Cargando…

The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss

BACKGROUND: Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialys...

Descripción completa

Detalles Bibliográficos
Autores principales: Amdisen, Chris, Jespersen, Bente, Møldrup, Ulla, Keller, Anna K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444816/
https://www.ncbi.nlm.nih.gov/pubmed/28542429
http://dx.doi.org/10.1371/journal.pone.0178301
_version_ 1783238772477919232
author Amdisen, Chris
Jespersen, Bente
Møldrup, Ulla
Keller, Anna K.
author_facet Amdisen, Chris
Jespersen, Bente
Møldrup, Ulla
Keller, Anna K.
author_sort Amdisen, Chris
collection PubMed
description BACKGROUND: Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion. METHODS: In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls. RESULTS: All parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed. CONCLUSIONS: We developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended.
format Online
Article
Text
id pubmed-5444816
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-54448162017-06-12 The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss Amdisen, Chris Jespersen, Bente Møldrup, Ulla Keller, Anna K. PLoS One Research Article BACKGROUND: Vascular occlusion is a rare, but serious complication after kidney transplantation often resulting in graft loss. We therefore aimed to develop an experimental porcine model for stepwise reduction of the renal venous blood flow and to compare an implantable Doppler probe and microdialysis for fast detection of vascular occlusion. METHODS: In 20 pigs, implantable Doppler probes were placed on the renal artery and vein and a microdialysis catheter was placed in the renal cortex. An arterial flowprobe served as gold standard. Following two-hour baseline measurements, the pigs were randomised to stepwise venous occlusion, complete venous occlusion, complete arterial occlusion or controls. RESULTS: All parameters were stable through baseline measurements. Glutamate and lactate measured by microdialysis increased significantly (p = 0.02 and p = 0.03 respectively) 30 minutes after a 2/3 (66%) reduction in renal blood flow. The implantable Doppler probe was not able to detect flow changes until there was total venous occlusion. Microdialysis detected changes in local metabolism after both arterial and venous occlusion; the implantable Doppler probe could only detect vascular occlusions on the vessel it was placed. CONCLUSIONS: We developed a new model for stepwise renal venous blood flow occlusion. Furthermore, the first comparison of the implantable Doppler probe and microdialysis for detection of renal vascular occlusions was made. The implantable Doppler probe could only detect flow changes after a complete occlusion, whereas microdialysis detected changes earlier, and could detect both arterial and venous occlusion. Based on these results, the implantable Doppler probe for early detection of vascular occlusions cannot be recommended. Public Library of Science 2017-05-25 /pmc/articles/PMC5444816/ /pubmed/28542429 http://dx.doi.org/10.1371/journal.pone.0178301 Text en © 2017 Amdisen et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Amdisen, Chris
Jespersen, Bente
Møldrup, Ulla
Keller, Anna K.
The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title_full The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title_fullStr The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title_full_unstemmed The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title_short The unsuitability of implantable Doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
title_sort unsuitability of implantable doppler probes for the early detection of renal vascular complications – a porcine model for prevention of renal transplant loss
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5444816/
https://www.ncbi.nlm.nih.gov/pubmed/28542429
http://dx.doi.org/10.1371/journal.pone.0178301
work_keys_str_mv AT amdisenchris theunsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT jespersenbente theunsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT møldrupulla theunsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT kellerannak theunsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT amdisenchris unsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT jespersenbente unsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT møldrupulla unsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss
AT kellerannak unsuitabilityofimplantabledopplerprobesfortheearlydetectionofrenalvascularcomplicationsaporcinemodelforpreventionofrenaltransplantloss