Cargando…
Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium
A reflectance confocal endomicroscope with double-clad fiber coupler and electrically tunable focus lens is applied to imaging of the oral mucosa. The instrument is designed to be lightweight and robust for clinical use. The tunable lens allows axial scanning through [Formula: see text] in the epith...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Society of Photo-Optical Instrumentation Engineers
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444308/ https://www.ncbi.nlm.nih.gov/pubmed/28541447 http://dx.doi.org/10.1117/1.JBO.22.5.056008 |
_version_ | 1783238695250296832 |
---|---|
author | Olsovsky, Cory Hinsdale, Taylor Cuenca, Rodrigo Cheng, Yi-Shing Lisa Wright, John M. Rees, Terry D. Jo, Javier A. Maitland, Kristen C. |
author_facet | Olsovsky, Cory Hinsdale, Taylor Cuenca, Rodrigo Cheng, Yi-Shing Lisa Wright, John M. Rees, Terry D. Jo, Javier A. Maitland, Kristen C. |
author_sort | Olsovsky, Cory |
collection | PubMed |
description | A reflectance confocal endomicroscope with double-clad fiber coupler and electrically tunable focus lens is applied to imaging of the oral mucosa. The instrument is designed to be lightweight and robust for clinical use. The tunable lens allows axial scanning through [Formula: see text] in the epithelium when the probe tip is placed in contact with tissue. Images are acquired at 6.6 frames per second with a field of view diameter up to [Formula: see text]. In vivo imaging of a wide range of normal sites in the oral cavity demonstrates the accessibility of the handheld probe. In vivo imaging of clinical lesions diagnosed as inflammation and dysplasia illustrates the ability of reflectance confocal endomicroscopy to image cellular changes associated with pathology. |
format | Online Article Text |
id | pubmed-5444308 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Society of Photo-Optical Instrumentation Engineers |
record_format | MEDLINE/PubMed |
spelling | pubmed-54443082018-05-25 Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium Olsovsky, Cory Hinsdale, Taylor Cuenca, Rodrigo Cheng, Yi-Shing Lisa Wright, John M. Rees, Terry D. Jo, Javier A. Maitland, Kristen C. J Biomed Opt Research Papers: Imaging A reflectance confocal endomicroscope with double-clad fiber coupler and electrically tunable focus lens is applied to imaging of the oral mucosa. The instrument is designed to be lightweight and robust for clinical use. The tunable lens allows axial scanning through [Formula: see text] in the epithelium when the probe tip is placed in contact with tissue. Images are acquired at 6.6 frames per second with a field of view diameter up to [Formula: see text]. In vivo imaging of a wide range of normal sites in the oral cavity demonstrates the accessibility of the handheld probe. In vivo imaging of clinical lesions diagnosed as inflammation and dysplasia illustrates the ability of reflectance confocal endomicroscopy to image cellular changes associated with pathology. Society of Photo-Optical Instrumentation Engineers 2017-05-25 2017-05 /pmc/articles/PMC5444308/ /pubmed/28541447 http://dx.doi.org/10.1117/1.JBO.22.5.056008 Text en © The Authors. https://creativecommons.org/licenses/by/3.0/ Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. |
spellingShingle | Research Papers: Imaging Olsovsky, Cory Hinsdale, Taylor Cuenca, Rodrigo Cheng, Yi-Shing Lisa Wright, John M. Rees, Terry D. Jo, Javier A. Maitland, Kristen C. Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title | Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title_full | Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title_fullStr | Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title_full_unstemmed | Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title_short | Handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
title_sort | handheld tunable focus confocal microscope utilizing a double-clad fiber coupler for in vivo imaging of oral epithelium |
topic | Research Papers: Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444308/ https://www.ncbi.nlm.nih.gov/pubmed/28541447 http://dx.doi.org/10.1117/1.JBO.22.5.056008 |
work_keys_str_mv | AT olsovskycory handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT hinsdaletaylor handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT cuencarodrigo handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT chengyishinglisa handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT wrightjohnm handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT reesterryd handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT jojaviera handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium AT maitlandkristenc handheldtunablefocusconfocalmicroscopeutilizingadoublecladfibercouplerforinvivoimagingoforalepithelium |