Cargando…

Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol

THE AIM: of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. MATERIALS AND METHODS: Sixty-five implants were placed in twenty-five consecutive p...

Descripción completa

Detalles Bibliográficos
Autores principales: Cristache, Corina Marilena, Gurbanescu, Silviu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5438863/
https://www.ncbi.nlm.nih.gov/pubmed/28555157
http://dx.doi.org/10.1155/2017/4292081
_version_ 1783237846695411712
author Cristache, Corina Marilena
Gurbanescu, Silviu
author_facet Cristache, Corina Marilena
Gurbanescu, Silviu
author_sort Cristache, Corina Marilena
collection PubMed
description THE AIM: of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. MATERIALS AND METHODS: Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. RESULTS: Mean (and standard deviation) of 3D error at the entry point was 0.798 mm (±0.52), at the implant apex it was 1.17 mm (±0.63), and mean angular deviation was 2.34 (±0.85). A statistically significant reduced 3D error was observed at entry point p = .037, at implant apex p = .008, and also in angular deviation p = .030 in mandible when comparing to maxilla. CONCLUSIONS: The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan) with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.
format Online
Article
Text
id pubmed-5438863
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-54388632017-05-29 Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol Cristache, Corina Marilena Gurbanescu, Silviu Int J Dent Clinical Study THE AIM: of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. MATERIALS AND METHODS: Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. RESULTS: Mean (and standard deviation) of 3D error at the entry point was 0.798 mm (±0.52), at the implant apex it was 1.17 mm (±0.63), and mean angular deviation was 2.34 (±0.85). A statistically significant reduced 3D error was observed at entry point p = .037, at implant apex p = .008, and also in angular deviation p = .030 in mandible when comparing to maxilla. CONCLUSIONS: The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan) with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning. Hindawi 2017 2017-05-07 /pmc/articles/PMC5438863/ /pubmed/28555157 http://dx.doi.org/10.1155/2017/4292081 Text en Copyright © 2017 Corina Marilena Cristache and Silviu Gurbanescu. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Cristache, Corina Marilena
Gurbanescu, Silviu
Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title_full Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title_fullStr Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title_full_unstemmed Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title_short Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol
title_sort accuracy evaluation of a stereolithographic surgical template for dental implant insertion using 3d superimposition protocol
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5438863/
https://www.ncbi.nlm.nih.gov/pubmed/28555157
http://dx.doi.org/10.1155/2017/4292081
work_keys_str_mv AT cristachecorinamarilena accuracyevaluationofastereolithographicsurgicaltemplatefordentalimplantinsertionusing3dsuperimpositionprotocol
AT gurbanescusilviu accuracyevaluationofastereolithographicsurgicaltemplatefordentalimplantinsertionusing3dsuperimpositionprotocol