Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function

BACKGROUND: This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). METHODS: In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from b...

Descripción completa

Detalles Bibliográficos
Autores principales: Tedesco-Silva, Helio, Mello Offerni, Juliano Chrystian, Ayres Carneiro, Vanessa, Ivani de Paula, Mayara, Neto, Elias David, Brambate Carvalhinho Lemos, Francine, Requião Moura, Lúcio Roberto, Pacheco e Silva Filho, Alvaro, de Morais Cunha, Mirian de Fátima, Francisco da Silva, Erica, Miorin, Luiz Antonio, Demetrio, Daniela Priscila, Luconi, Paulo Sérgio, da Silva Luconi, Waldere Tania, Bobbio, Savina Adriana, kuschnaroff, Liz Milstein, Noronha, Irene Lourdes, Braga, Sibele Lessa, Barsante, Renata Cristina, Mendes Moreira, João Cezar, Fernandes-Charpiot, Ida Maria Maximina, Abbud-Filho, Mario, Modelli de Andrade, Luis Gustavo, Dalsoglio Garcia, Paula, Tanajura Santamaria Saber, Luciana, Fernandes Laurindo, Alan, Chocair, Pedro Renato, Cuvello Neto, Américo Lourenço, Zanocco, Juliana Aparecida, Duboc de Almeida Soares Filho, Antonio Jose, Ferreira Aguiar, Wilson, Medina Pestana, Jose
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5441986/
https://www.ncbi.nlm.nih.gov/pubmed/28573190
http://dx.doi.org/10.1097/TXD.0000000000000672
_version_ 1783238324913176576
author Tedesco-Silva, Helio
Mello Offerni, Juliano Chrystian
Ayres Carneiro, Vanessa
Ivani de Paula, Mayara
Neto, Elias David
Brambate Carvalhinho Lemos, Francine
Requião Moura, Lúcio Roberto
Pacheco e Silva Filho, Alvaro
de Morais Cunha, Mirian de Fátima
Francisco da Silva, Erica
Miorin, Luiz Antonio
Demetrio, Daniela Priscila
Luconi, Paulo Sérgio
da Silva Luconi, Waldere Tania
Bobbio, Savina Adriana
kuschnaroff, Liz Milstein
Noronha, Irene Lourdes
Braga, Sibele Lessa
Barsante, Renata Cristina
Mendes Moreira, João Cezar
Fernandes-Charpiot, Ida Maria Maximina
Abbud-Filho, Mario
Modelli de Andrade, Luis Gustavo
Dalsoglio Garcia, Paula
Tanajura Santamaria Saber, Luciana
Fernandes Laurindo, Alan
Chocair, Pedro Renato
Cuvello Neto, Américo Lourenço
Zanocco, Juliana Aparecida
Duboc de Almeida Soares Filho, Antonio Jose
Ferreira Aguiar, Wilson
Medina Pestana, Jose
author_facet Tedesco-Silva, Helio
Mello Offerni, Juliano Chrystian
Ayres Carneiro, Vanessa
Ivani de Paula, Mayara
Neto, Elias David
Brambate Carvalhinho Lemos, Francine
Requião Moura, Lúcio Roberto
Pacheco e Silva Filho, Alvaro
de Morais Cunha, Mirian de Fátima
Francisco da Silva, Erica
Miorin, Luiz Antonio
Demetrio, Daniela Priscila
Luconi, Paulo Sérgio
da Silva Luconi, Waldere Tania
Bobbio, Savina Adriana
kuschnaroff, Liz Milstein
Noronha, Irene Lourdes
Braga, Sibele Lessa
Barsante, Renata Cristina
Mendes Moreira, João Cezar
Fernandes-Charpiot, Ida Maria Maximina
Abbud-Filho, Mario
Modelli de Andrade, Luis Gustavo
Dalsoglio Garcia, Paula
Tanajura Santamaria Saber, Luciana
Fernandes Laurindo, Alan
Chocair, Pedro Renato
Cuvello Neto, Américo Lourenço
Zanocco, Juliana Aparecida
Duboc de Almeida Soares Filho, Antonio Jose
Ferreira Aguiar, Wilson
Medina Pestana, Jose
author_sort Tedesco-Silva, Helio
collection PubMed
description BACKGROUND: This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). METHODS: In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. RESULTS: Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m(2) vs 49.0 ± 26.9 mL/min per 1.73 m(2); P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m(2) vs 54.4 ± 28.6 mL/min per 1.73 m(2); P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. CONCLUSIONS: In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method.
format Online
Article
Text
id pubmed-5441986
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-54419862017-06-01 Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function Tedesco-Silva, Helio Mello Offerni, Juliano Chrystian Ayres Carneiro, Vanessa Ivani de Paula, Mayara Neto, Elias David Brambate Carvalhinho Lemos, Francine Requião Moura, Lúcio Roberto Pacheco e Silva Filho, Alvaro de Morais Cunha, Mirian de Fátima Francisco da Silva, Erica Miorin, Luiz Antonio Demetrio, Daniela Priscila Luconi, Paulo Sérgio da Silva Luconi, Waldere Tania Bobbio, Savina Adriana kuschnaroff, Liz Milstein Noronha, Irene Lourdes Braga, Sibele Lessa Barsante, Renata Cristina Mendes Moreira, João Cezar Fernandes-Charpiot, Ida Maria Maximina Abbud-Filho, Mario Modelli de Andrade, Luis Gustavo Dalsoglio Garcia, Paula Tanajura Santamaria Saber, Luciana Fernandes Laurindo, Alan Chocair, Pedro Renato Cuvello Neto, Américo Lourenço Zanocco, Juliana Aparecida Duboc de Almeida Soares Filho, Antonio Jose Ferreira Aguiar, Wilson Medina Pestana, Jose Transplant Direct Kidney Transplantation BACKGROUND: This study compared the use of static cold storage versus continuous hypothermic machine perfusion in a cohort of kidney transplant recipients at high risk for delayed graft function (DGF). METHODS: In this national, multicenter, and controlled trial, 80 pairs of kidneys recovered from brain-dead deceased donors were randomized to cold storage or machine perfusion, transplanted, and followed up for 12 months. The primary endpoint was the incidence of DGF. Secondary endpoints included the duration of DGF, hospital stay, primary nonfunction, estimated glomerular filtration rate, acute rejection, and allograft and patient survivals. RESULTS: Mean cold ischemia time was high but not different between the 2 groups (25.6 ± 6.6 hours vs 25.05 ± 6.3 hours, 0.937). The incidence of DGF was lower in the machine perfusion compared with cold storage group (61% vs. 