Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer

Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compar...

Descripción completa

Detalles Bibliográficos
Autores principales: Gao, Feng, Liu, Xu, Zhao, Qing, Pan, Yingzhe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443276/
https://www.ncbi.nlm.nih.gov/pubmed/28565785
http://dx.doi.org/10.3892/etm.2017.4164
_version_ 1783238545453875200
author Gao, Feng
Liu, Xu
Zhao, Qing
Pan, Yingzhe
author_facet Gao, Feng
Liu, Xu
Zhao, Qing
Pan, Yingzhe
author_sort Gao, Feng
collection PubMed
description Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7–15 mmHg, n=74; group B, 16–22 mmHg, n=218; and group C, 23–50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30±5.10 and 18.52±4.46 mmHg, respectively. There were no significant differences between them (t=−1.31, P=0.19). The 95% confidence interval of the differences between the two devices was −5.80–6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=−2.84, P=0.007) lower (−1.66±3.87 mmHg) than those obtained with GAT when GAT ≥23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
format Online
Article
Text
id pubmed-5443276
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-54432762017-05-30 Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer Gao, Feng Liu, Xu Zhao, Qing Pan, Yingzhe Exp Ther Med Articles Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7–15 mmHg, n=74; group B, 16–22 mmHg, n=218; and group C, 23–50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30±5.10 and 18.52±4.46 mmHg, respectively. There were no significant differences between them (t=−1.31, P=0.19). The 95% confidence interval of the differences between the two devices was −5.80–6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=−2.84, P=0.007) lower (−1.66±3.87 mmHg) than those obtained with GAT when GAT ≥23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT. D.A. Spandidos 2017-05 2017-02-24 /pmc/articles/PMC5443276/ /pubmed/28565785 http://dx.doi.org/10.3892/etm.2017.4164 Text en Copyright: © Gao et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Gao, Feng
Liu, Xu
Zhao, Qing
Pan, Yingzhe
Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title_full Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title_fullStr Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title_full_unstemmed Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title_short Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer
title_sort comparison of the icare rebound tonometer and the goldmann applanation tonometer
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443276/
https://www.ncbi.nlm.nih.gov/pubmed/28565785
http://dx.doi.org/10.3892/etm.2017.4164
work_keys_str_mv AT gaofeng comparisonoftheicarereboundtonometerandthegoldmannapplanationtonometer
AT liuxu comparisonoftheicarereboundtonometerandthegoldmannapplanationtonometer
AT zhaoqing comparisonoftheicarereboundtonometerandthegoldmannapplanationtonometer
AT panyingzhe comparisonoftheicarereboundtonometerandthegoldmannapplanationtonometer