Cargando…

Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System

BACKGROUND: The original knee megaprostheses with fixed or rotating hinge articulation were custom made and only used for reconstruction of the knee following distal femoral or proximal tibial tumor resections. The aim of the study was to analyze the short- and mid-term results of revision total kne...

Descripción completa

Detalles Bibliográficos
Autores principales: Marczak, Dariusz, Kowalczewski, Jacek, Czubak, Jarosław, Okoń, Tomasz, Synder, Marek, Sibiński, Marcin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5439320/
https://www.ncbi.nlm.nih.gov/pubmed/28566786
http://dx.doi.org/10.4103/0019-5413.205684
_version_ 1783237924784963584
author Marczak, Dariusz
Kowalczewski, Jacek
Czubak, Jarosław
Okoń, Tomasz
Synder, Marek
Sibiński, Marcin
author_facet Marczak, Dariusz
Kowalczewski, Jacek
Czubak, Jarosław
Okoń, Tomasz
Synder, Marek
Sibiński, Marcin
author_sort Marczak, Dariusz
collection PubMed
description BACKGROUND: The original knee megaprostheses with fixed or rotating hinge articulation were custom made and only used for reconstruction of the knee following distal femoral or proximal tibial tumor resections. The aim of the study was to analyze the short- and mid-term results of revision total knee arthroplasty with Global Modular Replacement System (GMRS) used in difficult situations not amenable to reconstruction with standard total knee replacement implants. MATERIALS AND METHODS: Nine patients (9 knees) were treated with this comprehensive modular implant system, with a mean age of 73.7 years (range 56–83 years) and a mean followup of 5 years (range 3–8 years). Two patients were treated for distal femoral nonunion, five for distal femur periprosthetic fracture and two for periprosthetic joint infection. RESULTS: The mean Knee Society Score: Knee and functional scores were 77.9 and 40 points, respectively. All demonstrated full extension and flexion was at least 90°. Recurrence of infection was present in one patient. No signs of loosening, dislocation, or implant failure were observed. CONCLUSIONS: Based on our small series of patients that represent severe cases, GMRS provides relatively good mid-term functional results, pain relief, and good implant survivorship with a low complication rate. This salvage procedure allows elderly, infirm patients to regain early ambulatory ability.
format Online
Article
Text
id pubmed-5439320
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-54393202017-05-31 Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System Marczak, Dariusz Kowalczewski, Jacek Czubak, Jarosław Okoń, Tomasz Synder, Marek Sibiński, Marcin Indian J Orthop Original Article BACKGROUND: The original knee megaprostheses with fixed or rotating hinge articulation were custom made and only used for reconstruction of the knee following distal femoral or proximal tibial tumor resections. The aim of the study was to analyze the short- and mid-term results of revision total knee arthroplasty with Global Modular Replacement System (GMRS) used in difficult situations not amenable to reconstruction with standard total knee replacement implants. MATERIALS AND METHODS: Nine patients (9 knees) were treated with this comprehensive modular implant system, with a mean age of 73.7 years (range 56–83 years) and a mean followup of 5 years (range 3–8 years). Two patients were treated for distal femoral nonunion, five for distal femur periprosthetic fracture and two for periprosthetic joint infection. RESULTS: The mean Knee Society Score: Knee and functional scores were 77.9 and 40 points, respectively. All demonstrated full extension and flexion was at least 90°. Recurrence of infection was present in one patient. No signs of loosening, dislocation, or implant failure were observed. CONCLUSIONS: Based on our small series of patients that represent severe cases, GMRS provides relatively good mid-term functional results, pain relief, and good implant survivorship with a low complication rate. This salvage procedure allows elderly, infirm patients to regain early ambulatory ability. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5439320/ /pubmed/28566786 http://dx.doi.org/10.4103/0019-5413.205684 Text en Copyright: © 2017 Indian Journal of Orthopaedics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Marczak, Dariusz
Kowalczewski, Jacek
Czubak, Jarosław
Okoń, Tomasz
Synder, Marek
Sibiński, Marcin
Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title_full Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title_fullStr Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title_full_unstemmed Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title_short Short and mid term results of revision total knee arthroplasty with Global Modular Replacement System
title_sort short and mid term results of revision total knee arthroplasty with global modular replacement system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5439320/
https://www.ncbi.nlm.nih.gov/pubmed/28566786
http://dx.doi.org/10.4103/0019-5413.205684
work_keys_str_mv AT marczakdariusz shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem
AT kowalczewskijacek shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem
AT czubakjarosław shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem
AT okontomasz shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem
AT syndermarek shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem
AT sibinskimarcin shortandmidtermresultsofrevisiontotalkneearthroplastywithglobalmodularreplacementsystem