Cargando…

A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach

INTRODUCTION: Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monit...

Descripción completa

Detalles Bibliográficos
Autores principales: Christiansen, Sverre Christian, Fougner, Anders Lyngvi, Stavdahl, Øyvind, Kölle, Konstanze, Ellingsen, Reinold, Carlsen, Sven Magnus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5446388/
https://www.ncbi.nlm.nih.gov/pubmed/28503717
http://dx.doi.org/10.1007/s13300-017-0263-6
_version_ 1783239058739167232
author Christiansen, Sverre Christian
Fougner, Anders Lyngvi
Stavdahl, Øyvind
Kölle, Konstanze
Ellingsen, Reinold
Carlsen, Sven Magnus
author_facet Christiansen, Sverre Christian
Fougner, Anders Lyngvi
Stavdahl, Øyvind
Kölle, Konstanze
Ellingsen, Reinold
Carlsen, Sven Magnus
author_sort Christiansen, Sverre Christian
collection PubMed
description INTRODUCTION: Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion. Few have focused on the fundamental limitations of this approach, especially regarding outcome measures beyond time in range. METHODS: Based on insulin physiology, the limitations of CGM, SC insulin absorption, meal challenge, and physical activity in DM1 patients, we discuss the limitations of the double SC approach. Finally, we discuss safety measures and the achievements reported in some recent AP studies that have utilized the double SC approach. RESULTS: Most studies show that a double SC AP increases the time in range compared to a sensor-augmented insulin pump and shortens the time in hypoglycemia. Despite these achievements, the proportion of time spent in hyperglycemia is still roughly 20–40%, and hypoglycemia is still present 1–4% of the time. The main factors limiting further progress are the latency of SC CGM (at least 5–10 min) and the slow pharmacokinetics of SC-delivered fast-acting insulin. The maximum blood insulin level is reached after 45 min and the maximum glucose-lowering effect is observed after 1.5–2 h, while the glucose-lowering effect lasts for at least 5 h. CONCLUSIONS: Although using a double SC AP leads to significant improvements in glucose control, the SC approach has severe limitations that hamper further progress towards a robust AP.
format Online
Article
Text
id pubmed-5446388
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-54463882017-06-12 A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach Christiansen, Sverre Christian Fougner, Anders Lyngvi Stavdahl, Øyvind Kölle, Konstanze Ellingsen, Reinold Carlsen, Sven Magnus Diabetes Ther Review INTRODUCTION: Patients with diabetes type 1 (DM1) struggle daily to achieve good glucose control. The last decade has seen a rush of research groups working towards an artificial pancreas (AP) through the application of a double subcutaneous approach, i.e., subcutaneous (SC) continuous glucose monitoring (CGM) and continuous subcutaneous insulin infusion. Few have focused on the fundamental limitations of this approach, especially regarding outcome measures beyond time in range. METHODS: Based on insulin physiology, the limitations of CGM, SC insulin absorption, meal challenge, and physical activity in DM1 patients, we discuss the limitations of the double SC approach. Finally, we discuss safety measures and the achievements reported in some recent AP studies that have utilized the double SC approach. RESULTS: Most studies show that a double SC AP increases the time in range compared to a sensor-augmented insulin pump and shortens the time in hypoglycemia. Despite these achievements, the proportion of time spent in hyperglycemia is still roughly 20–40%, and hypoglycemia is still present 1–4% of the time. The main factors limiting further progress are the latency of SC CGM (at least 5–10 min) and the slow pharmacokinetics of SC-delivered fast-acting insulin. The maximum blood insulin level is reached after 45 min and the maximum glucose-lowering effect is observed after 1.5–2 h, while the glucose-lowering effect lasts for at least 5 h. CONCLUSIONS: Although using a double SC AP leads to significant improvements in glucose control, the SC approach has severe limitations that hamper further progress towards a robust AP. Springer Healthcare 2017-05-13 2017-06 /pmc/articles/PMC5446388/ /pubmed/28503717 http://dx.doi.org/10.1007/s13300-017-0263-6 Text en © The Author(s) 2017 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Review
Christiansen, Sverre Christian
Fougner, Anders Lyngvi
Stavdahl, Øyvind
Kölle, Konstanze
Ellingsen, Reinold
Carlsen, Sven Magnus
A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title_full A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title_fullStr A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title_full_unstemmed A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title_short A Review of the Current Challenges Associated with the Development of an Artificial Pancreas by a Double Subcutaneous Approach
title_sort review of the current challenges associated with the development of an artificial pancreas by a double subcutaneous approach
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5446388/
https://www.ncbi.nlm.nih.gov/pubmed/28503717
http://dx.doi.org/10.1007/s13300-017-0263-6
work_keys_str_mv AT christiansensverrechristian areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT fougneranderslyngvi areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT stavdahløyvind areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT kollekonstanze areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT ellingsenreinold areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT carlsensvenmagnus areviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT christiansensverrechristian reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT fougneranderslyngvi reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT stavdahløyvind reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT kollekonstanze reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT ellingsenreinold reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach
AT carlsensvenmagnus reviewofthecurrentchallengesassociatedwiththedevelopmentofanartificialpancreasbyadoublesubcutaneousapproach