Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study
PURPOSE: Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX). METHODS: The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual i...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5445413/ https://www.ncbi.nlm.nih.gov/pubmed/28545556 http://dx.doi.org/10.1186/s13014-017-0826-8 |
_version_ | 1783238884453253120 |
---|---|
author | Bratengeier, Klaus Herzog, Barbara Wegener, Sonja Holubyev, Kostyantyn |
author_facet | Bratengeier, Klaus Herzog, Barbara Wegener, Sonja Holubyev, Kostyantyn |
author_sort | Bratengeier, Klaus |
collection | PubMed |
description | PURPOSE: Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX). METHODS: The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual isocentre distance (SVID) in contrast to normal source to isocentre distance (SID) for stereotactic applications. The role of MLC leaf width and 20–80% penumbra was examined concerning the healthy tissue sparing. Several prescription schemes and target diameters are considered. RESULTS: Paddick’s gradient index (GI) as well as comparison of the mean doses to spherical shells at several distances to the target is evaluated. Both emphasize the same results: the healthy tissue sparing in the high dose area around the planning target volume (PTV) is improved at reduced SVID ≤ 70 cm. The effect can be attributed more to steeper penumbra than to finer leaf resolution. Comparing circular collimators at different SVID just as MLC-shaped collimators, always the GI was reduced. Even MLC-shaped collimator at SVID 70 cm had better healthy tissue sparing than an optimal shaped circular collimator at SID 100 cm. Regarding penumbra changes due to varying SVID, the results of the planning study are underlined by film dosimetry measurements with Agility™ MLC. CONCLUSION: Penumbra requires more attention in comparing studies, especially studies using different planning systems. Reduced SVID probably allows usage of conventional MLC for STX-like irradiations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-017-0826-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5445413 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-54454132017-05-30 Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study Bratengeier, Klaus Herzog, Barbara Wegener, Sonja Holubyev, Kostyantyn Radiat Oncol Research PURPOSE: Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX). METHODS: The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual isocentre distance (SVID) in contrast to normal source to isocentre distance (SID) for stereotactic applications. The role of MLC leaf width and 20–80% penumbra was examined concerning the healthy tissue sparing. Several prescription schemes and target diameters are considered. RESULTS: Paddick’s gradient index (GI) as well as comparison of the mean doses to spherical shells at several distances to the target is evaluated. Both emphasize the same results: the healthy tissue sparing in the high dose area around the planning target volume (PTV) is improved at reduced SVID ≤ 70 cm. The effect can be attributed more to steeper penumbra than to finer leaf resolution. Comparing circular collimators at different SVID just as MLC-shaped collimators, always the GI was reduced. Even MLC-shaped collimator at SVID 70 cm had better healthy tissue sparing than an optimal shaped circular collimator at SID 100 cm. Regarding penumbra changes due to varying SVID, the results of the planning study are underlined by film dosimetry measurements with Agility™ MLC. CONCLUSION: Penumbra requires more attention in comparing studies, especially studies using different planning systems. Reduced SVID probably allows usage of conventional MLC for STX-like irradiations. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13014-017-0826-8) contains supplementary material, which is available to authorized users. BioMed Central 2017-05-25 /pmc/articles/PMC5445413/ /pubmed/28545556 http://dx.doi.org/10.1186/s13014-017-0826-8 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Bratengeier, Klaus Herzog, Barbara Wegener, Sonja Holubyev, Kostyantyn Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title | Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title_full | Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title_fullStr | Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title_full_unstemmed | Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title_short | Finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to PTV-shaped collimators in standard distance – a planning study |
title_sort | finer leaf resolution and steeper beam edges using a virtual isocentre in concurrence to ptv-shaped collimators in standard distance – a planning study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5445413/ https://www.ncbi.nlm.nih.gov/pubmed/28545556 http://dx.doi.org/10.1186/s13014-017-0826-8 |
work_keys_str_mv | AT bratengeierklaus finerleafresolutionandsteeperbeamedgesusingavirtualisocentreinconcurrencetoptvshapedcollimatorsinstandarddistanceaplanningstudy AT herzogbarbara finerleafresolutionandsteeperbeamedgesusingavirtualisocentreinconcurrencetoptvshapedcollimatorsinstandarddistanceaplanningstudy AT wegenersonja finerleafresolutionandsteeperbeamedgesusingavirtualisocentreinconcurrencetoptvshapedcollimatorsinstandarddistanceaplanningstudy AT holubyevkostyantyn finerleafresolutionandsteeperbeamedgesusingavirtualisocentreinconcurrencetoptvshapedcollimatorsinstandarddistanceaplanningstudy |