Cargando…

Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes

INTRODUCTION: Published evaluations of sensor glucose monitoring use in insulin treated type 2 diabetes are limited. The aim of this study was to assess the impact of flash glucose-sensing technology as a replacement for self-monitoring of blood glucose (SMBG) over a 12-month period in participants...

Descripción completa

Detalles Bibliográficos
Autores principales: Haak, Thomas, Hanaire, Hélène, Ajjan, Ramzi, Hermanns, Norbert, Riveline, Jean-Pierre, Rayman, Gerry
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5446381/
https://www.ncbi.nlm.nih.gov/pubmed/28401454
http://dx.doi.org/10.1007/s13300-017-0255-6
_version_ 1783239056204759040
author Haak, Thomas
Hanaire, Hélène
Ajjan, Ramzi
Hermanns, Norbert
Riveline, Jean-Pierre
Rayman, Gerry
author_facet Haak, Thomas
Hanaire, Hélène
Ajjan, Ramzi
Hermanns, Norbert
Riveline, Jean-Pierre
Rayman, Gerry
author_sort Haak, Thomas
collection PubMed
description INTRODUCTION: Published evaluations of sensor glucose monitoring use in insulin treated type 2 diabetes are limited. The aim of this study was to assess the impact of flash glucose-sensing technology as a replacement for self-monitoring of blood glucose (SMBG) over a 12-month period in participants with type 2 diabetes who were on intensive insulin therapy. METHODS: An open-label, randomized, controlled study in adults with type 2 diabetes on intensive insulin therapy from 26 European diabetes centers aimed at assessing flash glucose sensing technology was conducted. Participants (N = 224) were randomized (1:2 respectively) to a control group (n = 75) that used SMBG (FreeStyle Lite™) or to an intervention group (n = 149) which used sensor glucose data (FreeStyle Libre™ Flash Glucose Monitoring System) for self-management over 6 months. All intervention group participants who completed the 6-month treatment phase continued into an additional 6-month open-access phase. RESULTS: A total of 139 intervention participants completed the 6-month treatment phase and continued into the open-access phase. At 12 months (end of open-access period), time in hypoglycemia [sensor glucose <3.9 mmol/L (70 mg/dL)] was reduced by 50% compared to baseline [−0.70 ± 1.85/24 h (mean ± standard deviation); p = 0.0002]. Nocturnal hypoglycemia [2300 to 0600 hours, <3.9 mmol/L (70 mg/dL)] was reduced by 52%; p = 0.0002. There was no change in time in range [sensor glucose 3.9–10.0 mmol/L (70–180 mg/dL)]. SMBG testing fell from a mean of 3.9 (median 3.9) times/day at baseline to 0.2 (0.0), with an average frequency of sensor scanning of 7.1 (5.7) times/day at 12 months, and mean sensor utilization was 83.6 ± 13.8% (median 88.3%) during the open-access phase. During this 6-month extension period no device-related serious adverse events were reported. Nine participants reported 16 instances of device-related adverse events (e.g. infection, allergy) and 28 participants (20.1%) experienced 134 occurrences of anticipated skin symptoms/sensor-insertion events expected with device use (e.g. erythema, itching and rash). CONCLUSION: The use of flash glucose-sensing technology for glycemic management in individuals with type 2 diabetes treated by intensive insulin therapy over 12 months was associated with a sustained reduction in hypoglycemia and safely and effectively replaced SMBG. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT02082184. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s13300-017-0255-6) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5446381
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-54463812017-06-12 Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes Haak, Thomas Hanaire, Hélène Ajjan, Ramzi Hermanns, Norbert Riveline, Jean-Pierre Rayman, Gerry Diabetes Ther Original Research INTRODUCTION: Published evaluations of sensor glucose monitoring use in insulin treated type 2 diabetes are limited. The aim of this study was to assess the impact of flash glucose-sensing technology as a replacement for self-monitoring of blood glucose (SMBG) over a 12-month period in participants with type 2 diabetes who were on intensive insulin therapy. METHODS: An open-label, randomized, controlled study in adults with type 2 diabetes on intensive insulin therapy from 26 European diabetes centers aimed at assessing flash glucose sensing technology was conducted. Participants (N = 224) were randomized (1:2 respectively) to a control group (n = 75) that used SMBG (FreeStyle Lite™) or to an intervention group (n = 149) which used sensor glucose data (FreeStyle Libre™ Flash Glucose Monitoring System) for self-management over 6 months. All intervention group participants who completed the 6-month treatment phase continued into an additional 6-month open-access phase. RESULTS: A total of 139 intervention participants completed the 6-month treatment phase and continued into the open-access phase. At 12 months (end of open-access period), time in hypoglycemia [sensor glucose <3.9 mmol/L (70 mg/dL)] was reduced by 50% compared to baseline [−0.70 ± 1.85/24 h (mean ± standard deviation); p = 0.0002]. Nocturnal hypoglycemia [2300 to 0600 hours, <3.9 mmol/L (70 mg/dL)] was reduced by 52%; p = 0.0002. There was no change in time in range [sensor glucose 3.9–10.0 mmol/L (70–180 mg/dL)]. SMBG testing fell from a mean of 3.9 (median 3.9) times/day at baseline to 0.2 (0.0), with an average frequency of sensor scanning of 7.1 (5.7) times/day at 12 months, and mean sensor utilization was 83.6 ± 13.8% (median 88.3%) during the open-access phase. During this 6-month extension period no device-related serious adverse events were reported. Nine participants reported 16 instances of device-related adverse events (e.g. infection, allergy) and 28 participants (20.1%) experienced 134 occurrences of anticipated skin symptoms/sensor-insertion events expected with device use (e.g. erythema, itching and rash). CONCLUSION: The use of flash glucose-sensing technology for glycemic management in individuals with type 2 diabetes treated by intensive insulin therapy over 12 months was associated with a sustained reduction in hypoglycemia and safely and effectively replaced SMBG. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT02082184. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s13300-017-0255-6) contains supplementary material, which is available to authorized users. Springer Healthcare 2017-04-11 2017-06 /pmc/articles/PMC5446381/ /pubmed/28401454 http://dx.doi.org/10.1007/s13300-017-0255-6 Text en © The Author(s) 2017 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Haak, Thomas
Hanaire, Hélène
Ajjan, Ramzi
Hermanns, Norbert
Riveline, Jean-Pierre
Rayman, Gerry
Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title_full Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title_fullStr Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title_full_unstemmed Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title_short Use of Flash Glucose-Sensing Technology for 12 months as a Replacement for Blood Glucose Monitoring in Insulin-treated Type 2 Diabetes
title_sort use of flash glucose-sensing technology for 12 months as a replacement for blood glucose monitoring in insulin-treated type 2 diabetes
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5446381/
https://www.ncbi.nlm.nih.gov/pubmed/28401454
http://dx.doi.org/10.1007/s13300-017-0255-6
work_keys_str_mv AT haakthomas useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes
AT hanairehelene useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes
AT ajjanramzi useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes
AT hermannsnorbert useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes
AT rivelinejeanpierre useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes
AT raymangerry useofflashglucosesensingtechnologyfor12monthsasareplacementforbloodglucosemonitoringininsulintreatedtype2diabetes