45%, P = 0.031). Machine perfusion was independently associated with a reduced risk of DGF (odds ratio, 0.49; 95% confidence interval, 0.26-0.95). Mean estimated glomerular filtration rate tended to be higher at day 28 (40.6 ± 19.9 mL/min per 1.73 m(2) vs 49.0 ± 26.9 mL/min per 1.73 m(2); P = 0.262) and 1 year (48.3 ± 19.8 mL/min per 1.73 m(2) vs 54.4 ± 28.6 mL/min per 1.73 m(2); P = 0.201) in the machine perfusion group. No differences in the incidence of acute rejection, primary nonfunction (0% vs 2.5%), graft loss (7.5% vs 10%), or death (8.8% vs 6.3%) were observed. CONCLUSIONS: In this cohort of recipients of deceased donor kidneys with high mean cold ischemia time and high incidence of DGF, the use of continuous machine perfusion was associated with a reduced risk of DGF compared with the traditional cold storage preservation method. Lippincott Williams & Wilkins 2017-04-18 /pmc/articles/PMC5441986/ /pubmed/28573190 http://dx.doi.org/10.1097/TXD.0000000000000672 Text en Copyright © 2017 The Author(s). Transplantation Direct. Published by Wolters Kluwer Health, Inc. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (http://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Kidney Transplantation
Tedesco-Silva, Helio
Mello Offerni, Juliano Chrystian
Ayres Carneiro, Vanessa
Ivani de Paula, Mayara
Neto, Elias David
Brambate Carvalhinho Lemos, Francine
Requião Moura, Lúcio Roberto
Pacheco e Silva Filho, Alvaro
de Morais Cunha, Mirian de Fátima
Francisco da Silva, Erica
Miorin, Luiz Antonio
Demetrio, Daniela Priscila
Luconi, Paulo Sérgio
da Silva Luconi, Waldere Tania
Bobbio, Savina Adriana
kuschnaroff, Liz Milstein
Noronha, Irene Lourdes
Braga, Sibele Lessa
Barsante, Renata Cristina
Mendes Moreira, João Cezar
Fernandes-Charpiot, Ida Maria Maximina
Abbud-Filho, Mario
Modelli de Andrade, Luis Gustavo
Dalsoglio Garcia, Paula
Tanajura Santamaria Saber, Luciana
Fernandes Laurindo, Alan
Chocair, Pedro Renato
Cuvello Neto, Américo Lourenço
Zanocco, Juliana Aparecida
Duboc de Almeida Soares Filho, Antonio Jose
Ferreira Aguiar, Wilson
Medina Pestana, Jose
Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title_full Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title_fullStr Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title_full_unstemmed Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title_short Randomized Trial of Machine Perfusion Versus Cold Storage in Recipients of Deceased Donor Kidney Transplants With High Incidence of Delayed Graft Function
title_sort randomized trial of machine perfusion versus cold storage in recipients of deceased donor kidney transplants with high incidence of delayed graft function
topic Kidney Transplantation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5441986/
https://www.ncbi.nlm.nih.gov/pubmed/28573190
http://dx.doi.org/10.1097/TXD.0000000000000672
work_keys_str_mv AT tedescosilvahelio randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT mellooffernijulianochrystian randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT ayrescarneirovanessa randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT ivanidepaulamayara randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT netoeliasdavid randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT brambatecarvalhinholemosfrancine randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT requiaomouralucioroberto randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT pachecoesilvafilhoalvaro randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT demoraiscunhamiriandefatima randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT franciscodasilvaerica randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT miorinluizantonio randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT demetriodanielapriscila randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT luconipaulosergio randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT dasilvaluconiwalderetania randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT bobbiosavinaadriana randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT kuschnarofflizmilstein randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT noronhairenelourdes randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT bragasibelelessa randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT barsanterenatacristina randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT mendesmoreirajoaocezar randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT fernandescharpiotidamariamaximina randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT abbudfilhomario randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT modellideandradeluisgustavo randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT dalsogliogarciapaula randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT tanajurasantamariasaberluciana randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT fernandeslaurindoalan randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT chocairpedrorenato randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT cuvellonetoamericolourenco randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT zanoccojulianaaparecida randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT dubocdealmeidasoaresfilhoantoniojose randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT ferreiraaguiarwilson randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction
AT medinapestanajose randomizedtrialofmachineperfusionversuscoldstorageinrecipientsofdeceaseddonorkidneytransplantswithhighincidenceofdelayedgraftfunction