Cargando…

An objective assessment of the variability in number of drops per bottle of glaucoma medication

BACKGROUND: The purpose of this study is to evaluate the number of eyedrops available per bottle of a variety of commonly prescribed glaucoma medications. METHODS: Six bottles of each glaucoma medication were tested: three each in the vertical and horizontal orientations. Bottles were housed in a cu...

Descripción completa

Detalles Bibliográficos
Autores principales: Moore, Daniel B., Beck, Judy, Kryscio, Richard J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5441018/
https://www.ncbi.nlm.nih.gov/pubmed/28532424
http://dx.doi.org/10.1186/s12886-017-0473-8
_version_ 1783238179932864512
author Moore, Daniel B.
Beck, Judy
Kryscio, Richard J
author_facet Moore, Daniel B.
Beck, Judy
Kryscio, Richard J
author_sort Moore, Daniel B.
collection PubMed
description BACKGROUND: The purpose of this study is to evaluate the number of eyedrops available per bottle of a variety of commonly prescribed glaucoma medications. METHODS: Six bottles of each glaucoma medication were tested: three each in the vertical and horizontal orientations. Bottles were housed in a customized force gauge apparatus designed to mimic ballpoint fingertip contact with a bottle. At a standard rate, all drops were expressed from each bottle and counted with an automated drop counter. Simultaneously, bottle volume was measured and drop size and number were also estimated. The main outcome measures were: total number of drops, volume per bottle and drops per milliliter (mL) of glaucoma medication. RESULTS: A total of 192 bottles from 32 bottle designs and manufacturers were tested. Twenty-two of the 32 bottle designs had a significantly different mean number of drops in the vertical and horizontal positions, with 10 designs have more drops dispensed in the horizontal orientation and 12 in the vertical orientation. Six of the 32 bottle designs had a significantly different mean total bottle volume in the vertical and horizontal positions, with all designs having greater volume in the vertical position. An adjusted ratio of mean number of drops/mean bottle volume demonstrated a range from 20.9 drops/mL to 40.8 drops/mL. CONCLUSIONS: There is significant variability in drops and volume available per bottle of glaucoma medication depending on both the bottle position and manufacturer. These data point to the need for circumspection in prescribing glaucoma medications and caution in evaluating therapeutic outcomes.
format Online
Article
Text
id pubmed-5441018
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-54410182017-05-24 An objective assessment of the variability in number of drops per bottle of glaucoma medication Moore, Daniel B. Beck, Judy Kryscio, Richard J BMC Ophthalmol Research Article BACKGROUND: The purpose of this study is to evaluate the number of eyedrops available per bottle of a variety of commonly prescribed glaucoma medications. METHODS: Six bottles of each glaucoma medication were tested: three each in the vertical and horizontal orientations. Bottles were housed in a customized force gauge apparatus designed to mimic ballpoint fingertip contact with a bottle. At a standard rate, all drops were expressed from each bottle and counted with an automated drop counter. Simultaneously, bottle volume was measured and drop size and number were also estimated. The main outcome measures were: total number of drops, volume per bottle and drops per milliliter (mL) of glaucoma medication. RESULTS: A total of 192 bottles from 32 bottle designs and manufacturers were tested. Twenty-two of the 32 bottle designs had a significantly different mean number of drops in the vertical and horizontal positions, with 10 designs have more drops dispensed in the horizontal orientation and 12 in the vertical orientation. Six of the 32 bottle designs had a significantly different mean total bottle volume in the vertical and horizontal positions, with all designs having greater volume in the vertical position. An adjusted ratio of mean number of drops/mean bottle volume demonstrated a range from 20.9 drops/mL to 40.8 drops/mL. CONCLUSIONS: There is significant variability in drops and volume available per bottle of glaucoma medication depending on both the bottle position and manufacturer. These data point to the need for circumspection in prescribing glaucoma medications and caution in evaluating therapeutic outcomes. BioMed Central 2017-05-22 /pmc/articles/PMC5441018/ /pubmed/28532424 http://dx.doi.org/10.1186/s12886-017-0473-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Moore, Daniel B.
Beck, Judy
Kryscio, Richard J
An objective assessment of the variability in number of drops per bottle of glaucoma medication
title An objective assessment of the variability in number of drops per bottle of glaucoma medication
title_full An objective assessment of the variability in number of drops per bottle of glaucoma medication
title_fullStr An objective assessment of the variability in number of drops per bottle of glaucoma medication
title_full_unstemmed An objective assessment of the variability in number of drops per bottle of glaucoma medication
title_short An objective assessment of the variability in number of drops per bottle of glaucoma medication
title_sort objective assessment of the variability in number of drops per bottle of glaucoma medication
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5441018/
https://www.ncbi.nlm.nih.gov/pubmed/28532424
http://dx.doi.org/10.1186/s12886-017-0473-8
work_keys_str_mv AT mooredanielb anobjectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication
AT beckjudy anobjectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication
AT krysciorichardj anobjectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication
AT mooredanielb objectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication
AT beckjudy objectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication
AT krysciorichardj objectiveassessmentofthevariabilityinnumberofdropsperbottleofglaucomamedication