Cargando…

The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds

Restoration of segmental defects in long bones remains a challenging task in orthopedic surgery. Although autologous bone is still the ‘Gold Standard’ because of its high biocompatibility, it has nevertheless been associated with several disadvantages. Consequently, artificial materials, such as cal...

Descripción completa

Detalles Bibliográficos
Autores principales: Wieding, Jan, Jonitz, Anika, Bader, Rainer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5448937/
http://dx.doi.org/10.3390/ma5081336
_version_ 1783239663109013504
author Wieding, Jan
Jonitz, Anika
Bader, Rainer
author_facet Wieding, Jan
Jonitz, Anika
Bader, Rainer
author_sort Wieding, Jan
collection PubMed
description Restoration of segmental defects in long bones remains a challenging task in orthopedic surgery. Although autologous bone is still the ‘Gold Standard’ because of its high biocompatibility, it has nevertheless been associated with several disadvantages. Consequently, artificial materials, such as calcium phosphate and titanium, have been considered for the treatment of bone defects. In the present study, the mechanical properties of three different scaffold designs were investigated. The scaffolds were made of titanium alloy (Ti6Al4V), fabricated by means of an additive manufacturing process with defined pore geometry and porosities of approximately 70%. Two scaffolds exhibited rectangular struts, orientated in the direction of loading. The struts for the third scaffold were orientated diagonal to the load direction, and featured a circular cross-section. Material properties were calculated from stress-strain relationships under axial compression testing. In vitro cell testing was undertaken with human osteoblasts on scaffolds fabricated using the same manufacturing process. Although the scaffolds exhibited different strut geometry, the mechanical properties of ultimate compressive strength were similar (145–164 MPa) and in the range of human cortical bone. Test results for elastic modulus revealed values between 3.7 and 6.7 GPa. In vitro testing demonstrated proliferation and spreading of bone cells on the scaffold surface.
format Online
Article
Text
id pubmed-5448937
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-54489372017-07-28 The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds Wieding, Jan Jonitz, Anika Bader, Rainer Materials (Basel) Article Restoration of segmental defects in long bones remains a challenging task in orthopedic surgery. Although autologous bone is still the ‘Gold Standard’ because of its high biocompatibility, it has nevertheless been associated with several disadvantages. Consequently, artificial materials, such as calcium phosphate and titanium, have been considered for the treatment of bone defects. In the present study, the mechanical properties of three different scaffold designs were investigated. The scaffolds were made of titanium alloy (Ti6Al4V), fabricated by means of an additive manufacturing process with defined pore geometry and porosities of approximately 70%. Two scaffolds exhibited rectangular struts, orientated in the direction of loading. The struts for the third scaffold were orientated diagonal to the load direction, and featured a circular cross-section. Material properties were calculated from stress-strain relationships under axial compression testing. In vitro cell testing was undertaken with human osteoblasts on scaffolds fabricated using the same manufacturing process. Although the scaffolds exhibited different strut geometry, the mechanical properties of ultimate compressive strength were similar (145–164 MPa) and in the range of human cortical bone. Test results for elastic modulus revealed values between 3.7 and 6.7 GPa. In vitro testing demonstrated proliferation and spreading of bone cells on the scaffold surface. MDPI 2012-08-10 /pmc/articles/PMC5448937/ http://dx.doi.org/10.3390/ma5081336 Text en © 2012 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Wieding, Jan
Jonitz, Anika
Bader, Rainer
The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title_full The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title_fullStr The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title_full_unstemmed The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title_short The Effect of Structural Design on Mechanical Properties and Cellular Response of Additive Manufactured Titanium Scaffolds
title_sort effect of structural design on mechanical properties and cellular response of additive manufactured titanium scaffolds
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5448937/
http://dx.doi.org/10.3390/ma5081336
work_keys_str_mv AT wiedingjan theeffectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds
AT jonitzanika theeffectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds
AT baderrainer theeffectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds
AT wiedingjan effectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds
AT jonitzanika effectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds
AT baderrainer effectofstructuraldesignonmechanicalpropertiesandcellularresponseofadditivemanufacturedtitaniumscaffolds