Cargando…
Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases
OBJECTIVE: To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm im...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5447646/ https://www.ncbi.nlm.nih.gov/pubmed/28670165 http://dx.doi.org/10.3348/kjr.2017.18.4.699 |
_version_ | 1783239375291678720 |
---|---|
author | Bae, Yun Jung Choi, Byung Se Lee, Kyung Mi Yoon, Yeon Hong Sunwoo, Leonard Jung, Cheolkyu Kim, Jae Hyoung |
author_facet | Bae, Yun Jung Choi, Byung Se Lee, Kyung Mi Yoon, Yeon Hong Sunwoo, Leonard Jung, Cheolkyu Kim, Jae Hyoung |
author_sort | Bae, Yun Jung |
collection | PubMed |
description | OBJECTIVE: To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging (non-MIP 3D-GRE), and 5-mm MIP 3D-GRE. MATERIALS AND METHODS: From October 2014 to July 2015, 30 patients with 460 enhancing brain metastases (size > 3 mm, n = 150; size ≤ 3 mm, n = 310) were scanned with non-MIP iMSDE-TSE and non-MIP 3D-GRE. We then performed 5-mm MIP reconstruction of these images. Two independent neuroradiologists reviewed these four sequences. Their diagnostic performance was compared using the following parameters: sensitivity, reading time, and figure of merit (FOM) derived by jackknife alternative free-response receiver operating characteristic analysis. Interobserver agreement was also tested. RESULTS: The mean FOM (all lesions, 0.984; lesions ≤ 3 mm, 0.980) and sensitivity ([reader 1: all lesions, 97.3%; lesions ≤ 3 mm, 96.2%], [reader 2: all lesions, 97.0%; lesions ≤ 3 mm, 95.8%]) of MIP iMSDE-TSE was comparable to the mean FOM (0.985, 0.977) and sensitivity ([reader 1: 96.7, 99.0%], [reader 2: 97, 95.3%]) of non-MIP iMSDE-TSE, but they were superior to those of non-MIP and MIP 3D-GREs (all, p < 0.001). The reading time of MIP iMSDE-TSE (reader 1: 47.7 ± 35.9 seconds; reader 2: 44.7 ± 23.6 seconds) was significantly shorter than that of non-MIP iMSDE-TSE (reader 1: 78.8 ± 43.7 seconds, p = 0.01; reader 2: 82.9 ± 39.9 seconds, p < 0.001). Interobserver agreement was excellent (κ > 0.75) for all lesions in both sequences. CONCLUSION: MIP iMSDE-TSE showed high detectability of brain metastases. Its detectability was comparable to that of non-MIP iMSDE-TSE, but it was superior to the detectability of non-MIP/MIP 3D-GREs. With a shorter reading time, the false-positive results of MIP iMSDE-TSE were greater. We suggest that MIP iMSDE-TSE can provide high diagnostic performance and low false-positive rates when combined with 1-mm sequences. |
format | Online Article Text |
id | pubmed-5447646 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-54476462017-07-01 Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases Bae, Yun Jung Choi, Byung Se Lee, Kyung Mi Yoon, Yeon Hong Sunwoo, Leonard Jung, Cheolkyu Kim, Jae Hyoung Korean J Radiol Neuroimaging and Head & Neck OBJECTIVE: To evaluate the diagnostic benefits of 5-mm maximum intensity projection of improved motion-sensitized driven-equilibrium prepared contrast-enhanced 3D T1-weighted turbo-spin echo imaging (MIP iMSDE-TSE) in the detection of brain metastases. The imaging technique was compared with 1-mm images of iMSDE-TSE (non-MIP iMSDE-TSE), 1-mm contrast-enhanced 3D T1-weighted gradient-echo imaging (non-MIP 3D-GRE), and 5-mm MIP 3D-GRE. MATERIALS AND METHODS: From October 2014 to July 2015, 30 patients with 460 enhancing brain metastases (size > 3 mm, n = 150; size ≤ 3 mm, n = 310) were scanned with non-MIP iMSDE-TSE and non-MIP 3D-GRE. We then performed 5-mm MIP reconstruction of these images. Two independent neuroradiologists reviewed these four sequences. Their diagnostic performance was compared using the following parameters: sensitivity, reading time, and figure of merit (FOM) derived by jackknife alternative free-response receiver operating characteristic analysis. Interobserver agreement was also tested. RESULTS: The mean FOM (all lesions, 0.984; lesions ≤ 3 mm, 0.980) and sensitivity ([reader 1: all lesions, 97.3%; lesions ≤ 3 mm, 96.2%], [reader 2: all lesions, 97.0%; lesions ≤ 3 mm, 95.8%]) of MIP iMSDE-TSE was comparable to the mean FOM (0.985, 0.977) and sensitivity ([reader 1: 96.7, 99.0%], [reader 2: 97, 95.3%]) of non-MIP iMSDE-TSE, but they were superior to those of non-MIP and MIP 3D-GREs (all, p < 0.001). The reading time of MIP iMSDE-TSE (reader 1: 47.7 ± 35.9 seconds; reader 2: 44.7 ± 23.6 seconds) was significantly shorter than that of non-MIP iMSDE-TSE (reader 1: 78.8 ± 43.7 seconds, p = 0.01; reader 2: 82.9 ± 39.9 seconds, p < 0.001). Interobserver agreement was excellent (κ > 0.75) for all lesions in both sequences. CONCLUSION: MIP iMSDE-TSE showed high detectability of brain metastases. Its detectability was comparable to that of non-MIP iMSDE-TSE, but it was superior to the detectability of non-MIP/MIP 3D-GREs. With a shorter reading time, the false-positive results of MIP iMSDE-TSE were greater. We suggest that MIP iMSDE-TSE can provide high diagnostic performance and low false-positive rates when combined with 1-mm sequences. The Korean Society of Radiology 2017 2017-05-19 /pmc/articles/PMC5447646/ /pubmed/28670165 http://dx.doi.org/10.3348/kjr.2017.18.4.699 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Neuroimaging and Head & Neck Bae, Yun Jung Choi, Byung Se Lee, Kyung Mi Yoon, Yeon Hong Sunwoo, Leonard Jung, Cheolkyu Kim, Jae Hyoung Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title | Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title_full | Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title_fullStr | Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title_full_unstemmed | Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title_short | Efficacy of Maximum Intensity Projection of Contrast-Enhanced 3D Turbo-Spin Echo Imaging with Improved Motion-Sensitized Driven-Equilibrium Preparation in the Detection of Brain Metastases |
title_sort | efficacy of maximum intensity projection of contrast-enhanced 3d turbo-spin echo imaging with improved motion-sensitized driven-equilibrium preparation in the detection of brain metastases |
topic | Neuroimaging and Head & Neck |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5447646/ https://www.ncbi.nlm.nih.gov/pubmed/28670165 http://dx.doi.org/10.3348/kjr.2017.18.4.699 |
work_keys_str_mv | AT baeyunjung efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT choibyungse efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT leekyungmi efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT yoonyeonhong efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT sunwooleonard efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT jungcheolkyu efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases AT kimjaehyoung efficacyofmaximumintensityprojectionofcontrastenhanced3dturbospinechoimagingwithimprovedmotionsensitizeddrivenequilibriumpreparationinthedetectionofbrainmetastases |