Cargando…
An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis
A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444014/ https://www.ncbi.nlm.nih.gov/pubmed/28584518 http://dx.doi.org/10.1155/2017/7595642 |
_version_ | 1783238660399824896 |
---|---|
author | Bhuiyan, M. S. H. Choudhury, I. A. Dahari, M. Nukman, Y. Dawal, S. Z. |
author_facet | Bhuiyan, M. S. H. Choudhury, I. A. Dahari, M. Nukman, Y. Dawal, S. Z. |
author_sort | Bhuiyan, M. S. H. |
collection | PubMed |
description | A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e−004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb. |
format | Online Article Text |
id | pubmed-5444014 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-54440142017-06-05 An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis Bhuiyan, M. S. H. Choudhury, I. A. Dahari, M. Nukman, Y. Dawal, S. Z. Appl Bionics Biomech Research Article A gear-based knee joint is designed to improve the performance of mechanical-type above-knee prostheses. The gear set with the help of some bracing, and bracket arrangement, is used to enable the prosthesis to follow the residual limb movement. The motion analysis and finite-element analysis (FEA) of knee joint components are carried out to assess the feasibility of the design. The maximum stress of 29.74 MPa and maximum strain of 2.393e−004 are obtained in the gear, whereas the maximum displacement of 7.975 mm occurred in the stopper of the knee arrangement. The factor of safety of 3.5 obtained from the FE analysis indicated no possibility of design failure. The results obtained from the FE analysis are then compared with the real data obtained from the literature for a similar subject. The pattern of motion analysis results has shown a great resemblance with the gait cycle of a healthy biological limb. Hindawi 2017 2017-05-05 /pmc/articles/PMC5444014/ /pubmed/28584518 http://dx.doi.org/10.1155/2017/7595642 Text en Copyright © 2017 M. S. H. Bhuiyan et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bhuiyan, M. S. H. Choudhury, I. A. Dahari, M. Nukman, Y. Dawal, S. Z. An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title | An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title_full | An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title_fullStr | An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title_full_unstemmed | An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title_short | An Investigation into a Gear-Based Knee Joint Designed for Lower Limb Prosthesis |
title_sort | investigation into a gear-based knee joint designed for lower limb prosthesis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444014/ https://www.ncbi.nlm.nih.gov/pubmed/28584518 http://dx.doi.org/10.1155/2017/7595642 |
work_keys_str_mv | AT bhuiyanmsh aninvestigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT choudhuryia aninvestigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT daharim aninvestigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT nukmany aninvestigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT dawalsz aninvestigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT bhuiyanmsh investigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT choudhuryia investigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT daharim investigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT nukmany investigationintoagearbasedkneejointdesignedforlowerlimbprosthesis AT dawalsz investigationintoagearbasedkneejointdesignedforlowerlimbprosthesis |