Cargando…

Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma

We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy...

Descripción completa

Detalles Bibliográficos
Autores principales: Inoue, Toshihiko, Masai, Norihisa, Shiomi, Hiroya, Oh, Ryoong-Jin, Uemoto, Kenji, Hashida, Noriyasu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5440859/
https://www.ncbi.nlm.nih.gov/pubmed/27811199
http://dx.doi.org/10.1093/jrr/rrw104
_version_ 1783238143242141696
author Inoue, Toshihiko
Masai, Norihisa
Shiomi, Hiroya
Oh, Ryoong-Jin
Uemoto, Kenji
Hashida, Noriyasu
author_facet Inoue, Toshihiko
Masai, Norihisa
Shiomi, Hiroya
Oh, Ryoong-Jin
Uemoto, Kenji
Hashida, Noriyasu
author_sort Inoue, Toshihiko
collection PubMed
description We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy (IMRT). The device consists of an immobilization shell, a right-angle prism mirror, a high magnification optical zoom video camera, a guide lamp, a digital voice recorder, a personal computer, and a National Television System Committee standard analog video cable. Using the right-angle prism mirror, the antero–posterior axis was determined coincident with the optic axis connecting the centers of the cornea and pupil. The axis was then connected to the guide light and video camera installed on the couch top on the distal side. Repositioning accuracy improved using this method. Furthermore, the positional error of the lens was markedly reduced from ±1.16, ±1.68 and ±1.11 mm to ±0.23, ±0.58 and ±0.26 mm in the horizontal direction, and from ±1.50, ±1.03 and ±0.48 mm to ±0.29, ±0.30 and ±0.24 mm in the vertical direction (Patient #1, #2 and #3, respectively). Accordingly, the F-M device method decreased the planning target volume size and improved the dose–volume histogram parameters of the organ-at-risk via IMRT inverse planning. Importantly, the treatment method was well tolerated.
format Online
Article
Text
id pubmed-5440859
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-54408592017-05-30 Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma Inoue, Toshihiko Masai, Norihisa Shiomi, Hiroya Oh, Ryoong-Jin Uemoto, Kenji Hashida, Noriyasu J Radiat Res Oncology We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy (IMRT). The device consists of an immobilization shell, a right-angle prism mirror, a high magnification optical zoom video camera, a guide lamp, a digital voice recorder, a personal computer, and a National Television System Committee standard analog video cable. Using the right-angle prism mirror, the antero–posterior axis was determined coincident with the optic axis connecting the centers of the cornea and pupil. The axis was then connected to the guide light and video camera installed on the couch top on the distal side. Repositioning accuracy improved using this method. Furthermore, the positional error of the lens was markedly reduced from ±1.16, ±1.68 and ±1.11 mm to ±0.23, ±0.58 and ±0.26 mm in the horizontal direction, and from ±1.50, ±1.03 and ±0.48 mm to ±0.29, ±0.30 and ±0.24 mm in the vertical direction (Patient #1, #2 and #3, respectively). Accordingly, the F-M device method decreased the planning target volume size and improved the dose–volume histogram parameters of the organ-at-risk via IMRT inverse planning. Importantly, the treatment method was well tolerated. Oxford University Press 2017-05 2016-11-03 /pmc/articles/PMC5440859/ /pubmed/27811199 http://dx.doi.org/10.1093/jrr/rrw104 Text en © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the originalwork is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Oncology
Inoue, Toshihiko
Masai, Norihisa
Shiomi, Hiroya
Oh, Ryoong-Jin
Uemoto, Kenji
Hashida, Noriyasu
Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title_full Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title_fullStr Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title_full_unstemmed Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title_short Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
title_sort feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5440859/
https://www.ncbi.nlm.nih.gov/pubmed/27811199
http://dx.doi.org/10.1093/jrr/rrw104
work_keys_str_mv AT inouetoshihiko feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma
AT masainorihisa feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma
AT shiomihiroya feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma
AT ohryoongjin feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma
AT uemotokenji feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma
AT hashidanoriyasu feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma