.1186/s13007-017-0190-6 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Methodology Zhang, Chu Feng, Xuping Wang, Jian Liu, Fei He, Yong Zhou, Weijun Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title | Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title_full | Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title_fullStr | Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title_full_unstemmed | Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title_short | Mid-infrared spectroscopy combined with chemometrics to detect Sclerotinia stem rot on oilseed rape (Brassica napus L.) leaves |
title_sort | mid-infrared spectroscopy combined with chemometrics to detect sclerotinia stem rot on oilseed rape (brassica napus l.) leaves |
topic | Methodology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5436460/ https://www.ncbi.nlm.nih.gov/pubmed/28529536 http://dx.doi.org/10.1186/s13007-017-0190-6 |
work_keys_str_mv | AT zhangchu midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves AT fengxuping midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves AT wangjian midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves AT liufei midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves AT heyong midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves AT zhouweijun midinfraredspectroscopycombinedwithchemometricstodetectsclerotiniastemrotonoilseedrapebrassicanapuslleaves |