Cargando…
Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement
In spinal degenerative disease, an injectable liquid hydrogel can fill in defect entirely, lessen the danger of implant relocation and following loss of disc height, minimizing the operative trauma. Here, we propose an injectable in-situ chemically cross-linked hydrogel by a two-component reaction o...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443820/ https://www.ncbi.nlm.nih.gov/pubmed/28539658 http://dx.doi.org/10.1038/s41598-017-02497-3 |
_version_ | 1783238626566471680 |
---|---|
author | Hu, Jingen Lu, Yang Cai, Ling Owusu-Ansah, Kwabena Gyabaah Xu, Gewen Han, Feilong Bao, Junjie Lin, Xiangjin Huang, Yiping |
author_facet | Hu, Jingen Lu, Yang Cai, Ling Owusu-Ansah, Kwabena Gyabaah Xu, Gewen Han, Feilong Bao, Junjie Lin, Xiangjin Huang, Yiping |
author_sort | Hu, Jingen |
collection | PubMed |
description | In spinal degenerative disease, an injectable liquid hydrogel can fill in defect entirely, lessen the danger of implant relocation and following loss of disc height, minimizing the operative trauma. Here, we propose an injectable in-situ chemically cross-linked hydrogel by a two-component reaction of liquid silk fibroin with liquid polyurethane at physiological temperature conditions. Confined compression tests and fatigue tests were reported to assess physical properties of the hydrogel. Impact of different diameter on the biomechanical behaviours was tested to evaluate the clinical potentiality of the hydrogel for replacing nucleus pulposus. Degradation behaviours in different solutions and animal experiments were also investigated to examine the tissue biocompatibility of the hydrogel. The hydrogel modulus was affected by the hydrogel geometrical (diameter) parameters. SF/PU composite hydrogel can survive a million cycles, unconstrained fatigue resistance. More importantly, in vivo biocompatibility using New Zealand white rabbits, showed good biocompatibility over a three-month period in culture. Particularly, they showed the significant clinical merit of providing stronger axial compressive stiffness on confined compression test. Based on the outcomes of the present research, the SF/PU composite hydrogel may provide significant advantages for use in future clinical application in replacing nucleus pulposus field. |
format | Online Article Text |
id | pubmed-5443820 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-54438202017-05-26 Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement Hu, Jingen Lu, Yang Cai, Ling Owusu-Ansah, Kwabena Gyabaah Xu, Gewen Han, Feilong Bao, Junjie Lin, Xiangjin Huang, Yiping Sci Rep Article In spinal degenerative disease, an injectable liquid hydrogel can fill in defect entirely, lessen the danger of implant relocation and following loss of disc height, minimizing the operative trauma. Here, we propose an injectable in-situ chemically cross-linked hydrogel by a two-component reaction of liquid silk fibroin with liquid polyurethane at physiological temperature conditions. Confined compression tests and fatigue tests were reported to assess physical properties of the hydrogel. Impact of different diameter on the biomechanical behaviours was tested to evaluate the clinical potentiality of the hydrogel for replacing nucleus pulposus. Degradation behaviours in different solutions and animal experiments were also investigated to examine the tissue biocompatibility of the hydrogel. The hydrogel modulus was affected by the hydrogel geometrical (diameter) parameters. SF/PU composite hydrogel can survive a million cycles, unconstrained fatigue resistance. More importantly, in vivo biocompatibility using New Zealand white rabbits, showed good biocompatibility over a three-month period in culture. Particularly, they showed the significant clinical merit of providing stronger axial compressive stiffness on confined compression test. Based on the outcomes of the present research, the SF/PU composite hydrogel may provide significant advantages for use in future clinical application in replacing nucleus pulposus field. Nature Publishing Group UK 2017-05-24 /pmc/articles/PMC5443820/ /pubmed/28539658 http://dx.doi.org/10.1038/s41598-017-02497-3 Text en © The Author(s) 2017 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Hu, Jingen Lu, Yang Cai, Ling Owusu-Ansah, Kwabena Gyabaah Xu, Gewen Han, Feilong Bao, Junjie Lin, Xiangjin Huang, Yiping Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title | Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title_full | Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title_fullStr | Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title_full_unstemmed | Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title_short | Functional compressive mechanics and tissue biocompatibility of an injectable SF/PU hydrogel for nucleus pulposus replacement |
title_sort | functional compressive mechanics and tissue biocompatibility of an injectable sf/pu hydrogel for nucleus pulposus replacement |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5443820/ https://www.ncbi.nlm.nih.gov/pubmed/28539658 http://dx.doi.org/10.1038/s41598-017-02497-3 |
work_keys_str_mv | AT hujingen functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT luyang functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT cailing functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT owusuansahkwabenagyabaah functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT xugewen functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT hanfeilong functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT baojunjie functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT linxiangjin functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement AT huangyiping functionalcompressivemechanicsandtissuebiocompatibilityofaninjectablesfpuhydrogelfornucleuspulposusreplacement |