Cargando…

Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

INTRODUCTION: Obstructive sleep apnea (OSA) is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS) and continuous positive airway pressure (CPAP) on flu...

Descripción completa

Detalles Bibliográficos
Autores principales: Silva, Bruno C., Santos, Roberto S. S., Drager, Luciano F., Coelho, Fernando M., Elias, Rosilene M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5437164/
https://www.ncbi.nlm.nih.gov/pubmed/28580357
http://dx.doi.org/10.3389/fmed.2017.00057
_version_ 1783237540267950080
author Silva, Bruno C.
Santos, Roberto S. S.
Drager, Luciano F.
Coelho, Fernando M.
Elias, Rosilene M.
author_facet Silva, Bruno C.
Santos, Roberto S. S.
Drager, Luciano F.
Coelho, Fernando M.
Elias, Rosilene M.
author_sort Silva, Bruno C.
collection PubMed
description INTRODUCTION: Obstructive sleep apnea (OSA) is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS) and continuous positive airway pressure (CPAP) on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study. METHODS: Each participant performed polysomnography (PSG) at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC) and segmental bioelectrical impedance were done before and after PSG. RESULTS: Fourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m(2)). Apnea–hypopnea index (AHI) decreased from 20.8 (14.2; 39.6) at baseline to 7.9 (2.8; 25.4) during CPAP titration and to 16.7 (3.5; 28.9) events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017). Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03). CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively (p = 0.006). Overnight NC increased at baseline (0.7 ± 0.4 cm), decreased after CPAP (−1.0 ± 0.4 cm), and while wearing CS (−0.4 ± 0.8 cm) (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01). CONCLUSION: CS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS for both reduction of AHI and overnight reduction of NC. Complementary studies are needed to elucidate the mechanisms by which CPAP and CS reduce NC.
format Online
Article
Text
id pubmed-5437164
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-54371642017-06-02 Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis Silva, Bruno C. Santos, Roberto S. S. Drager, Luciano F. Coelho, Fernando M. Elias, Rosilene M. Front Med (Lausanne) Medicine INTRODUCTION: Obstructive sleep apnea (OSA) is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS) and continuous positive airway pressure (CPAP) on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study. METHODS: Each participant performed polysomnography (PSG) at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC) and segmental bioelectrical impedance were done before and after PSG. RESULTS: Fourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m(2)). Apnea–hypopnea index (AHI) decreased from 20.8 (14.2; 39.6) at baseline to 7.9 (2.8; 25.4) during CPAP titration and to 16.7 (3.5; 28.9) events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017). Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03). CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively (p = 0.006). Overnight NC increased at baseline (0.7 ± 0.4 cm), decreased after CPAP (−1.0 ± 0.4 cm), and while wearing CS (−0.4 ± 0.8 cm) (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01). CONCLUSION: CS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS for both reduction of AHI and overnight reduction of NC. Complementary studies are needed to elucidate the mechanisms by which CPAP and CS reduce NC. Frontiers Media S.A. 2017-05-19 /pmc/articles/PMC5437164/ /pubmed/28580357 http://dx.doi.org/10.3389/fmed.2017.00057 Text en Copyright © 2017 Silva, Santos, Drager, Coelho and Elias. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Silva, Bruno C.
Santos, Roberto S. S.
Drager, Luciano F.
Coelho, Fernando M.
Elias, Rosilene M.
Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title_full Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title_fullStr Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title_full_unstemmed Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title_short Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis
title_sort impact of compression stockings vs. continuous positive airway pressure on overnight fluid shift and obstructive sleep apnea among patients on hemodialysis
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5437164/
https://www.ncbi.nlm.nih.gov/pubmed/28580357
http://dx.doi.org/10.3389/fmed.2017.00057
work_keys_str_mv AT silvabrunoc impactofcompressionstockingsvscontinuouspositiveairwaypressureonovernightfluidshiftandobstructivesleepapneaamongpatientsonhemodialysis
AT santosrobertoss impactofcompressionstockingsvscontinuouspositiveairwaypressureonovernightfluidshiftandobstructivesleepapneaamongpatientsonhemodialysis
AT dragerlucianof impactofcompressionstockingsvscontinuouspositiveairwaypressureonovernightfluidshiftandobstructivesleepapneaamongpatientsonhemodialysis
AT coelhofernandom impactofcompressionstockingsvscontinuouspositiveairwaypressureonovernightfluidshiftandobstructivesleepapneaamongpatientsonhemodialysis
AT eliasrosilenem impactofcompressionstockingsvscontinuouspositiveairwaypressureonovernightfluidshiftandobstructivesleepapneaamongpatientsonhemodialysis