Cargando…

Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

BACKGROUND: Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. PURPOSE: As the diagnostic accuracy of MRI techniques to detect tumor residual or recurr...

Descripción completa

Detalles Bibliográficos
Autores principales: van der Hoorn, Anouk, van Laar, Peter Jan, Holtman, Gea A., Westerlaan, Henriette E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443521/
https://www.ncbi.nlm.nih.gov/pubmed/28542474
http://dx.doi.org/10.1371/journal.pone.0177986
_version_ 1783238582322855936
author van der Hoorn, Anouk
van Laar, Peter Jan
Holtman, Gea A.
Westerlaan, Henriette E.
author_facet van der Hoorn, Anouk
van Laar, Peter Jan
Holtman, Gea A.
Westerlaan, Henriette E.
author_sort van der Hoorn, Anouk
collection PubMed
description BACKGROUND: Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. PURPOSE: As the diagnostic accuracy of MRI techniques to detect tumor residual or recurrence during or after treatment is variable reported in the literature, we performed a systematic meta-analysis. DATA SOURCES: Pubmed, EMBASE and Web of Science were searched from their first record to September 23(th) 2014. STUDY SELECTION: Studies reporting diagnostic accuracy of anatomical, ADC, perfusion or spectroscopy to identify tumor response confirmed by histology or follow-up in treated patients for head and neck tumors were selected by two authors independently. DATA ANALYSIS: Two authors independently performed data extraction including true positives, false positives, true negatives, false negatives and general study characteristics. Meta-analysis was performed using bivariate random effect models when ≥5 studies per test were included. DATA SYNTHESIS: We identified 16 relevant studies with anatomical MRI and ADC. No perfusion or spectroscopy studies were identified. Pooled analysis of anatomical MRI of the primary site (11 studies, N = 854) displayed a sensitivity of 84% (95%CI 72–92) and specificity of 82% (71–89). ADC of the primary site (6 studies, N = 287) showed a pooled sensitivity of 89% (74–96) and specificity of 86% (69–94). LIMITATIONS: Main limitation are the low, but comparable quality of the included studies and the variability between the studies. CONCLUSIONS: The higher diagnostic accuracy of ADC values over anatomical MRI for the primary tumor location emphases the relevance to include DWI with ADC for response evaluation of treated head and neck tumor patients.
format Online
Article
Text
id pubmed-5443521
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54435212017-06-06 Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis van der Hoorn, Anouk van Laar, Peter Jan Holtman, Gea A. Westerlaan, Henriette E. PLoS One Research Article BACKGROUND: Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. PURPOSE: As the diagnostic accuracy of MRI techniques to detect tumor residual or recurrence during or after treatment is variable reported in the literature, we performed a systematic meta-analysis. DATA SOURCES: Pubmed, EMBASE and Web of Science were searched from their first record to September 23(th) 2014. STUDY SELECTION: Studies reporting diagnostic accuracy of anatomical, ADC, perfusion or spectroscopy to identify tumor response confirmed by histology or follow-up in treated patients for head and neck tumors were selected by two authors independently. DATA ANALYSIS: Two authors independently performed data extraction including true positives, false positives, true negatives, false negatives and general study characteristics. Meta-analysis was performed using bivariate random effect models when ≥5 studies per test were included. DATA SYNTHESIS: We identified 16 relevant studies with anatomical MRI and ADC. No perfusion or spectroscopy studies were identified. Pooled analysis of anatomical MRI of the primary site (11 studies, N = 854) displayed a sensitivity of 84% (95%CI 72–92) and specificity of 82% (71–89). ADC of the primary site (6 studies, N = 287) showed a pooled sensitivity of 89% (74–96) and specificity of 86% (69–94). LIMITATIONS: Main limitation are the low, but comparable quality of the included studies and the variability between the studies. CONCLUSIONS: The higher diagnostic accuracy of ADC values over anatomical MRI for the primary tumor location emphases the relevance to include DWI with ADC for response evaluation of treated head and neck tumor patients. Public Library of Science 2017-05-24 /pmc/articles/PMC5443521/ /pubmed/28542474 http://dx.doi.org/10.1371/journal.pone.0177986 Text en © 2017 van der Hoorn et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
van der Hoorn, Anouk
van Laar, Peter Jan
Holtman, Gea A.
Westerlaan, Henriette E.
Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title_full Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title_fullStr Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title_full_unstemmed Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title_short Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
title_sort diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443521/
https://www.ncbi.nlm.nih.gov/pubmed/28542474
http://dx.doi.org/10.1371/journal.pone.0177986
work_keys_str_mv AT vanderhoornanouk diagnosticaccuracyofmagneticresonanceimagingtechniquesfortreatmentresponseevaluationinpatientswithheadandnecktumorsasystematicreviewandmetaanalysis
AT vanlaarpeterjan diagnosticaccuracyofmagneticresonanceimagingtechniquesfortreatmentresponseevaluationinpatientswithheadandnecktumorsasystematicreviewandmetaanalysis
AT holtmangeaa diagnosticaccuracyofmagneticresonanceimagingtechniquesfortreatmentresponseevaluationinpatientswithheadandnecktumorsasystematicreviewandmetaanalysis
AT westerlaanhenriettee diagnosticaccuracyofmagneticresonanceimagingtechniquesfortreatmentresponseevaluationinpatientswithheadandnecktumorsasystematicreviewandmetaanalysis