Cargando…
Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma
We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5440859/ https://www.ncbi.nlm.nih.gov/pubmed/27811199 http://dx.doi.org/10.1093/jrr/rrw104 |
_version_ | 1783238143242141696 |
---|---|
author | Inoue, Toshihiko Masai, Norihisa Shiomi, Hiroya Oh, Ryoong-Jin Uemoto, Kenji Hashida, Noriyasu |
author_facet | Inoue, Toshihiko Masai, Norihisa Shiomi, Hiroya Oh, Ryoong-Jin Uemoto, Kenji Hashida, Noriyasu |
author_sort | Inoue, Toshihiko |
collection | PubMed |
description | We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy (IMRT). The device consists of an immobilization shell, a right-angle prism mirror, a high magnification optical zoom video camera, a guide lamp, a digital voice recorder, a personal computer, and a National Television System Committee standard analog video cable. Using the right-angle prism mirror, the antero–posterior axis was determined coincident with the optic axis connecting the centers of the cornea and pupil. The axis was then connected to the guide light and video camera installed on the couch top on the distal side. Repositioning accuracy improved using this method. Furthermore, the positional error of the lens was markedly reduced from ±1.16, ±1.68 and ±1.11 mm to ±0.23, ±0.58 and ±0.26 mm in the horizontal direction, and from ±1.50, ±1.03 and ±0.48 mm to ±0.29, ±0.30 and ±0.24 mm in the vertical direction (Patient #1, #2 and #3, respectively). Accordingly, the F-M device method decreased the planning target volume size and improved the dose–volume histogram parameters of the organ-at-risk via IMRT inverse planning. Importantly, the treatment method was well tolerated. |
format | Online Article Text |
id | pubmed-5440859 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-54408592017-05-30 Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma Inoue, Toshihiko Masai, Norihisa Shiomi, Hiroya Oh, Ryoong-Jin Uemoto, Kenji Hashida, Noriyasu J Radiat Res Oncology We aimed to describe the feasibility and efficacy of a novel non-invasive fixation and monitoring (F-M) device for the eyeballs (which uses a right-angle prism mirror as the optic axis guide) in three consecutive patients with choroidal melanoma who were treated with intensity-modulated radiotherapy (IMRT). The device consists of an immobilization shell, a right-angle prism mirror, a high magnification optical zoom video camera, a guide lamp, a digital voice recorder, a personal computer, and a National Television System Committee standard analog video cable. Using the right-angle prism mirror, the antero–posterior axis was determined coincident with the optic axis connecting the centers of the cornea and pupil. The axis was then connected to the guide light and video camera installed on the couch top on the distal side. Repositioning accuracy improved using this method. Furthermore, the positional error of the lens was markedly reduced from ±1.16, ±1.68 and ±1.11 mm to ±0.23, ±0.58 and ±0.26 mm in the horizontal direction, and from ±1.50, ±1.03 and ±0.48 mm to ±0.29, ±0.30 and ±0.24 mm in the vertical direction (Patient #1, #2 and #3, respectively). Accordingly, the F-M device method decreased the planning target volume size and improved the dose–volume histogram parameters of the organ-at-risk via IMRT inverse planning. Importantly, the treatment method was well tolerated. Oxford University Press 2017-05 2016-11-03 /pmc/articles/PMC5440859/ /pubmed/27811199 http://dx.doi.org/10.1093/jrr/rrw104 Text en © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the originalwork is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Oncology Inoue, Toshihiko Masai, Norihisa Shiomi, Hiroya Oh, Ryoong-Jin Uemoto, Kenji Hashida, Noriyasu Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title | Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title_full | Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title_fullStr | Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title_full_unstemmed | Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title_short | Feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
title_sort | feasibility study of a non-invasive eye fixation and monitoring device using a right-angle prism mirror for intensity-modulated radiotherapy for choroidal melanoma |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5440859/ https://www.ncbi.nlm.nih.gov/pubmed/27811199 http://dx.doi.org/10.1093/jrr/rrw104 |
work_keys_str_mv | AT inouetoshihiko feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma AT masainorihisa feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma AT shiomihiroya feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma AT ohryoongjin feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma AT uemotokenji feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma AT hashidanoriyasu feasibilitystudyofanoninvasiveeyefixationandmonitoringdeviceusingarightangleprismmirrorforintensitymodulatedradiotherapyforchoroidalmelanoma |